2007-04-19
1
BAL99...
Silicon Switching Diode
For high-speed switching applications
Pb-free (RoHS compliant) package1)
Qualified according AEC Q101
BAL99
!
Type Package Configuration Marking
BAL99 SOT23 single JFs
Maximum Ratings at TA = 25°C, unless otherwise specified
Parameter Symbol Value Unit
Diode reverse voltage VR80 V
Peak reverse voltage- VRM 85
Forward current IF250 mA
Peak forward current IFM -
Surge forward current, t = 1 µs IFS 4.5 A
Total power dissipation
TS 54°C Ptot 370 mW
Junction temperature Tj150 °C
Storage temperature Tstg -65 ... 150
Thermal Resistance
Parameter Symbol Value Unit
Junction - soldering point2) RthJS 260 K/W
1Pb-containing package may be available upon special request
2For calculation of RthJA please refer to Application Note Thermal Resistance
2007-04-19
2
BAL99...
Electrical Characteristics at TA = 25°C, unless otherwise specified
Parameter Symbol Values Unit
min. typ. max.
DC Characteristics
Breakdown voltage
I(BR) = 100 µA V(BR) 85 - - V
Reverse current
VR = 70 V
VR = 25 V, TA = 150 °C
VR = 70 V, TA = 150 °C
IR
-
-
-
-
-
-
1
30
50
µA
Forward voltage
IF = 1 mA
IF = 10 mA
IF = 50 mA
IF = 150 mA
VF
-
-
-
-
-
-
-
-
715
855
1000
1250
mV
AC Characteristics
Diode capacitance
VR = 0 V, f = 1 MHz CT- - 1.5 pF
Reverse recovery time
IF = 10 mA, IR = 10 mA, measured at IR = 1mA ,
RL = 100
trr - - 4 ns
Test circuit for reverse recovery time
EHN00014
Oscillograph
Ι
F
D.U.T.
Puls generator: tp = 100ns, D = 0.05,
tr = 0.6ns, Ri = 50
Oscillograph: R = 50, tr = 0.35ns
C 1pf
2007-04-19
3
BAL99...
Reverse current IR = ƒ (TA)
VR = Parameter
10
10
0 50 100 150
BAL 99 EHB00007
nA
T
A
Ι
R
˚C
10
2
1
5
5
5
25V
70V
max.
= 70 V
R
V
typ.
3
10
4
10
5
Forward Voltage VF = ƒ (TA)
IF = Parameter
0
0.5
1.0
0 50 100 150
BAL 99 EHB00010
V
T
A
V
F
˚C
Ι
F
= 100 mA
10 mA
1 mA
0.1 mA
Forward current IF = ƒ (VF)
0
0
EHB00008BAL 99
Ι
0.5 1.0 V 1.5
50
100
mA
150
F
F
V
maxtyp
Peak forward current IFM = ƒ (tp)
TA = 25°C
10
EHB00009
Ι
FM
t
-2 -6
10
D= 0.005
0.01
0.02
T
D=T
BAL 99
10-5 10-4 10-3 10-2 10-1 100
s
-1
10
0
10
1
10
2
10
A
tptp
0.05
0.1
0.2
2007-04-19
4
BAL99...
Forward current IF = ƒ (TS)
0 15 30 45 60 75 90 105 120 °C 150
TS
0
50
100
150
200
mA
300
IF
2007-04-19
5
BAL99...
Package SOT23
Package Outline
Foot Print
Marking Layout (Example)
Standard Packing
Reel ø180 mm = 3.000 Pieces/Reel
Reel ø330 mm = 10.000 Pieces/Reel
EH
s
BCW66
Type code
Pin 1
0.8
0.9 0.91.3
0.8 1.2
0.25 MBC
1.9
-0.05
+0.1
0.4
±0.1
2.9
0.95
C
B
0...8˚
0.2 A
0.1 MAX.
10˚ MAX.
0.08...0.15
1.3
±0.1
10˚ MAX.
M
2.4
±0.15
±0.1
1
A
0.15 MIN.
1)
1) Lead width can be 0.6 max. in dambar area
12
3
3.15
4
2.65
2.13
0.9
8
0.2
1.15
Pin 1
Manufacturer
2005, June
Date code (YM)
2007-04-19
6
BAL99...
Edition 2006-02-01
Published by
Infineon Technologies AG
81726 München, Germany
© Infineon Technologies AG 2007.
All Rights Reserved.
Attention please!
The information given in this dokument shall in no event be regarded as a guarantee
of conditions or characteristics (“Beschaffenheitsgarantie”). With respect to any
examples or hints given herein, any typical values stated herein and/or any information
regarding the application of the device, Infineon Technologies hereby disclaims any
and all warranties and liabilities of any kind, including without limitation warranties of
non-infringement of intellectual property rights of any third party.
Information
For further information on technology, delivery terms and conditions and prices
please contact your nearest Infineon Technologies Office (www.infineon.com).
Warnings
Due to technical requirements components may contain dangerous substances.
For information on the types in question please contact your nearest
Infineon Technologies Office.
Infineon Technologies Components may only be used in life-support devices or
systems with the express written approval of Infineon Technologies, if a failure of
such components can reasonably be expected to cause the failure of that
life-support device or system, or to affect the safety or effectiveness of that
device or system.
Life support devices or systems are intended to be implanted in the human body,
or to support and/or maintain and sustain and/or protect human life. If they fail,
it is reasonable to assume that the health of the user or other persons
may be endangered.