SINGLE-PHASE GLASS PASSIVATED SILICON BRIDGE RECTIFIER RBU1501M THRU RBU1507M VOLTAGE RANGE 50 to 1000 Volts CURRENT 15.0 Amperes FEATURES * * * * * Low leakage Low forward voltage Silver-plated copper leads Surge overload rating: 250 amperes peak Mounting position: Any RBU MECHANICAL DATA * Epoxy: Device has UL flammability classification 94V-O Please See Page 3 for Dimension MAXIMUM RATINGS AND ELECTRICAL CHARACTERISTICS Ratings at 25 o C ambient temperature unless otherwise specified. resistive or inductive load. Dimensions in inches and (millimeters) MAXIMUM RATINGS (@ TA=25 OC unless otherwise noted) RATINGS SYMBOL RBU1501M RBU1502M RBU1503M RBU1504M RBU1505M RBU1506M RBU1507M UNITS Maximum Recurrent Peak Reverse Voltage VRRM 50 100 200 400 600 800 1000 Volts Maximum RMS Voltage VRMS 35 70 140 280 420 560 700 Volts VDC 50 100 200 400 600 800 1000 Volts Maximum DC Blocking Voltage Maximum Average Forward Rectified Current at T C = *100 o C (Note 4) Peak Forward Surge Current 8.3 ms single half sine-wave superimposed on rated load (JEDEC method) IO 15.0 Amps I FSM 250 Amps I t 259.2 A 2 /Sec T J, T STG -55 to + 150 2 Typical Current Squarad Time Operating and Storage Temperature Range 0 C ELECTRICAL CHARACTERISTICS (@TA=25 C unless otherwise noted) O CHARACTERISTICS Maximum Instantaneous Forward Voltage at 7.5A DC Maximum DC Reverse Current at Rated DC Blocking Voltage @T A = 25 o C @T A = 100 o C SYMBOL RBU1501M RBU1502M RBU1503M RBU1504M RBU1505M RBU1506M RBU1507M VF IR NOTES : 1. "Fully ROHS compliant", "100% Sn plating (Pb-free)". 2. "*" Heat Sink Temperature. 3. Available in Halogen-free epoxy by adding suffix -HF after the part nbr. 1.1 UNITS Volts 5.0 100 uAmps 2010-05 REV: B 30 20 60 10 50 POWER DISSIPATION, ( W) INSTANTANEOUS FORWARD CURRENT, (A) RATING AND CHARACTERISTICS CURVES ( RBU1501M THRU RBU1507M ) TC= 150 OC (TYP) 5 TC= 25 OC (TYP) 2 1 0.5 0.2 0 Pulse test per one diode 0.2 0.4 0.6 0.8 1 1.2 1.4 40 30 20 10 0 1.6 sine wave TJ = 150 OC 0 INSTANTANEOUS FORWARD VOLTAGE, (V) 0 8.3ms 8.3ms 200 1 cycle non-repetitive Tj=25 100 0 0 1 2 5 10 20 50 16 20 24 3 P.C.B soldering land 5mmf sine wave R-load free in air 2 1 0 100 on glass-epoxi substrate 0 40 80 120 160 CASE TEMPERATURE, (OC) FIG.4 TYPICAL FORWARD CURRENT DERATING CURVE FIG.3 SURGE FORWARD CURRENT CAPABILITY 18 1.2 17 THERMAL RESISTANCE (OC/W) AVERAGE FORWARD CURRENT, (A) 12 4 NUMBER OF CYCLE 16 14 12 heatsink Tc Tc 10 8 6 sine wave R-load on heatsink 4 2 0 10 8 FIG.2 POWER DISSIPATION AVERAGE FORWARD CURRENT, (A) sine wave IFSM PEAK FORWARD SURGE CURRENT, (A) FIG.1 TYPICAL INSTANTANEOUS FORWARD CHARACTERITICS 300 4 AVERAGE RECTIFIED FORWARD CURRENT, (A) 30 50 70 90 110 130 HEAT SINK TEMPERATURE, (OC) 150 FIG.5 TYPICAL FORWARD CURRENT DERATING CURVE 170 with thermal compound 1.0 0.8 0.6 0.4 0.2 0 2 3 4 5 6 7 MOUNTING TORQUE (kg.cm) FIG.6 CONTACT THERMAL RESISTANCE fcf 8 .140 (3.56) .130 (3.30) .160 (4.1) .140 (3.5) .075 (1.9)R .512 (13.0) .740 (18.8) .720 (18.3) .366 (9.3) .343 (8.7) .085 (2.16) .065 (1.65) .880 (22.3) .860 (21.8) .080 (2.03) .060 (1.52) .310(7.9) .290(7.4) Dimensions in inches and (millimeters) .085 (2.16) .075 (1.90) .210 (5.33) .190 (4.83) .080 (2.03) .065 (1.65) .050 (1.27) .040 (1.02) .710 (18.0) .690 (17.5) .100 (2.54) .085 (2.16) .022 (0.56) .018 (0.46) Marking Description Rectron Logo RBU150XM Part No. Voltage-code UL Logo Year - code (Y:Last digit of year& A:2010,B:2011......) VYWW Week - code: (WW:01~52) 1-------50V 5-------600V 2-------100V 6-------800V 3-------200V 4-------400V 7-------1000V PACKAGING OF DIODE AND BRIDGE RECTIFIERS BULK PACK EA PER BOX INNER BOX SIZE CARTON SIZE PACKING CODE RBU -B 450 240*239*35 502*251*126 2,700 13.00 PACKAGE PACKING CODE EA PER BOX INNER BOX SIZE CARTON SIZE EA PER CARTON WEIGHT(Kg) RBU -C 1,000 490*135*110 510*293*131 2,000 13.62 (mm) (mm) EA PER CARTON GROSS WEIGHT(Kg) PACKAGE TUBE PACK (mm) (mm) DISCLAIMER NOTICE Rectron Inc reserves the right to make changes without notice to any product specification herein, to make corrections, modifications, enhancements or other changes. Rectron Inc or anyone on its behalf assumes no responsibility or liability for any errors or inaccuracies. Data sheet specifications and its information contained are intended to provide a product description only. "Typical" parameters which may be included on RECTRON data sheets and/ or specifications can and do vary in different applications and actual performance may vary over time. Rectron Inc does not assume any liability arising out of the application or use of any product or circuit. Rectron products are not designed, intended or authorized for use in medical, life-saving implant or other applications intended for life-sustaining or other related applications where a failure or malfunction of component or circuitry may directly or indirectly cause injury or threaten a life without expressed written approval of Rectron Inc. Customers using or selling Rectron components for use in such applications do so at their own risk and shall agree to fully indemnify Rectron Inc and its subsidiaries harmless against all claims, damages and expenditures.