MAP55 AC-DC Series Data Sheet Features Description * RoHS lead-solder-exempt compliant * Wide Range Input for 110/220 VAC Applications * Meets EN55022, Conducted Class B Limits * Compact Footprint: 6.00" x 3.27" x 1.60" (152.4mm x 83.1mm x 40.6mm) * Greater than 225,000 Hours MTBF * Metric and SAE Mounting Inserts Power-One's MAP55 Series of power supplies provides reliable, tightly-regulated DC power for commercial and industrial systems. Wide-range AC input and full international safety, EMI, and ESD compliance ensure worldwide acceptance. All units bear the CE Mark. The MAP55 utilizes a thermally efficient U-channel chassis design, which allows full power operation in convectioncooled applications. Other mechanical design innovations include metric and SAE mounting inserts on each mounting surface to provide integration flexibility. Dual-mode connectors provide traditional terminal block connections or popular single row Molex connector mating. Single-output models feature wide-range output adjustability to meet a wide variety of standard and user-specific output voltage requirements. Single-Output Model Selection OUTPUT VOLTAGE MODEL MAP40-1005 5V MAP55-1012 12V/15V MAP55-1024 24V/28V NOTES: ADJUSTMENT RANGE MAXIMUM OUTPUT CURRENT PEAK OUTPUT CURRENT (NOTE 3) LINE REGULATION LOAD REGULATION RIPPLE & NOISE %p-p (NOTE 1) INITIAL SETTING ACCURACY 4.7V to 5.50V 11.4V to 15.75V 23.5V to 28.5V 8A 5.0/4.0A (Note 2) 2.5/2.2A (Note 2) 11A 5.8/4.7A (Note 2) 2.9/2.5A (Note 2) 0.2% 0.2% 0.2% 1.5% 1% 1% 1% 1% 1% 5.0V to 5.2V 12.0V to 12.2V 23.8V to 24.2V 1) Maximum peak to peak noise expressed as a percentage of output voltage, 20 MHz bandwidth. 2) MAP55-1012 output currents are expressed as 12V/15V operation. MAP55-1024 output currents are expressed as 24V/28V operation. 3) Peak load for 60 seconds or less are acceptable, 10% duty cycle, maximum. Multiple-Output Model Selection - 55W Continuous Output Power MODEL MAP55-4000 MAP55-4001 MAP55-4002 MAP55-4003 MAP55-4004 NOTES: OUTPUT VOLTAGE ADJUSTMENT RANGE OUTPUT CURRENT PEAK OUTPUT CURRENT (NOTE 1) LINE REGULATION LOAD REGULATION RIPPLE & NOISE %p-p (NOTE 2) INITIAL SETTING ACCURACY +5V +12V -5V -12V +5V +24V -12V +12V +5V +12V -12V +12V +5V +15V -5V -15V +5V +24V -15V +15V 4.7V to 5.6V Fixed Fixed Fixed 4.7V to 5.6V Fixed Fixed Fixed 4.7V to 5.6V Fixed Fixed Fixed 4.7V to 5.6V Fixed Fixed Fixed 4.7V to 5.6V Fixed Fixed Fixed 6A 3A 0.5A 0.5A 6A 1.5A 0.5A 0.5A 6A 3A 0.5A 0.5A 6A 2.5A 0.5A 0.5A 6A 1.5A 0.5A 0.5A 8A 5A 1A (Note 3) 1A (Note 3) 8A 2.5A 1A (Note 3) 1A (Note 3) 8A 5A 1A (Note 3) 1A (Note 3) 8A 3.5A 1A (Note 3) 1A (Note 3) 8A 2.5A 1A (Note 3) 1A (Note 3) 0.2% 0.2% 0.5% 0.5% 0.2% 0.2% 0.5% 0.5% 0.2% 0.2% 0.5% 0.5% 0.2% 0.2% 0.5% 0.5% 0.2% 0.2% 0.5% 0.5% 2% 2% 2% 2% 2% 2% 2% 2% 2% 2% 2% 2% 2% 2% 2% 2% 2% 2% 2% 2% 1% 1% 1% 1% 1% 1% 1% 1% 1% 1% 1% 1% 1% 1% 1% 1% 1% 1% 1% 1% 5.0V to 5.2V 11.6V to 12.4V -4.8V to -5.2V -11.6V to -12.4V 5.0V to 5.2V 23.0V to 24.9V -11.6V to -12.4V 11.6V to 12.4V 5.0V to 5.2V 11.6V to 12.4V -11.6V to -12.4V 11.6V to 12.4V 5.0V to 5.2V 14.6V to 15.4V -4.8V to -5.2V -14.4V to -15.6V 5.0V to 5.2V 23.0V to 24.9V -14.5V to -15.5V 14.5V to 15.5V 1) Peak loads up to 65 watts for 60 seconds or less are acceptable, (10% duty cycle max.). Peak power must not exceed 65 watts. 2) Maximum peak to peak noise expressed as a percentage of output voltage, 20 MHz bandwidth. 3) Maximum load on V3 or V4 could be 1 amp continuous if output V4 or V3 is unloaded. JUL 14, 2006 revised to AUG 10, 2006 Page 1 of 3 www.power-one.com MAP55 AC-DC Series Data Sheet Input Specifications PARAMETER CONDITIONS/DESCRIPTION MIN Input Voltage - AC Continuous input range. Input Frequency Brown Out Protection Hold-up Time Input Current Input Protection Inrush Surge Current AC input. Lowest AC input voltage that regulation is maintained with full rated loads. Nominal AC Input Voltage (115VAC), full rated load. 90 VAC (55W load). Non-user serviceable internally located AC input line fuse. Internally limited by thermistor. Vin = 264VAC (one cycle). 25 C. 90 175 47 90 20 Operating Frequency Switching frequency of power supply (varies with load). 22 PARAMETER CONDITIONS/DESCRIPTION MIN Efficiency Minimum Loads Full load, 115VAC. Varies with distribution of loads among outputs. 73 MAP55-1012 0.21 MAP55-1024 0.11 MAP40-1005 and all multiple output models, main channel only. 0.50 Full load, 20MHz bandwidth. Continuous output power, all multiple output models. Peak output power (60s maximum, 10% duty cycle), all multiple output models. Output voltage overshoot/undershoot at turn-on, V1, V2. Varies by output. Total regulation includes: line changes from 90-132 VAC or 175-264 VAC, changes in load starting at 20% load and changing to 100% load. Recovery time, to within 1% of initial set point due to a 50-100% load change, 4% max. deviation. (Main output of multiple output units). Time required for initial output voltage stabilization. 1 Time required for output voltage to rise from 10% to 90% (Note 1). NOM MAX UNITS 132 264 63 VAC 1.6 Hz VAC ms ARMS 38 APK 180 kHz MAX UNITS Output Specifications Ripple and Noise Output Power Overshoot / Undershoot Regulation Transient Response Turn-on Delay Turn-on Rise Time NOTES: NOM % Amps See Model Selection Chart. 55 Watts 65 Watts 1 % See Model Selection Chart. 500 s 4 Sec ms MAX UNITS 7 1) Nominal rise time for MAP55-1024 is 36 msec. Interface Signals and Internal Protection PARAMETER CONDITIONS/DESCRIPTION Overvoltage Protection MAP40-1005 5.5 6.8 MAP55-1012 17.5 19.7 MAP55-1024 32.0 36.0 Main output only of multiple output units. 5.6 6.8 Fully protected against output overload and short circuit. Automatic recovery upon removal of overload condition. Overload Protection MIN NOM V Safety, Regulatory, and EMI Specifications PARAMETER CONDITIONS/DESCRIPTION Agency Approvals UL1950. CSA 22.2 No. 234/950. EN60950 (TUV). Input to output. Dielectric Withstand Voltage Electromagnetic Interference, Conducted Insulation Resistance Leakage Current MIN NOM MAX UNITS Approved. 2600 FCC CFR title 47 Part 15 Sub-Part B - conducted & radiated. EN55022 / CISPR 22 conducted. EN55022 / CISPR 22 radiated. Input to output. Per EN60950, 264VAC. VDC B B A 7 Class 500 M A NUCLEAR AND MEDICAL APPLICATIONS - Power-One products are not designed, intended for use in, or authorized for use as critical components in life support systems, equipment used in hazardous environments, or nuclear control systems without the express written consent of the respective divisional president of Power-One, Inc. TECHNICAL REVISIONS - The appearance of products, including safety agency certifications pictured on labels, may change depending on the date manufactured. Specifications are subject to change without notice. JUL 14, 2006 revised to AUG 10, 2006 Page 2 of 3 www.power-one.com MAP55 AC-DC Series Data Sheet Environmental Specifications PARAMETER CONDITIONS/DESCRIPTION Altitude Operating. Non-operating. Derate linearly above 50C by 2.5% per C to a maximum temperature of 70C. Operating Temperature Storage Temperature Temperature Coefficient Relative Humidity Shock Vibration MIN At 100% load: At 50% load: NOM 0 0 -40 0C to 70C (after 15 minute warm-up). Non-condensing. Operating, peak acceleration. Random vibration, 10 Hz to 2 kHz, 3 axis. 0.02 5 MAX UNITS 10k 40k 50 70 85 0.03 95 20 6 Feet C C C %/C %RH G GRMS Options DESCRIPTION NOTES Cover Add `C' suffix to model number or order part number 412-59584-G separately. For convection cooled applications, derate output power to 45 watts on multiple output units, 50 watts on MAP55-1012 and MAP55-1024,and 40 watts on MAP40-1005. DIMENSIONS 6.00" x 3.27" x 1.85" (152.4mm x 83.1mm x 47.0mm) OVERALL SIZE: 6.00" x 3.27" x 1.60" (152.4mm x 83.1mm x 40.6mm) WEIGHT: 1.1 LBS (0.55 kg) INPUT & OUTPUT CONNECTIONS: CHASSIS: 6-32 SCREW WIRE CLAMPS ON 0.312" (7.9mm) CENTERS, 0.045" (1.1mm) SQUARE PINS ON 0.156" (3.4mm) CENTERS, MATES WITH MOLEX SERIES 2139, 6442, OR 41695 0.090" (2.3mm) ALUMINUM ALLOY, WITH CLEAR FINISH JUL 14, 2006 revised to AUG 10, 2006 Page 3 of 3 www.power-one.com