Features
RoHS lead-solder-exempt compliant
Wide Range Input for 110/220 VAC Applications
Meets EN55022, Conducted Class B Limits
Compact Footprint: 6.00" x 3.27" x 1.60"
(152.4mm x 83.1mm x 40.6mm)
Greater than 225,000 Hours MTBF
Metric and SAE Mounting Inserts
Single-Output Model Selection
MODEL OUTPUT ADJUSTMENT MAXIMUM OUTPUT PEAK OUTPUT LINE LOAD RIPPLE & NOISE INITIAL SETTING
VOLTAGE RANGE CURRENT CURRENT (NOTE 3) REGULATION REGULATION %p-p (NOTE 1) ACCURACY
MAP40-1005 5V 4.7V to 5.50V 8A 11A 0.2% ±1.5% 1% 5.0V to 5.2V
MAP55-1012 12V/15V 11.4V to 15.75V 5.0/4.0A (Note 2) 5.8/4.7A (Note 2) 0.2% ±1% 1% 12.0V to 12.2V
MAP55-1024 24V/28V 23.5V to 28.5V 2.5/2.2A (Note 2) 2.9/2.5A (Note 2) 0.2% 1% 1% 23.8V to 24.2V
NOTES: 1) Maximum peak to peak noise expressed as a percentage of output voltage, 20 MHz bandwidth.
2) MAP55-1012 output currents are expressed as 12V/15V operation. MAP55-1024 output currents are expressed as 24V/28V operation.
3) Peak load for 60 seconds or less are acceptable, 10% duty cycle, maximum.
Multiple-Output Model Selection
55W Continuous Output Power
MODEL OUTPUT ADJUSTMENT OUTPUT PEAK OUTPUT LINE LOAD RIPPLE & NOISE INITIAL SETTING
VOLTAGE RANGE CURRENT CURRENT (NOTE 1) REGULATION REGULATION %p-p (NOTE 2) ACCURACY
+5V 4.7V to 5.6V 6A 8A 0.2% 2% 1% 5.0V to 5.2V
MAP55-4000 +12V Fixed 3A 5A 0.2% 2% 1% 11.6V to 12.4V
-5V Fixed 0.5A 1A (Note 3) 0.5% 2% 1% -4.8V to -5.2V
-12V Fixed 0.5A 1A (Note 3) 0.5% 2% 1% -11.6V to -12.4V
+5V 4.7V to 5.6V 6A 8A 0.2% 2% 1% 5.0V to 5.2V
MAP55-4001 +24V Fixed 1.5A 2.5A 0.2% 2% 1% 23.0V to 24.9V
-12V Fixed 0.5A 1A (Note 3) 0.5% 2% 1% -11.6V to -12.4V
+12V Fixed 0.5A 1A (Note 3) 0.5% 2% 1% 11.6V to 12.4V
+5V 4.7V to 5.6V 6A 8A 0.2% 2% 1% 5.0V to 5.2V
MAP55-4002 +12V Fixed 3A 5A 0.2% 2% 1% 11.6V to 12.4V
-12V Fixed 0.5A 1A (Note 3) 0.5% 2% 1% -11.6V to -12.4V
+12V Fixed 0.5A 1A (Note 3) 0.5% 2% 1% 11.6V to 12.4V
+5V 4.7V to 5.6V 6A 8A 0.2% 2% 1% 5.0V to 5.2V
MAP55-4003 +15V Fixed 2.5A 3.5A 0.2% 2% 1% 14.6V to 15.4V
-5V Fixed 0.5A 1A (Note 3) 0.5% 2% 1% -4.8V to -5.2V
-15V Fixed 0.5A 1A (Note 3) 0.5% 2% 1% -14.4V to -15.6V
+5V 4.7V to 5.6V 6A 8A 0.2% 2% 1% 5.0V to 5.2V
MAP55-4004 +24V Fixed 1.5A 2.5A 0.2% 2% 1% 23.0V to 24.9V
-15V Fixed 0.5A 1A (Note 3) 0.5% 2% 1% -14.5V to -15.5V
+15V Fixed 0.5A 1A (Note 3) 0.5% 2% 1% 14.5V to 15.5V
NOTES: 1) Peak loads up to 65 watts for 60 seconds or less are acceptable, (10% duty cycle max.). Peak power must not exceed 65 watts.
2) Maximum peak to peak noise expressed as a percentage of output voltage, 20 MHz bandwidth.
3) Maximum load on V3 or V4 could be 1 amp continuous if output V4 or V3 is unloaded.
MAP55 AC-DC Series Data Sheet
JUL 14, 2006 revised to AUG 10, 2006 Page 1 of 3 www.power-one.com
Description
Power-One's MAP55 Series of power supplies provides reliable, tightly-regulated DC power for commercial and
industrial systems. Wide-range AC input and full international safety, EMI, and ESD compliance ensure worldwide
acceptance. All units bear the CE Mark.
The MAP55 utilizes a thermally efficient U-channel chassis design, which allows full power operation in convection-
cooled applications. Other mechanical design innovations include metric and SAE mounting inserts on each mounting
surface to provide integration flexibility. Dual-mode connectors provide traditional terminal block connections or popular
single row Molex connector mating.
Single-output models feature wide-range output adjustability to meet a wide variety of st andard and user-specific output
voltage requirements.
MAP55 AC-DC Series Data Sheet
JUL 14, 2006 revised to AUG 10, 2006 Page 2 of 3 www.power-one.com
Input Specifications
PARAMETER CONDITIONS/DESCRIPTION MIN NOM MAX UNITS
Input Voltage - AC Continuous input range. 90 132 VAC
175 264
Input Frequency AC input. 47 63 Hz
Brown Out Protection Lowest AC input voltage that regulation is maintained with full rated loads. 90 VAC
Hold-up Time Nominal AC Input Voltage (115VAC), full rated load. 20 ms
Input Current 90 VAC (55W load). 1.6 ARMS
Input Protection Non-user serviceable internally located AC input line fuse.
Inrush Surge Current Internally limited by thermistor. Vin = 264VAC (one cycle). 25° C. 38 APK
Operating Frequency Switching frequency of power supply (varies with load). 22 180 kHz
Output Specifications
PARAMETER CONDITIONS/DESCRIPTION MIN NOM MAX UNITS
Efficiency Full load, 115VAC. Varies with distribution of loads among outputs. 73 %
Minimum Loads MAP55-1012 0.21
MAP55-1024 0.11 Amps
MAP40-1005 and all multiple output models, main channel only. 0.50
Ripple and Noise Full load, 20MHz bandwidth. See Model Selection Chart.
Output Power Continuous output power, all multiple output models. 55 Watts
Peak output power (60s maximum, 10% duty cycle), all multiple output models. 65 Watts
Overshoot / Undershoot Output voltage overshoot/undershoot at turn-on, V1, V2. 1 %
Regulation Varies by output. Total regulation includes: line changes from 90-132 VAC or 175-264 VAC, See Model Selection Chart.
changes in load starting at 20% load and changing to 100% load.
Transient Response Recovery time, to within 1% of initial set point due to a 50-100% 500 μs
load change, 4% max. deviation. (Main output of multiple output units).
Turn-on Delay Time required for initial output voltage stabilization. 1 4 Sec
Turn-on Rise Time Time required for output voltage to rise from 10% to 90% (Note 1). 7 ms
NOTES: 1) Nominal rise time for MAP55-1024 is 36 msec.
Interface Signals and Internal Protection
PARAMETER CONDITIONS/DESCRIPTION MIN NOM MAX UNITS
Overvoltage Protection MAP40-1005 5.5 6.8
MAP55-1012 17.5 19.7 V
MAP55-1024 32.0 36.0
Main output only of multiple output units. 5.6 6.8
Overload Protection Fully protected against output overload and short circuit. Automatic recovery upon removal of overload condition.
Safety, Regulatory, and EMI Specifications
PARAMETER CONDITIONS/DESCRIPTION MIN NOM MAX UNITS
Agency Approvals UL1950.
CSA 22.2 No. 234/950. Approved.
EN60950 (TUV).
Dielectric Withstand Input to output. 2600 VDC
Voltage
Electromagnetic FCC CFR title 47 Part 15 Sub-Part B - conducted & radiated. B
Interference, EN55022 / CISPR 22 conducted. B Class
Conducted EN55022 / CISPR 22 radiated. A
Insulation Resistance Input to output. 7 MΩ
Leakage Current Per EN60950, 264VAC. 500 µA
NUCLEAR AND MEDICALAPPLICATIONS - Power-One products are not designed, intended for use in, or authorized for use as critical components
in life support systems, equipment used in hazardous environments, or nuclear control systems without the express written consent of the respective
divisional president of Power-One, Inc.
TECHNICAL REVISIONS - The appearance of products, including safety agency certifications pictured on labels, may change depending on the date
manufactured. Specifications are subject to change without notice.
MAP55 AC-DC Series Data Sheet
JUL 14, 2006 revised to AUG 10, 2006 Page 3 of 3 www.power-one.com
Environmental Specifications
PARAMETER CONDITIONS/DESCRIPTION MIN NOM MAX UNITS
Altitude Operating. 10k Feet
Non-operating. 40k
Operating Temperature Derate linearly above 50°C by 2.5% per °C At 100% load: 0 50 °C
to a maximum temperature of 70°C. At 50% load: 0 70 °C
Storage Temperature -40 85 °C
Temperature Coefficient 0°C to 70°C (after 15 minute warm-up). ±0.02 ±0.03 %/°C
Relative Humidity Non-condensing. 5 95 %RH
Shock Operating, peak acceleration. 20 G
Vibration Random vibration, 10 Hz to 2 kHz, 3 axis. 6 GRMS
Options
DESCRIPTION NOTES DIMENSIONS
Cover Add ‘C’ suffix to model number or order part number 412-59584-G separately. 6.00" x 3.27" x 1.85"
For convection cooled applications, derate output power to 45 watts on multiple (152.4mm x 83.1mm x 47.0mm)
output units, 50 watts on MAP55-1012 and MAP55-1024,and 40 watts on MAP40-1005.
OVERALL SIZE: 6.00" x 3.27" x 1.60" (152.4mm x 83.1mm x 40.6mm)
WEIGHT: 1.1 LBS (0.55 kg)
INPUT & OUTPUT CONNECTIONS: 6-32 SCREW WIRE CLAMPS ON 0.312" (7.9mm) CENTERS, 0.045" (1.1mm)
SQUARE PINS ON 0.156" (3.4mm) CENTERS, MATES WITH MOLEX SERIES
2139, 6442, OR 41695
CHASSIS: 0.090" (2.3mm) ALUMINUM ALLOY, WITH CLEAR FINISH