Fluke 1750 Three-Phase Power Recorder Technical Data Never miss capturing a disturbance--with the exclusive threshold-free measurement system, it's automatic. Capture every measurement, every event, on every cycle, all the time with the Fluke 1750 Power Recorder. Outstanding accuracy and resolution provide complete visibility into your installation or distribution system. * Power quality that meets the standard: * * * All measurements comply with IEC61000-4-30 standards for correct evaluation of all measured values including voltage, current, power, harmonics, flicker etc. Quick and reliable configuration: PDA wireless "front panel interface" provides the ability to verify setup without a laptop along with a window into what the instrument is recording, even in awkward test locations. Threshold-free setup: Apply thresholds after data is collected with Fluke Power Analyze Software so there is no need to worry about missed information due to incorrect set-up. Captures everything: Cross-channel and current triggering capture every measurement, on every channel, every time. * Intuitive PC software: Easily analyze data and * * * * * generate reports. Automated EN50160 reporting and compliance. Plug and play: Set up in minutes with selfidentifying current probes and single-lead voltage connections. No need to reconnect wires: Swap channels internally with the wireless PDA or PC when connections are not correct. Measure every parameter: voltage and current on three phases, neutral, and ground. 5 MHz, 8000 Vpk waveform capture: Get a detailed picture of even the shortest events. Quickly retrieve data: With included SD memory card or via the 100BaseT high-speed Ethernet connection. Applications Long-term analysis: Uncover hard-to-find or intermittent issues; monitor critical equipment, capturing power quality events to correlate with equipment malfunction Power quality surveys: Quantify power quality throughout a facility, documenting results with professional reports Quality of service compliance: Validate incoming power quality at the service entrance Equipment Installation/Commissioning: Benchmark power system prior to install to insure quality of service Easy to use The recorder automatically detects, scales, and powers current probes without needing batteries. Requiring only single-lead voltage connections enables safe and quick setups. Once power is applied the instrument automatically begins recording and LEDs give you assurance that the recorder is powered up and signals are within range - no more uncertainty that data is being recorded. The Fluke 1750 has an exclusive capture algorithm which makes certain all events are captured without the tedious setups and blind spots associated with threshold driven equipment. The PDA wirelessly interfaces with the recorder, allowing quick setup and verification with waveform displays, meter screens, and phasor diagrams. The built-in wireless technology allows you to control multiple instruments from a distance easily, without the need for a laptop computer (laptops can also be used when desired). View measurements real-time with wireless PDA interface. 2 Fluke Corporation Configurations are simple with wiring diagrams to guide you. Fluke 1750 Three-Phase Power Recorder No need to reconnect wires--swap channels internally using the PDA interface. Comprehensive power system data Every cycle on every channel is simultaneously sampled providing complete analysis of power quality, harmonics, power and energy. Crosschannel current and voltage triggering captures event data on all input channels simultaneously, no matter which channel triggered the event. When periodic analysis of the waveform may be needed, the Snapshot mode captures waveforms at userdefined intervals. Even dc signals can be recorded! Events can be displayed against a variety of tolerance curves. Full FFT on each channel to the 50th harmonic. Display multiple parameters simultaneously on one graph. Full-featured power meter display for each channel and totals. Thresholds for the EN50160 report are easily customized. EN50160 report delivers an easy to read pass or fail chart along with drill down data. Powerful data management card without using your laptop, or transfer directly to your computer via Ethernet, using TCP/IP protocol. Voice, data, and picture annotations can be made via the PDA to flag important points in the data stream. Imagine being able to flag in your recorded data when a transfer switch was operated, or load changes were made. Data is automatically stored on the internal flash memory that can store records for over a month without compression or overwriting. Data is retrieved via one of two quick and easy options: download the data onto the included SD memory 3 Fluke Corporation Fluke 1750 Three-Phase Power Recorder View data the way you want The new Fluke Power Analyze software revolutionizes your ability to analyze data. No need to worry about thresholds--with Fluke Power Analyze, thresholds can be modified after the data is recorded! And the easy-to-use user interface will display voltage as a phase-to-phase or phase-toneutral reading. Apply thresholds to data after collection using a variety of standard or customized templates. All the latest power quality standards are built-in IEC 61000-4-30 compliant measurement systems provide the confidence that all parameters are measured and calculated consistently with international standards. Automated EN50160 compliance reporting for rapid Pass/ Fail testing. Simplified report writer feature included in Fluke Power Analyze. 600 V CAT IV and 1000 V CAT III safety rating Designed to help protect you and your equipment, the Fluke 1750 Three-Phase Power Recorder and accessories are all certified to meet the stringent safety standards for use in 600 V CAT IV and 1000 V CAT III environments. They are the first tools of their kind to carry the CAT IV rating and, therefore, can be used for most power connections and for all outlets in a low-voltage power distribution system. 4 Fluke Corporation Fluke 1750 Three-Phase Power Recorder Optional Accessories Fluke power quality current transformers and flexible current probes are specially designed to work seamlessly with Fluke power monitors (1750 and 1650). All clamp-on and flexi-CT's are matched to take full advantage of your instrument's ability to set scale factors for accurate readings. Cases 1750/CASE Transit Case * Rugged water tight transit case with rollers Model No. 3005-PR 3014-PR 3140R CT Type Clamp-On Clamp-On Clamp-On Current Range 0.01 A to 5 A 0.1 A to 40 A 2 A to 400 A Accuracy 1 % RDG 0.5 % FS 1 % RDG 0.1 % FS 2 % RDG 0.04 A Frequency Response 5 kHz 5 kHz 20 kHz Jaw Opening 2 cm (.78 in) dia. 2 cm (.78 in) dia. 3.2 cm (1.25 in) dia. Model No. 3110-PR 3210-PR 3310-PR 3312-PR CT Type Flexi-CT Flexi-CT Flexi-CT Flexi-CT Current Range 2 A to 100 A 20 A to 1000 A 100 A to 5000 A 100 A to 5000 A Accuracy 1 % rdg 0.5 % FS 1 % rdg 0.15 % FS 1 % rdg 0.15 % FS 1 % rdg 0.15 % FS Frequency Response 7 kHz 7 kHz 7 kHz 7 kHz Probe Length 60 cm (24 in) 60 cm (24 in) 60 cm (24 in) 120 cm (48 in) Miscellaneous 1750/MC * Additional SD Memory Card for Fluke 1750 1750/SEAT-L * Fluke Power Analyze - Additional SEAT LICENSE * One additional license for installation on one additional PC 1750/SITE-L * Fluke Power Analyze * Additional SITE LICENSE Site license for installation on unlimited PCs 4006 Security Cable * 1.8 m (6 ft) looped lockable steel cable for securing monitor 5 Fluke Corporation Fluke 1750 Three-Phase Power Recorder Specifications for the System: Recorder and Power Analyze Software General Power quality measurement standards Conformance Clock/calendar Real-time clock accuracy Internal memory capacity for data Maximum recording period Measurement time control Maximum number of events Power requirements Operating time during interruptions IEC 61999-1-4 Class 1, IEC 61000-4-30, IEEE519, IEEE1159, IEEE1459 and EN50160 Leap years, 24-hour clock Not more than 1 s/day At least 2 GB At least 31 days Automatic Limited only by the size of the internal memory 100 to 240 V rms 10 %, 47-63 Hz, 40 W 5 minutes per interruption, 60 minutes total operating time without recharging (internal UPS operation) 215 mm x 310 mm x 35 mm (8.5 in x 12.2 in x 3.5 in) 6.3 kg (14 lb) Dimensions Mass (weight) Input Measurement types Input channels Voltage channels Current input characteristics Measuring method One Phase Plus Neutral, One Phase IT No Neutral, One Phase Split Phase, Three Phase Wye, Three Phase Delta, Three Phase IT, Three Phase High Leg, Three Phase Open Leg, 2 Element Delta, 21/2 Element Wye Voltage: 4 channels, ac/dc Current: 5 channels Input resistance: 2 M Input capacitance: < 20 pF 2 V rms = full scale, 1 M Input Impedance for ferro CTs, low impedance for Flexi-CTs Simultaneous digital sampling of voltage and current. Digital PLL synchronized sampling, internal frequency reference used during voltage drops. Synchronization and sampling PLL-synchronization source PLL lock range Sampling frequency A/D resolution The PLL synchronizes to the A-N voltage for wye power types, and to the A-B voltage for delta power types. All listed power types can be characterized as either wye or delta. 42.5 to 69 Hz Voltage and current: 256 samples/cycle Inter-harmonics per IEC 61000-4-7: 2560 points/10 cycles (50 Hz), 3072 points/12 cycles (60 Hz) Transient Voltage: 5 MHz Voltage and current: 24 bits Transient voltage: 14 bits Voltage and current measurements Voltage measurement range Voltage crest factor Current measurement range Current crest factor AC voltage: 1000 V rms 10 % over range DC voltage: 1000 V + 10 % over range 3 or less Depends on current probe used 4 or less Voltage and current measurement accuracy RMS voltage Measurement type Measurement uncertainty True rms calculated continuously: every cycle, every 1/2 cycle, and every 10 or 12 cycles at 50 or 60 Hz respectively, as required by IEC 61000-4-30. AC: 0.2 % reading 0.1 % full scale, above 50 V rms DC: 0.5 % reading 0.2 % full scale, above 50 V dc RMS current Measurement type Measurement uncertainty 6 Fluke Corporation True rms calculated continuously: every cycle, every 1/2 cycle, and every 10 or 12 cycles at 50 or 60 Hz respectively, as required by standards Ferromagnetic Clamps: (0.1 % full scale + 0.2 % reading + current sensor accuracy), valid for 5 % to 100 % of current sensor range Flexible Current Probes: (0.1 % full scale + 0.5 % reading + current sensor accuracy), valid for 5 % to 100 % of current sensor range Fluke 1750 Three-Phase Power Recorder Transient voltage (impulse) Measurement type Full scale Sample resolution Measurement uncertainty Waveshape sampling 8000 V pk 200 nS 5 % reading 20 V (test parameters: 1000 V dc, 1000 V rms, 100 kHz) Dip (Sag) and Swell Measurements Voltage swell (rms swell) Measurement type Displayed data Measurement uncertainty True rms (one cycle calculation by overlapping each half cycle - voltage between lines is measured for 3P3W lines and phase voltage is measured for 3P4W lines) Amplitude and duration of swell Same as rms voltage Voltage dip (rms sag) Measurement type Displayed data Measurement uncertainty True rms (one cycle calculation by overlapping each half cycle - voltage between lines is measured for 3P3W lines and phase voltage is measured for 3P4W lines) Amplitude and duration of dip or interruption Same as rms voltage Voltage dropout (interruption) Measurement type Same as voltage dip Power Measurements Calculated per IEEE1459 for best performance when distortion is present Measurement type True rms calculated continuously: every cycle, and every 10 or 12 cycles at 50 or 60 Hz respectively, as required by standards Measurement accuracy +/- (voltage uncertainty + current uncertainty + current probe uncertainty) Frequency Measurement range Measurement source Measurement accuracy 42.5 to 69 Hz Same as PLL synchronization source 10 mHz (10 to 110 % of range, with sine wave) Power factor Measurement range Measurement accuracy 0.000 to 1.000 1 digit from the calculation of each measured value (3 digits for total) Displacement power factor Measurement method Measurement range Measurement accuracy Calculated from the phase difference between voltage fundamental and current fundamental - 1.000 (leading) to + 1.000 (lagging) 0.5 % reading 2 % full scale 1 digit Voltage unbalance and phase sequence Measurement method Positive sequence voltage divided by negative sequence voltage, per IEC 61000-4-30 Harmonic voltage and current Analysis window Analysis order Measurement accuracy Measurement method rectangular 1st to 50th order Voltage / Current: 1st to 20th orders: 0.5 % reading 0.2 % full scale, 21st to 50th orders: 1 % reading 0.3 % full scale (current sensor accuracy must be included for current and power) IEC 61000-4-7 Inter-harmonic voltage and current (intermediate harmonics) Analysis window Analysis orders Measurement method rectangular 1.5 to 49.5th order IEC 61000-4-7 Voltage flicker Measurement method 7 Fluke Corporation as per EN 61000-4-15:2003: 10 min (Pst), 2 h (Plt) Fluke 1750 Three-Phase Power Recorder External Interface Specifications LAN interface Connector Speed and type Communications protocol RJ-45 10/100 Base-T, auto MDIX TCP/IP over Ethernet Wireless controller interface Connection Speed Communications protocol wireless (2.4 GHz radio) up to 700 kbit/second Bluetooth SPP Environmental and safety specifications Operating environment Storage temperature and humidity Operating temperature and humidity Indoors or in covered area outdoors, up to 2000 m altitude (for compliance to IEC61010 standard) -20 C to 50 C, 80 % RH max, non-condensing 0 C to 40 C, 80 % RH max, non-condensing Maximum rated working voltage Voltage terminals Voltage durability Enclosure protection 1100 V rms 5550 V rms ac for 1 minute, between voltage input terminals, voltage input terminals and current probes, and voltage input terminals and case (50/60 Hz, 1 mA sense current) IP30 (per EN 60529) Standards conformance EN 61326-1:1997+A1:1998 Class A EN 61000-3-2:1995+A1:1998+A2:1998 EN 61000-3-3:1995 EN 61010-1 2nd Edition; 2000 Voltage input unit: Contamination Level 2, Overvoltage Category 1000 V CAT III, 600 V CAT IV (anticipated overvoltage: 8000 V) EMC Safety Ordering information Fluke 1750 Three-Phase Power Recorder Includes: * 1750 acquisition unit * PDA wireless "front panel interface" and charger power plug adapters * 4 - 400 A current probes (3140R) * 5 test leads and clips * SD memory card * Fluke Power View and Fluke Power Analyze software * Power cord with international plug set * Ethernet cable * Color localization set * Printed Getting Started manual * Product CD with software and users manual PDF * Soft carrying case Fluke 1750/B Three-Phase Basic Power Recorder Includes items above with the exception of the 4 - 400 A current probes (3140R) Fluke. Keeping your world up and running.(R) Fluke offers a full suite of power quality test tools to locate, predict, prevent and troubleshoot power problems. * Handheld troubleshooters for instant analysis * Ready-to-use power loggers * Comprehensive power quality recorders * Power calibrators and standards backed by Fluke metrology expertise The Fluke power quality set of products offers the highest level of performance and maintains the Fluke promise of rugged and reliable test tools. 8 Fluke Corporation Fluke Corporation PO Box 9090, Everett, WA 98206 U.S.A. Fluke Europe B.V. PO Box 1186, 5602 BD Eindhoven, The Netherlands For more information call: In the U.S.A. (800) 443-5853 or Fax (425) 446-5116 In Europe/M-East/Africa +31 (0) 40 2675 200 or Fax +31 (0) 40 2675 222 In Canada (800)-36-FLUKE or Fax (905) 890-6866 From other countries +1 (425) 446-5500 or Fax +1 (425) 446-5116 Web access: http://www.fluke.com (c)2006-2009 Fluke Corporation. Windows(R) is a registered trademark of Microsoft Corporation. Specifications subject to change without notice. Printed in U.S.A. 10/2009 2428201F D-EN-N Modification of this document is not permitted without written permission from Fluke Corporation. Fluke 1750 Three-Phase Power Recorder Pub-ID 11578-eng Mouser Electronics Authorized Distributor Click to View Pricing, Inventory, Delivery & Lifecycle Information: Fluke: FLUKE-1750 FLUKE-1750/CASE FLUKE-1750/SITE-L FLUKE-1750/B FLUKE-1750/MC2GB