CONTROLS CONTROLS EI SERIES CURRENT CONTROL RELAY UL cUL listed 3 Product Types for Measurement Accuracy Under or Over Current - Selectable Space Saving 22.5mm Wide DIN-Rail / Surface Mount Three product types; EIL (2 to 500 mA), EIH (.1 to 10A) and EIT (10 to 100A with current transformers) provide selectable over or under current control. AC/DC control without memory. When the value of the controlled current, either AC or DC, reaches the threshold displayed on the front face, the output relay change state at the end of time delay T1. It returns to the initial state instantly when the current drops below the hysteresis threshold, or when the power supply is disconnected. AC/DC control with memory. When the value of the controlled current reaches the displayed threshold, the output relay changes status at the end of time period T1 and remains locked in this position. To reset the memory function the auxiliary supply must be disconnected. Over-current function (UPPER). The power-on time delay T2 prevents current peaks due to motor starting. The delay on upward crossing of threshold T1 provides immunity to transients and other interference, thereby preventing spurious triggering of the output relay. Under-current function (UNDER). The power-on delay T2 prevents the occurrence of current troughs. The delay on downward crossing of threshold T1 provides immunity to random dips, thereby preventing spurious triggering of the output relay. AC/DC CONTROL WITH MEMORY Un Unit power-up Controlled current Hysteresis Threshold I Hysteresis T2 T1 T2 T1 UPPER function T2 T1 T2 T1 Hysteresis Threshold I UNDER function Hysteresis Controlled current memory AC/DC CONTROL WITHOUT MEMORY Un Unit power-up Note: In underload function, the absolute value of the hysteresis cannot be greater than the measurement range maximum. Controlled current Threshold I Hysteresis Input resistance EIH E2-M E3 M E1-M 2 to 10 to 50 to .01 to 20 mA 100 mA 500 mA 1 A .5 to 5A 1 to 10 A 10 to 100 A 0.02 0.01 20 1 E3 M EIT E1-M 5 E2-M 0.2 0.1 T2 Controlled current Hysteresis Threshold I Hysteresis T2 T1 T1 T2 UNDER function WIRING DIAGRAM EIL EIH ~ ~ 11 A1 11 M WIRING DIAGRAM EIT 11 26 852 304 transformer A1 11 M E1 E2 E3 E1 E2 E3 12 14 ~ 12 14 14 12 A2 14 12 A2 ~ A1&A2 power supply A1&A2 power supply DIMENSIONS: inches (mm) .17 (4.2) 3.10 (78.5) Measurement range EIL E1-M T1 T1 UPPER function 2.25 (57) Input power . . . . . . . . . . . . . . . . . . . . . . . . . . . 24 VDC, 24, 110 to 230 VAC 15%, 50/60 Hz Power Consumption . . . . . . . . . . . . . . . . . . . . 3 VA Hysteresis Selection . . . . . . . . . . . . . . . . . . . . 5 to 50% of Displayed Threshold Threshold Value . . . . . . . . . . . . . . . . . . . . . . . 10 to 100% of Measurement Range Setting Accuracy-Threshold. . . . . . . . . . . . . . 10% Repeat Accuracy. . . . . . . . . . . . . . . . . . . . . . . 0.1% with constant parameters Voltage drift. . . . . . . . . . . . . . . . . . . . . . . . . . . 0.1% (10% of input voltage) Temperature drift . . . . . . . . . . . . . . . . . . . . . . 0.02% Power up delay T2. . . . . . . . . . . . . . . . . . . . . . 1 s to 20 s, 30% Delay on threshold overrun T1 . . . . . . . . . . . . 0.1 s to 3 s, 20% Output relay . . . . . . . . . . . . . . . . . . . . . . . . . . SPDT Relay Contact Material . . . . . . . . . . . . . . . . . . . . . . . AgCdO Maximum Loading . . . . . . . . . . . . . . . . . . . . . 8A AC resist Operating temperature . . . . . . . . . . . . . . . . . . to 140F, -20C to 60C Storage temperature . . . . . . . . . . . . . . . . . . . . -30C to 70C Weight . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . (140g) Types Inputs Sensitivity Hysteresis T2 .14 (3.5) 3.53 (89.7) SPECIFICATIONS: 3.92 (99.3) * * * * Note: 24VDC input power version. The input voltage and the measured current must be from separate sources. The "negative" poles of the auxiliary power supply and the measurement circuit are connected inside the unit Type EIL Measurement range 2 to 500 mA Supply voltage 24 VDC 84 871 020 24 VAC 84 871 021 48 VAC 84 871 022 120 VAC 84 871 023 230 VAC 84 871 024 Current transformer 2.84 (72) 3.94 (100) EIH EIT 10 to 100 A 0.1 to 10 A with current transformer Transformer 84 871 030 84 871 040 ref. 26 852 304 84 871 031 84 871 041 84 871 032 84 871 042 84 871 033 84 871 043 84 871 034 84 871 044 26 852 304 Products and specifications subject to change without notice. .20 (5) (22.5) .89 2 tag connectors O (6.35) .51 O(.13) 1.50 (39) PART NUMBER FOR ORDERING (38) 1.50 (20) .78 Consult factory for application assistance. 204 Airline Drive, Suite 300, Coppell, Texas 75019 / Tel: (800) 677-5311 / FAX: (800) 677-3865 / www.crouzet-usa.com 5-20 Mouser Electronics Authorized Distributor Click to View Pricing, Inventory, Delivery & Lifecycle Information: Crouzet: 84871041 84871044 84871021 84871023 84871043 84871020 84871030 84871040 84871022 84871031 84871034