Low Cost Axial Vactrols VTL5C9, 5C10 PACKAGE DIMENSIONS INCH (MM) PLASTIC POTTING CONTOUR NOT CONTROLLED DESCRIPTION VTL5C9 has a 112 db dynamic range, fast response time, high dark resistance, but with a more shallow slope and lower "on" resistance at low (1 mA) drive currents than the VTL5C1. VTL510 offers a low "on" resistance at low drive currents, a fast response time, and has a smaller temperature coefficient than the VTL5C9. ABSOLUTE MAXIMUM RATINGS @ 25C LED Forward Voltage Drop @ 20 mA: Maximum Temperatures Storage and Operating: Cell Power: Derate above 30C: LED Current: Derate above 30C: -40C to 75C 175 mW 3.9 mW/C 40 mA 1 0.9 mA/C LED Reverse Breakdown Voltage: 3.0 V 2.8V (2.2V Typ.) Min. Isolation Voltage @ 70% Rel. Humidity: 2500 VRMS Output Cell Capacitance: 5.0 pF Cell Voltage: 100V (VTL5C9), 50V (VTL5C10) 0.5 pF Input - Output Coupling Capacitance: ELECTRO-OPTICAL CHARCTERISTICS @ 25C ON Resistance 2 OFF 3 Resistance @ 10 sec. (Min.) Slope (Typ.) Dynamic Range (Typ.) @ 0.5 mA -----------------------R@ 5 mA R DARK -----------------------R@ 20 mA Part Number Material Type Input current Dark Adapted (Typ.) VTL5C9 1 2 mA 630 50 M 7.3 VTL5C10 4 2 mA 400 400 K 3.8 Response Time 4 Turn-on to 63% Final RON (Typ.) Turn-off (Decay) to 100 k (Max.) 112 db 4.0 ms 50 ms 75 db 1.0 ms 1.5 sec Refer to Specification Notes, page 41. PerkinElmer Optoelectronics, 10900 Page Ave., St. Louis, MO 63132 USA Phone: 314-423-4900 Fax: 314-423-3956 Web: www.perkinelmer.com/opto 55 Typical Performance Curves Output Resistance vs. Input Current VTL5C9 Response Time VTL5C9 Output Resistance vs. Input Current VTL5C10 Response Time VTL5C10 Input Characteristics Notes: 1. At 1.0 mA and below, units may have substantially higher resistance than shown in the typical curves. Consult factory if closely controlled characteristics are required at low input currents. 2. Output resistance vs input current transfer curves are given for the following light adapt conditions: (1) (2) (3) (4) 3. PerkinElmer Optoelectronics, 10900 Page Ave., St. Louis, MO 63132 USA 25C -- 24 hours @ no input 25C -- 24 hours @ 40 mA input +50C -- 24 hours @ 40 mA input -20C -- 24 hours @ 40 mA input Response time characteristics are based upon test following adapt condition (2) above. Phone: 314-423-4900 Fax: 314-423-3956 Web: www.perkinelmer.com/opto 56