TERMINAL FUNCTION ROCKER BODY PRINT, COLOUR, ETC
H8800 V A - - -
tel: +44 (0)20 8979 3232 • Arcolectric • email: info@arcoswitch.co.uk
8
8800/8800
V
Curved
Switches are ON when pressed over terminal 1
8800 Thinline Rocker Switches 10A 250Vac
ROCKERFUNCTION
ON - OFF
Single pole
TERMINAL
8800
ON - OFF
Twin (Single pole)
H
4.8 x 0.8
T
3.5 x 0.8
Solder
10(6)A 250Vac T100
6(2)A 250Vac T100 5E4 (50,000 Operations)
Inrush 50A to EN60065:1998
UL CSA 15A 250Vac (Twin unit is 10A 250Vac)
UL CSA 125Vac 1/2hp
UL 100˚C, file E45221, CSA file LR10990
10A 28Vdc
RoHS compliant
3mm contact gap.
Technical data on pages 4 & 5.
In house test
9.7
2.6
8.8
1.5
1
1a
Switches are ON when pressed over terminals 1 or 3
3
4
1
2
Ultra thin rocker switch
Ratings up to 15A,
250Vac
Single and twin gang
Bezel sizes:
Single 21 x 9.5
Twin 21 x 15.5
RoHS
tel: +44 (0)20 8979 3232 • Arcolectric • email: info@arcoswitch.co.uk
9
8800V/8800VA (H terminals shown)
Finish
Matt finish only.
Colour
Call factory for custom colours.
A full range is available for large orders.
Legend printing
Select from the examples or call the factory
for custom legends.
Examples of printing
CL132 CL133
H8800VA ---
T8800VA ---
H8800V/H8800VA
T8800V/T8800VA
H8800VA ---
T8800VA ---
H8800V/H8800VA
T8800V/T8800VA
6.3
5.0
9.7
2.0
9.0
14.5
4.2
5.0
9.7
2.0
9.0
14.5
BODY
A Single pole
Panel cut-out Bezel
A Single pole - Twin
Panel cut-out Bezel
Panel thickness Dim X
0.75-1.24 19.1/19.2
1.25-1.99 19.3/19.4
2.00-3.00 19.7/19.8
Dimensions (mm)
8800VA (H terminals shown)
OPTIONS
Cut-outs must be punched in the direction of insertion
6.2
6.3
6.8
6.9
17.4
17.5
X
*
*
*Optional profile for orientation
*Optional profile for orientation
21.0
15.5
9.9
10.0
X
13.4/
13.5
17.4
17.5
*
*
Actual Size
H Slotted for custom adaptors
R Semi-rotary (not lit)
D Paddle lever (not lit)
V Curved (not lit)
V Curved (lit)
X Two colour (not lit)
A Softline lens
PPush button operation
(8500 only)
See drawing opposite
tel: +44 (0)20 8979 3232 • Arcolectric • email: info@arcoswitch.co.uk
10
TERMINAL FUNCTION ROCKER BODY PRINT, COLOUR, VOLTAGE ETC
H8550 V B
---
ON OFF Switches are ON when pressed over terminal 1
8550
8503
8500 Rocker Switches - Miniature 10A 250Vac Single & Double Pole
ROCKERFUNCTION
Approvals &
ratings vary
with function
ON - OFF
Single pole
(Uses terminals 1a & 2a)
ON (lit) - OFF
Double pole
Indicator
ON (lit) - OFF
Single pole
ON - OFF
Double pole
TERMINAL
8553
8500
8580
Available with
H terminals only
H
4.8 x 0.8
K
2.8 x 0.8
L
2.8 x 0.8
Right angle version of K terminal
available on 8500 only
R
4.8 x 0.8
T
Solder
8.5
4.5
1.5
3.1
Slots for
snap-in buttons
10(6)A 250Vac T125 (non lit types)
6(4)A 250Vac T125 5E4 (50,000 Operations) (non lit types)
10(6)A 250Vac T100 (lit types)
UL CSA 15A Non Ind 250Vac, 14A Ind 250Vac, 10A 277Vac
UL CSA 250Vac 1/2hp, 125Vac 1/4hp
UL 105˚C, file E45221, CSA file LR10990
Inrush 85A to EN61058-1 & 10A 28Vdc
RoHS compliant
3mm contact gap.
Technical data on pages 4 & 5 (switches), 66 (indicators).
1a
3b
2a
4b
8.5
2.6
1.5
3.2
2.6
8.5
3.5
R1.0
R0.8
In house test
Miniature rocker switch
Ratings up to 15A,
250Vac
High in-rush tolerance
Single & double pole in
same body size
Illuminated & non-
illuminated
Matching indicators
Industry standard panel
cut-out
Rotary and push button
accessories
RoHS
tel: +44 (0)20 8979 3232 • Arcolectric • email: info@arcoswitch.co.uk
11
Finish
Matt finish only.
Colour
Call factory for custom colours.
A full range is available for large orders.
Legend printing
Select from the examples or call the factory
for custom legends.
Lamp voltage
Call factory for details of available voltages.
Protective cover L167
(designed to IP65)
Snaps on to bodies with V or X style
rockers and A style lens, this reduces
maximum acceptable panel thickness to
2.2mm.
Examples of printing
CL076 CL080
H8553VB ---
T8553VB ---
H8550XB ---
T8550XB ---
H8580AB ---
T8550HB ---
H8550HB ---H8500VB ---
T8500VB ---
H8550RB Semi-rotary
A splash proofing option
H8500PO ---
BODY
B
Standard body with terminal barrier
Panel cut-out Bezel
BC
Body without terminal barrier
Panel cut-out Bezel
Dimensions for snap-in fixing
Panel
thickness Dim X
0.75-1.25 19.1/19.2
1.25-2.00 19.3/19.4
2.00-3.00 19.7/19.8
DIMENSIONS (mm)
5.1
22.5
9.0
2.0
9.0
14.0
6.0
9.5
OPTIONS
21.0
15.0
X
12.9
21.0
15.0
X
12.9
“B” body with barrier for
H, T and K terminals
5.1
16.0
4.5
2.0
9.0
14.0
“BC” body w/o barrier primarily
for L or R terminals
(can be used for all terminals)
Cut-outs must be punched in the direction of insertion
H8550VB ---
T8550VB ---
23.2
max
20.5
max
12.7 9.5
18.0
23.3
5.0
8.0
12.0
‘PO’ Actuator and body - push button function (8500 only)
12
tel: +44 (0)20 8979 3232 • Arcolectric • email: info@arcoswitch.co.uk
TERMINAL FUNCTION ROCKER BODY PRINT, COLOUR, VOLTAGE ETC
H8653 V B
---
V Curved
V Curved (lit)
D Paddle lever
(Single pole non-lit only)
F Flat
Indicator only (Single pole)
8600 Rocker Switches - Miniature 10A 250Vac Single & Double Pole
ROCKERFUNCTION
Approvals &
ratings vary
with function
ON OFF Switches
are ON when pressed
over terminal 3
ON - OFF
8600
10(4)A
16A 250V, 10A 277V
1/2HP 277V, 1/4HP 125V
8650
10(4)A
10A 277V
1/2HP 277V, 1/4HP 125V
ON - OFF
(momentary ON)
8601
6(1)A
16A 250V, 6A 277V
8651
6(1)A
6A 277V
ON - OFF
(momentary OFF)
8602
10A
16A 250V, 10A 277V
8652
10(4)A
6A 277V
ON - OFF
Lit
N/A 8653
10(4)A
6A 277V
ON - ON
8610
6(1)A
10A 277V
1/2HP 277V, 1/4HP 125V
8660
6(1)A
10A 277V, 1/2HP 277V
1/2HP 277V, 1/4HP 125V
ON - OFF
(momentary 1 side)
8611
6A 277V
8661
6A 277V
ON - OFF - ON
8620 µ
See page 14
8670 µ
See page 14
Indicator
8630
TERMINAL
H
4.8 x 0.8
T
3.5 x 0.8
Solder
X
PCB
0.8 Sq
Y
Right angle PCB
1.3 x 0.8
Contact the factory for details
Double Pole switches with “X”
terminals are supplied without
terminal barriers
7.4
10(4)A 250Vac T90 (unless noted below)
UL CSA See ratings below
UL 65˚C, file E45221, CSA file LR10990
Inrush 25A to EN61058-1 & 10A 28Vdc
RoHS compliant
3mm contact gap except where marked µ.
Technical data on pages 4 & 5 (switches), 66 (indicators).
6.4
O/ 2.2
5.3
3.7
6.0
2
13
2
13
5
46
In house test
Miniature rocker switch
Ratings up to 16A,
250Vac
Single & double pole
ON/OFF, C/O, biased and
centre off switching
Push on, solder and PCB
terminals
Illuminated and non-
illuminated
Matching indicators
Bezel size
single: 21 x 15
double: 21 x 24
RoHS
13
tel: +44 (0)20 8979 3232 • Arcolectric • email: info@arcoswitch.co.uk
Examples of printing
CL142 CL059 CL058
CL076 CL080 CL141
H8600VB ---
T8600VB ---
H8600VB ---
T8600VB ---
H8660VB ---
T8660VB --- T8653VB ---
H8630FB ---
T8630FB ---
H8653VB ---H8650VB ---
T8650VB ---
Finish
Matt finish only.
Colour
Call factory for custom colours.
A full range is available for large orders.
Legend printing
Select from the examples or call the factory
for custom legend.
Lamp voltage
Call factory for details of available voltages.
Blanking plate A8634FB
Dummy unit to fill unused panel holes.
Single pole size only.
Protective covers
L167 for SP
L180 for DP
(designed to IP65)
Snap on to bodies with V rocker or F lens, this
reduces maximum acceptable panel thickness
to 2.2mm.
Single Pole options
Most switches shown can have single pole
switching in double pole bodies.
BODY
B Single pole
Panel cut-out Bezel
Single Pole dimensions for snap-in fixing
Panel thickness Dimension X
0.75-1.24 19.1/19.2
1.25-1.99 19.3/19.4
2.00-3.00 19.7/19.8
B (Double Pole) with terminal barrier
BC (Double Pole) w/o terminal barrier
Panel cut-out Bezel
Double Pole dimensions for snap-in fixing
Panel thickness Dimension X
0.75-1.24 19.1/19.2
1.25-1.99 19.3/19.4
2.00-3.00 19.7/19.8
DIMENSIONS (mm)
Single pole Double pole
5.8
12.5
2.0 7.4
7.0
7.0
OPTIONS
21.0
15.0
X
12.9
21.0
24.0
X
21.9
Terminals shown
are “H” 4.8 push on type
For 8620 and 8670 dimensions see page 14
5.8
19.8
to barrier
2.0
12.5
7.0
7.0
Terminal spacing
10.2 between pole centres
Cut-outs must be punched in the direction of insertion
14
TERMINAL FUNCTION ROCKER BODY PRINT, COLOUR, ETC
H8620 V B - - -
CL141 CL142
Examples of printing
tel: +44 (0)20 8979 3232 • Arcolectric • email: info@arcoswitch.co.uk
H8620VB - - - H8670VB - - -
T8620VB - - - T8670VB - - -
Finish
Matt finish only.
Colour
Call factory for custom
colours.
A full range is available for
large orders.
Legend printing
Select from the examples
or call factory for custom
legends.
Protective covers
IP65
L167 for SP
L180 for DP
(designed to IP65)
Snaps on to body, this
reduces maximum
acceptable panel thickness
to 2.2mm.
8620 & 8670 Rocker Switches - 3 Positions 10A 250Vac
OPTIONSFUNCTION
V Curved B Single pole
Panel thickness Dim X
0.75-1.24 19.1/19.2
1.25-1.99 19.3/19.4
2.00-3.00 19.7/19.8
B Double pole
Panel thickness Dim X
0.75-1.24 19.1/19.2
1.25-1.99 19.3/19.4
2.00-3.00 19.7/19.8
8620
ON - OFF - ON
Single pole
ROCKER BODYTERMINAL
H
4.8 x 0.8
T
Solder
X
PCB 0.8sq
Double pole switches with X
terminals are supplied without
terminal barriers
8.5
10(4)A 250Vac T90
UL CSA 15A 277Vac (Single pole)
UL CSA 250Vac 1/2hp (Single pole)
UL CSA 125Vac 1/4hp (Single pole)
UL CSA 10A 277Vac (Double pole)
UL CSA 125/250Vac 1/2hp (Double pole)
UL CSA 277Vac 1/2hp (Single & Double pole)
UL 90˚C, file E45221, CSA file LR10990
10A 28Vdc
RoHS compliant
µ contact gap.
Technical data on pages 4 & 5.
6.4
O/ 2.15
8.0
4.0
Dimensions (mm)
8620VB (H terminals shown) 8670VB (H terminals shown) 8670VB (X terminals shown)
8670
ON - OFF - ON
Double pole
213
5b
4b 6b
2a1a 3 a
15.0
2.0
8.5
7.0
Ctrs
14.0
X
12.9
21.0
15.0
21.0
24.0
X
21.9
15.0
2.0
8.9
7.0
Ctrs
14.0
10.2
Ctrs
15.0
2.0
8.0
7.0
Ctrs
14.0
10.2
Ctrs
Cut-outs must be punched in the direction of insertion
In house test
3 position miniature
rocker switch
Ratings up to 15A,
250Vac
Single & double pole
Centre off switching
Push on, solder and PCB
terminals
Matching indicators
Bezel size
single: 21 x 15
double: 21 x 24
RoHS
Finish
Matt finish only.
Colour
Call factory for custom
colours.
A full range is available for
large orders.
Legend printing
Select from the examples
or call factory for custom
legends.
TERMINAL FUNCTION ROCKER BODY PRINT, COLOUR, ETC
C1250 A P - - -
CL085 CL086
C1250AP - - - C1250AN - - -
Examples of printing
tel: +44 (0)20 8979 3232 • Arcolectric • email: info@arcoswitch.co.uk
15
1250 Rocker Switches 10A 250Vac
OPTIONSFUNCTION
On when pressed over terminal 1
A Curved
Shown in N body
Shown in P body
N
Panel thickness Dim X
0.75-1.24 26.1/26.2
1.25-1.99 26.3/26.4
2.00-3.00 26.7/26.8
P
Panel thickness
0.75-3.00
1250
ON - OFF
Double pole
Poles are 9.0mm
between centres.
ROCKER BODYTERMINAL
C
6.3 x 0.8
X
PCB 0.8sq
(N body only)
9.0
10(6)A 250Vac T100
6A 400Vac T100
1A 30Vdc
UL CSA 10A 250Vac
UL CSA 16A 250Vac Resistive
UL CSA 125Vac 1/2hp
UL CSA 1A 30Vdc
UL 100˚C, file E45221, CSA file LR10990
Inrush 75A to EN61058-1 & 10A 28Vdc
RoHS compliant
3mm contact gap
Technical data on pages 4 & 5
9.0
5.2
Dimensions (mm)
1250AN (C terminals shown) 1250AN (X terminals shown) 1250AP (C terminals shown)
2a
1a
2
1
1250SP
ON - OFF
Single pole
1a 1
2
1
2a
1a
On when pressed over terminal 1
11a
11.0 21.0
Sub-panelFacia
10.6
9.8
4.0
6.0 26.0
Panel
10.6
9.8
4.0
11.0 17.0
Sub-panelFacia
10.6
4.0 3.2
29.5
15.0
29.5
13.0
13.1
nom
23.8
nom
R3.5
12.4/
12.5
X
12.4/
12.5
27.2/
27.3
Panel cut-out Bezel
Panel cut-out Bezel
Sub-panel Facia
Cut-outs must be punched in the direction of insertion
In house test
Standard rocker switch
Double pole in single
pole body
Snap in or sub panel
mount
Integral terminal barrier
Push on or PCB
terminals
High inrush tolerance
Bezel size:
29.5 x 15mm (snap in)
23.5 x 13mm (sub panel
mount)
RoHS
16
TERMINAL FUNCTION ROCKER BODY PRINT, COLOUR, VOLTAGE ETC
C6003 A L
---
tel: +44 (0)20 8979 3232 • Arcolectric • email: info@arcoswitch.co.uk
C
6.3 x 0.8
H
4.8 x 0.8
S
Screw & Clamp
N/A for assemblies
with 3 terminals
European 16(4)A 250Vac T125, 10A 400Vac T125
UL CSA 20A 277Vac, 250Vac 11/2hp, 125Vac 1hp
UL 100˚C, file E45221, CSA file LR10990
Inrush 150A* to EN61058-1 (ON - OFF only)
20A 28Vdc
*applies to non-momentary types
RoHS compliant
3mm contact gap with Positive Break switching.
Call factory for IP details.
Technical data on pages 4 & 5 (switches), 66 (indicators).
A Softline
Matt
A Softline
Matt
P Lit window
Matt
A Lens
Matt (6030 indicator only)
6000 SP Splashproof Rocker Switches 16A 250Vac
ROCKERFUNCTION
Approvals & ratings vary with function
ON OFF Switches - ON when pressed over terminal 3
TERMINAL
6000 ON - OFF
9.7
9.7
9.7
12 3
6001 ON - OFF (momentary ON)
6002 ON - OFF (momentary OFF)
6003 ON - OFF Lit
6008 ON - OFF Lit (Unswitched neutral)
6009 ON - OFF (momentary ON) Lit
(Unswitched neutral)
6010 ON - ON
6011 ON - ON (momentary 1 side)
6030 Indicator
For twin switches and double pole circuits see pages 18 & 19
Lit
In house test
Single pole
Ratings up to 20A,
277Vac
High in-rush (ON-OFF
types)
Positive switch action
Distinctive styling
Illuminated & non-
illuminated
Matching indicator
Bezel size:
31.5 x 14mm
RoHS
EN1224 EN1223
Examples of printing
C6000AL --- C6000AL ---
C6003PL ---
C6010AL ---
C6030AL ---
C6003AL ---
17
Finish Matt is standard.
Colour Call factory for custom colours.
A full range is available for large orders.
Legend printing Select from the examples or
call factory for custom legends.
Lamp voltage Call factory for details.
Protective cover (designed to IP65)
A snap on cover is available (add G after body
code),this reduces maximum acceptable panel
thickness to 2mm.
Panel sealing washer W46 is available, this
reduces maximum acceptable panel thickness to
1.2mm. Covers are not suitable for momentary
types.
For all options call the factory.
tel: +44 (0)20 8979 3232 • Arcolectric • email: info@arcoswitch.co.uk
L
Panel cut-out ** Bezel
BODY DIMENSIONS (mm)
OPTIONS
2.0 30.0
10.0
8.0
2A 1A
11.1/11.0
30.1/
30.0
14.0
31.5
R2.0
Panel thickness
L0.75 to 2.5mm
** For cut-out details
on momentary switches
call the factory
Cut-outs must be punched in the direction of insertion
For IP65 see “options” below
Integral Splashproofing
Current carrying parts are protected from moisture.
Droplets which may enter the switch are channelled out
through ports in the switch body.
18
TERMINAL FUNCTION ROCKER BODY PRINT, COLOUR, VOLTAGE ETC
C6053 A L
---
tel: +44 (0)20 8979 3232 • Arcolectric • email: info@arcoswitch.co.uk
C
6.3 x 0.8
H
4.8 x 0.8
S
Screw & Clamp
N/A for assemblies
with 3 terminals in either pole
A Softline
Matt
A Softline
Matt
P Lit Window
Matt
6050 DP Splashproof Switches - & Twins #16A 250Vac
ROCKERFUNCTION
Approvals & ratings vary with function
ON OFF Switches - ON when pressed over terminals 3 & 6
TERMINAL
6050 ON - OFF
9.7
9.7
9.7
12 3
45 6
6060 ON - ON
6051 ON - OFF
(momentary ON)
6061 ON - ON
(momentary 1 side)
6062 2 Circuit ON - ON
In house tests only
6052 ON - OFF
(momentary OFF)
6066 ON - ON (Single pole)
(isolated light)
6053 ON - OFF
Lit
6067 ON - ON
Lit
ON - OFF
6054 (momentary ON)
Lit
6068 ON - ON 1pole
ON - OFF Lit 1pole
ON - OFF (Single pole)
6055 (momentary ON)
Lit
6090 ON - OFF 1pole
ON - OFF Lit 1pole
6056 ON - OFF (Single pole)
Isolated light
ON - OFF
6091 (momentary ON)
Lit
6057 ON - OFF
Isolated light
ON - OFF 1 pole
6092 ON - ON 1 pole
Lit
6058 ON - OFF (Single pole)
Lit
ON - OFF (Single pole)
6059 (momentary ON
Isolated light)
Circuits are Double Pole
unless described otherwise
European 16(4)A 250Vac T125, 10A 400Vac T125
UL CSA 20A 277Vac, 250Vac 11/2hp, 125Vac 1hp
UL 100˚C, file E45221, CSA file LR10990
Inrush 150A* to EN61058-1
8(8)A 250Vac T125 5E4 on 6050 only
20A 28Vdc
*applies to non-momentary types
RoHS compliant
3mm contact gap with Positive Break switching.
# Call factory for IP details on Twin units.
Technical data on pages 4 & 5 (switches), 66 (indicators).
Patent app.
In house test
Lit Window
Lit
Water thru design
Ratings up to 20A,
277V ac
High in-rush (ON-OFF
types)
Positive switch action
Distinctive styling
Illuminated & non-
illuminated
Double pole
Bezel size:
31.5 x 25mm
RoHS
EN1196 EN1197
Examples of printing
C6050AL --- C6053AL ---
C6003P/C6003PL
C6053PL ---
C6003P/C6030AL
C6000A/C6000AL
19
Finish Matt is standard.
Colour Call factory for custom colours.
A full range is available for large orders.
Legend printing Select from the examples or
call factory for custom legends.
Lamp voltage Call factory for details.
Protective cover (designed to IP65 #)
The 6050 series is a water thru design.
For a higher level of sealing, a snap on cover is
available (add G after body code). This reduces
maximum acceptable panel thickness to 2mm.
Panel sealing washer W42 is available, this
reduces maximum acceptable panel thickness to
1.2mm. Covers are not suitable for momentary
types.
IP Ratings Call the factory for details.
Terminal Link P1067 connects the poles of a
double pole switch or twin unit.
# Mounting orientation may affect IP rating.
For all options call the factory.
tel: +44 (0)20 8979 3232 • Arcolectric • email: info@arcoswitch.co.uk
L Double pole
Panel cut-out * Bezel
L Twin units
Contact factory for information on
splashproofing and IP ratings
Panel cut-out * Bezel
BODY DIMENSIONS (mm)
OPTIONS
Panel thickness
L 0.75 to 3.0mm
* For cut-out details on
momentary switches
call the factory
Terminal spacing - Poles 10.5 between centres
2.0 30.0
10.0
8.0
5B 4B
22.2/22.1
30.1/
30.0
25.0
31.5
R2.0
22.2/22.1
30.1/
30.0
25.0
31.5
R2.0
For IP65 see options below
Splashproof to IP44
Current carrying parts are protected from moisture.
Droplets which may enter the switch are channelled out through
ports in the switch body
Cut-outs must be punched in the direction of insertion
A Softline Matt
B Splashproof (with Arcshield)
H Slotted (for custom Adaptors)
not momentary
V Curved Matt or gloss
W Splashproof (with Arcshield)
X Two colour Matt
ON - OFF only (not momentary)
F Flat lens Gloss (0430 only)
A Softline lens Matt (0430 only)
as F but with raised profile
20
TERMINAL FUNCTION ROCKER BODY PRINT, COLOUR, VOLTAGE ETC
C1300 A L
---
tel: +44 (0)20 8979 3232 • Arcolectric • email: info@arcoswitch.co.uk
ON - OFF
1500 Standard & 1300 High Inrush Switches 150A to EN61058-1and 16A 250Vac
ROCKERFUNCTION
Approvals & ratings vary with function
ON OFF Switches - ON when pressed over terminal 1
TERMINAL
Standard
1500
ON - OFF
(momentary ON)
1501
HP rating N/A
C
6.3 x 0.8
H
4.8 x 0.8*
K
2.8 x 0.8*
T
Solder
U
Right angle “T” solder terminal
X
PCB 0.8Sq*
*N/A for 1300 series
9.1
7.0
Ø2.1
1500 Series 16(4)A 250Vac T125
UL CSA 16A Non Ind 250Vac, (2 posn) 250Vac 1hp, 125Vac
1/2hp, (3 posn) 250Vac 1/2hp, 125Vac 1/4hp
UL 10A 14Vdc T (1500 and 1510 only)
UL 85˚C, file E45221, CSA file LR10990
20A 28Vdc
1300 series 16(6)A 250Vac T125 5E4 (50,000 Ops.) 150A
Inrush to EN61058-1
UL CSA 20A 250Vac 1hp, 125Vac 1/2hp
UL 85˚C, file E45221, CSA file LR10990
20A 28Vdc
RoHS compliant
3mm contact gap except if marked µ.
Technical data on pages 4 & 5 (switches), 66 (indicators).
9.1
9.1
2.0
1.2
3.2
Ø2.1
9.1
4.0
12 3
ON - OFF
(momentary OFF)
1502
HP rating N/A
ON - ON
1510 µ
HP rating N/A
ON - ON
(momentary 1 side)
1511 µ
HP rating N/A
ON - OFF - ON
1520 µ
125V & 250V 1/2 HP
H terminal rated
T100 only
ON - OFF - ON
(momentary 1 side)
1521 µ
HP rating N/A
H terminal rated
T100 only
ON - OFF - ON
(momentary 2 sides)
1522 µ
HP rating N/A
H terminal rated
T100 only
Indicator
Technical data on page 66
0430
X terminal N/A
In house test
In house test
Matt
Matt
High Inrush
1300
Approvals apply to C & T
terminals only
Standard rocker switch
Non-illuminated
1300 high in-rush current
Choice of switching
circuits including 3
position
Choice of bezel styles
Choice of panel cut outs
Matching indicator
Single pole
Splashproof option
Bezel size A’ style
30.2 x 14.0
RoHS
Finish Matt is standard.
Colour Call factory for custom colours.
A full range is available for large orders.
Legend printing Select from the examples or
call factory for custom legends.
Lamp voltage Call factory for details.
Blanking plates A0434 - - Dummy units to
fill unused panel holes.
Protective cover (designed to IP65)
Snaps on to A, L, Q or T bodies (add G after body
in cat no.), this reduces maximum acceptable
panel thickness to 2mm.
Panel sealing washer W46 is available for the
same body sizes,this reduces maximum
acceptable panel thickness to 1.2mm.
Covers are not suitable for momentary types.
For all options call the factory.
21
Examples of printing
EN602A EN730 EN822
C1500AL ---
T1500AL ---
C1500AR ---
T1500AR ---
C1520AL ---
T1520AL ---
C1500XL ---
T1500XL ---
C0430AL ---
T0430AL ---
C1510AL ---
T1510AL ---
tel: +44 (0)20 8979 3232 • Arcolectric • email: info@arcoswitch.co.uk
A
Gloss or Matt
B
Matt only
L
Matt only
Q
Gloss or Matt
R
Matt only
T
Matt only
BODY DIMENSIONS (mm)
Panel cut-out *Bezel
OPTIONS
12.2/12.3
27.2
27.3
11.0/11.1
30.0
30.1
11.5/11.6
28.2
28.3
11.5/11.6
28.2
28.3
14.0/14.1
28.5
28.6
11.0/11.1
30.0
30.1
14.0
30.2
14.0
33.4
R3.5
14.0
32.0
R1.0
14.0
30.2
R1.6
17.0
31.5
14.0
30.2
R1.6
Cut-outs must be punched in the direction of insertion
feather-edge seal
collar
Enhanced Splashproofing
1500 W and B splashproof options
Feather edge seals and a close fitting collar protect current
carrying parts from moisture.
B option has Hytrel collar/seals for enhanced protection.
Panel thickness
A,Q 0.75 to 3.3mm
L,B,T 0.75 to 2.5mm
R 0.75 to 3.0mm
* For cut-out details
on momentary switches
call the factory
2.0 25.3 Max
9.2
13.2
7.6
plunger tube
1300 High inrush, positive break switching
The 1300 series mechanism ensures
contact welds formed at switch-on,
are positively separated by the
plunger tube acting directly on the
step in the moving contact.
step
22
TERMINAL FUNCTION ROCKER BODY PRINT, COLOUR, VOLTAGE ETC
C5503 A L
---
tel: +44 (0)20 8979 3232 • Arcolectric • email: info@arcoswitch.co.uk
A Softline (Matt only)
P Lit window (Matt only)
ON - OFF
ON - OFF
Lit
Unswitched neutral
5500 Lit Rocker Switches - Single Pole 16A 250Vac
ROCKERFUNCTION
Approvals & ratings vary with function
ON OFF Switches - ON when pressed over terminal 3
TERMINAL
5500 µ
5508 µ
for special
applications
C
6.3 x 0.8
H
4.8 x 0.8
T
Solder
9.1
7.0
Ø2.1
16(4)A 250Vac T85
10(3)A 250Vac T100, (12A 250Vac T125 for P rocker only)
UL CSA 15A 250Vac, CSA 16A Non Ind 250Vac
UL CSA 250Vac 1hp, 125Vac 1/2hp
UL 85˚C, file E45221, CSA file LR10990
Inrush 24A to EN61058-1 & 20A 28Vdc
RoHS compliant
µ contact gap.
Technical data on pages 4 & 5 (switches), 66 (indicators).
For Twin units repeat the order details for both the left and right sides.
9.1
12 3
ON - OFF
Lit
Switched neutral
5503 µ
preferred option
In house test
Lit
Standard rocker switch
Illuminated
Choice of switching
circuits
Choice of bezel styles
Choice of panel cut outs
Matching indicator
Single pole
Splashproof option
Bezel size A’ style
30.2 x 14.0
RoHS
23
Examples of printing
EN3036 EN3064 EN706
C5503AL --- C5500AL ---
C5503A/C5503AL
C5503PL ---
C5503P/C5503PL
C5503A/C5430AL
Finish Matt is standard.
Colour Call factory for custom colours.
A full range is available for large orders.
Legend printing Select from the examples or
call factory for custom legends.
Lamp voltage Call factory for details.
Blanking plate A0434 - - (SP) A0494 - - (DP)
Dummy units to fill unused panel holes.
Protective cover (designed to IP65)
Snaps on to A, L, Q or T bodies (add G after body
in cat no.), this reduces maximum acceptable
panel thickness to 1.2mm.
Panel sealing washers W46 (Single Pole) and
W42 (Double Pole) are available for these body
types, this reduces maximum acceptable panel
thickness to 2mm.
For all options call the factory.
tel: +44 (0)20 8979 3232 • Arcolectric • email: info@arcoswitch.co.uk
APanel cut-outs Bezel
Matt only
B
Matt only
L
Matt only
Q
Matt
R
Matt only
T
Matt only
BODY DIMENSIONS (mm)
OPTIONS
Panel thickness
A,Q 0.75 to 3.3mm
L,B,T 0.75 to 2.5mm
R0.75 to 3.0mm
7.6
2.0 28.6 Max
9.2
13.2
12.2/12.3
27.2
27.3
11.0/11.1
30.0
30.1
11.5/11.6
28.2
28.3
11.5/11.6
28.2
28.3
14.0/14.1
28.5
28.6
11.0/11.1
30.0
30.1
14.0
30.2
14.0
33.4
R3.5
14.0
31.9
R1.0
14.0
30.2
R1.6
17.0
31.5
14.0
30.2
R1.6
Twin units
Two single switches or a switch and an indicator light can be
assembled side by side in one double pole body.
For 5500 range panel cut-out details (L, B and T) call factory.
For twin units the first set of order format details refer to the
left hand unit, when looking at the front of the assembly.
(This has terminal numbers 1, 2 & 3)
1
2
3
4
5
6
1
2
3
4
5
6
Terminal spacing - Poles 10.8 between centres (twin units)
Cut-outs must be punched in the direction of insertion
TERMINAL FUNCTION ROCKER TERMINAL FUNCTION ROCKER BODY PRINT, COLOUR, ETC
C1500 A/C1510 A L
---
24
tel: +44 (0)20 8979 3232 • Arcolectric • email: info@arcoswitch.co.uk
16(4)A 250Vac T125
UL CSA 16A 250Vac
UL CSA (2 posn) 250Vac 1hp, 125Vac 1/2hp, (3 posn) 250 Vac
1/2hp, 125Vac 1/4hp
UL 85˚C, file E45221, CSA file LR10990
Inrush 36A to EN61058-1 & 20A 28Vdc
For versions with High Inrush or for 50,000 operations, see pages 20
and 26.
RoHS compliant
3mm contact gap except where marked µ.
Technical data on pages 4 & 5 (switches), 66 (indicators).
For twin units repeat the order details for both the left and right sides.
ON - OFF
ON - ON
ON - OFF - ON
Indicator
Technical data on page 66
A Softline (Matt)
B Softline splashproof (Matt)
W Curved splashproof (Matt)
X Two colour (Matt) (not momentary)
ON - OFF only
A Softline lens (Matt) (Indicator)
1500 Twin Units Switches and Indicators 16A 250Vac
ROCKERFUNCTION
Approvals & ratings vary with function
ON OFF Switches - ON when pressed over terminal 1 or 4
TERMINAL
1500
1510 µ
HP rating N/A
1520 µ
125V & 250V 1/2 HP
H terminal rated T100 only
0430
X terminal N/A
C
6.3 x 0.8
H
4.8 x 0.8
K
2.8 x 0.8
T
Solder
X
PCB 0.8Sq
9.1
7.0
Ø2.1
9.1
9.1
2.0
1.2
9.1
4.0
12 3
45 6
In house test
Twin unit rocker switch
Choice of switching
circuits including 3
position
Push-on, solder and
PCB terminals
Choice of bezel styles
Choice panel cut outs
Matching indicator
Single pole
Splashproof option
Bezel size A’ style
30.2 x 25.0
RoHS
Finish Matt is standard.
Colour Call factory for custom colours.
A full range is available for large orders.
Legend printing Call factory for custom
legends. State if a legend is to appear on the left
or right hand unit (viewed from the front).
Lamp voltage Call factory for details.
For all options call the factory.
Examples of printing
EN602A EN730
C1500A/C1500AL C1500A/C0430AL
C1500A/C1520AL
C1500X/C1500XL
C0430A/C0430AL
C1520A/C1510AL
25
tel: +44 (0)20 8979 3232 • Arcolectric • email: info@arcoswitch.co.uk
A Panel cut-outs Bezel
Gloss or Matt
B
Matt only
L
Matt only
Q
Gloss or matt
R
Matt only
T
Matt only
BODY DIMENSIONS (mm)
OPTIONS
Twin unit terminal numbering
The first 6 digits of the catalogue number refer to the left hand
unit when looking at the front. (This has terminal nos. 4, 5 & 6).
22.3/22.4
27.2
27.3
22.1/22.2
30.0
30.1
22.3/22.4
28.2
28.3
22.3/22.4
28.2
28.3
23.0/25.4
28.4
28.5
22.1/22.2
30.0
30.1
25.0
30.2
25.0
33.4
R3.5
32.0
25.0
R1.0
25.0
30.2
R1.6
28.9
33.2
30.2
25.0
R1.6
Panel thickness
A,Q 0.75 to 3.3mm
L,B,T 0.75 to 2.5mm
R0.75 to 3.0mm
2.0 25.3 Max
9.2
13.2
7.6
Call the factory for terminal spacing details
feather-edge seal
collar
Enhanced Splashproofing
1500 W and B splashproof options
Feather edge seals and a close fitting collar protect current
carrying parts from moisture.
B option has Hytrel collar/seals for enhanced protection.
Cut-outs must be punched in the direction of insertion
26
A Softline Matt
B Splashproof Softline
V Curved
W Splashproof Curved
P Lit window Matt
X Two colour Matt
F Flat lens Gloss (0480 only)
A Softline lens Matt (0480 only)
as F but with raised profile
R Round
TERMINAL FUNCTION ROCKER BODY PRINT, COLOUR, VOLTAGE ETC
C1553 A L
---
tel: +44 (0)20 8979 3232 • Arcolectric • email: info@arcoswitch.co.uk
1550 Series 16(4)A 250Vac T125
UL CSA 16A 250Vac, (2 posn) 250Vac 1hp, 125Vac 1/2hp,
(3 posn) 250 Vac 1/2hp, 125Vac 1/4hp.
UL 85˚C, file E45221, CSA file LR10990.
20A 28Vdc.
1350 series 16(4)A 250Vac T85 1E4 (10,000 Ops.)
On request 16(6)A 250Vac T125 5E4 (50,000 Ops.)
150A Inrush to EN61058-1.
UL CSA 20A 250Vac 1hp, 125Vac 1/2hp.
UL 72Vdc 7A, 36Vdc 14A.
UL 85˚C, file E45221, CSA file LR10990.
20A 28Vdc
RoHS compliant
3mm contact gap except if marked µ.
Technical data on pages 4 & 5 (switches), 66 (indicators).
ON - OFF
1550 Standard & 1350 High Inrush Switches 150A to EN61058-1 and 16A 250Vac
ROCKERFUNCTION
Approvals & ratings vary with function
ON OFF Switches - ON when pressed over terminal 1
TERMINAL
High Inrush
1350
C
6.3 x 0.8
H
4.8 x 0.8*
K
2.8 x 0.8*
T
Solder
U
Right angle T Solder (Not DP)
X
PCB 0.8Sq*
*Contact factory for details on 1350 series
9.1
7.0
Ø2.1
9.1
9.1
2.0
1.2
3.2
Ø2.1
9.1
4.0
12 3
45 6
In house test
In house test
Standard
1550
ON - OFF
(momentary ON)
1551
HP rating N/A
ON - OFF
(momentary OFF)
1552
HP rating N/A
ON - OFF
Lit
1353
Not W, X or B rocker
1553
Not W, X or B rocker
ON - ON
1560 µ
ON - ON
(momentary 1 side)
1561 µ
HP rating N/A
2 Circuit
ON - ON
1562 µ
In house tests only
ON - OFF - ON
1570 µ
125V & 250V 1/2 HP
H terminal rated T100 only
ON - OFF - ON
(momentary 1 side)
1571 µ
HP rating N/A
H terminal rated T100 only
ON - OFF - ON
(momentary 2 sides)
1572 µ
HP rating N/A
H terminal rated T100 only
3 position selective
OFF - A - A+B
1484 µ
In-house tested to 10(3)A 250Vac
(B rocker only)
3 position selective
A - B - C (link not supplied)
1487 µ
In-house tested to 10(3)A 250Vac
(B rocker only)
Indicator
Technical data on page 66
0480
X terminal N/A
12
4
5
3
6
12
4
5
3
6
12
4
5
3
6
12
4
5
3
6
12
4
5
3
6
12
4
5
3
6
Lit (not momentary)
Lit (not momentary)
Lit (not momentary)
Matt or gloss Gloss only
Top view
(ON OFF only - not momentary)
Standard rocker switch
1350/53 high inrush
Choice of switching
circuits including 3
position
Push-on, solder and
PCB terminals
Choice of bezel styles
Choice of panel cut outs
Matching indicator
Double pole
Splashproof option
Bezel size A’ style
30.2 x 25.0
RoHS
27
Examples of printing
EN602A EN730 EN822
C1350AL ---
C0480AL ---
C1550XL --- C1553PL ---
Finish Matt is standard.
Colour Call factory for custom colours.
A full range is available for large orders.
Legend printing Select from the examples or
call factory for custom legends.
Lamp voltage Call factory for details.
Blanking plates A0494 Dummy units
to fill unused panel holes.
Protective cover (designed to IP65)
Snaps on to A, L, Q or T bodies (add G after body
in cat no), this reduces maximum acceptable
panel thickness to 1.2mm.
Panel sealing washer W42 is available for the
above body sizes, this reduces maximum
acceptable panel thickness to 2mm. Covers are
not suitable for momentary types.
For all options call the factory.
tel: +44 (0)20 8979 3232 • Arcolectric • email: info@arcoswitch.co.uk
C1553RA ---
Shown with M614 bezel cover
C0480RA ---
A
Gloss or Matt
B
Matt only
L
Matt only
Q
Gloss or matt
R
Matt only
T
Matt only
BODY DIMENSIONS (mm)
Panel cut-out * Bezel
OPTIONS
Panel thickness
A,Q 0.75 to 3.3mm
L,B,T 0.75 to 2.5mm
R0.75 to 3.0mm
* For cut-out details on
momentary switches call the
factory.
2.0 25.3 Max
9.2
13.2
7.6
Terminal spacing - Poles 10.2 between centres
22.3/22.4
27.2
27.3
22.1/22.2
30.0
30.1
22.3/22.4
28.2
28.3
22.3/22.4
28.2
28.3
23.0/25.4
28.4
28.5
22.1/22.2
30.0
30.1
25.0
30.2
25.0
33.4
R3.5
32.0
25.0
R1.0
25.0
30.2
R1.6
28.9
33.2
30.2
25.0
R1.6
C1553AA with additional
M616 guard
Cut-out 22.0/22.1 x 29.4/29.5
Guard accepts A body only
Optional snap-in M441 barrier
Cut-outs must be punched in the direction of insertion
plunger tube
1350 High inrush, positive break switching
The 1350 series mechanism ensures
contact welds formed at switch-on,
are positively separated by the
plunger tube acting directly on the
step in the moving contact.
step
R13 Round Rocker Switches 6A 250Vac
PRODUCT
DETAILS DIMENSIONS (mm)
7.1 7.1
8.1
14.5
5.5
123
Ø23.0
2.0
0.9
Ø20.2
2.2
Ø17.0
4.8x0.8
12
12
8
F
12
123
123
123
123
123
Snap fixing into panel thickness up to 3.0
* R13 208F has 12.5mm deep body
*
5.0
8.5
15.8
5.5
12
Ø23.5
2.0
7.8
Ø17.0
only
Double pole
Panel cut-out
Single pole
Miniature round rocker
switch
Ratings up to 10A,
250Vac
Single & double pole
Illuminated & non-
illuminated, neon and
LED
Choice of actuators
Matching indicator
Bezel size:
23mm dia.
RoHS
SP ON - OFF µ
Cat no.
R13 112A AAA
SP ON - OFF µ
Cat no.
R13 112A AAB
SP ON - OFF µ
Lit 230V
Cat no.
R13 112B NAA
SP ON - OFF µ
Lit 230V
Cat no.
R13 112B NAB
DP ON - OFF
Cat no.
R13 244A AAA
tel: +44 (0)20 8979 3232 • Arcolectric • email: info@arcoswitch.co.uk
SP ON - OFF µ
Lit 230V
Cat no.
R13 112B NAC
SP ON - ON µ
Cat no.
R13 112C AAA
SP ON - OFF - ON µ
Cat no.
R13 112D AAA
SP ON - OFF µ
(Momentary ON)
Cat no.
R13 208F AAA*
DP ON - OFF
Lit 230V
Cat no.
R13 244B NAA
28
TERMINAL FUNCTION ROCKER BODY PRINT, COLOUR, VOLTAGE ETC
R13 112A AAA
SP 6A 250Vac T85,
DP 10(4)A 250Vac T85
UL CSA SP 10A 125Vac & 6A 250Vac (For 16A call the factory)
UL CSA DP 8A 125/250Vac
UL 85˚C, file E67774(S)
CSA file LR45128
RoHS compliant
Single pole has µ contact gap.
Technical data on pages 4 & 5.
Standard products
Are supplied with the body and rocker colour, print & lamp voltage shown
in the product illustration and description.
R13 Round Rocker Switches 6A 250Vac
PRODUCT
DETAILS PANEL CUT-OUT (mm)
0.9
Ø20.2
2.2
12
123
12 3+
3
-
13
Snap fixing into panel thickness up to 3.0
approvals - contact the factory
Ø17.0
4.8x0.8
7.1
8.1
14.5
321
Ø23.0
2.0 5.5
Ø17.0
4.8x0.8
7.1 7.1
8.1
14.5
5.5
123
Ø23.0
2.0
Ø15.0
4.8x0.8
7.1 7.1
8.1
14.5
10.0
123
Ø23.0
2.0
Ø17.0
4.8x0.8
14.2
8.1
14.5
4.0
13
Ø23.0
2.0
RoHS
Miniature round
rocker switch
Ratings up to 10A,
250V ac
Single and double
pole
Illuminated and non-
illuminated, neon
and LED
Choice of actuators
Matching indicator
Bezel size:
23mm dia.
Protective cover L188
Snaps on to bodies (not R13 211 or R13 112LP), this
reduces maximum acceptable panel thickness to
2.4mm.
tel: +44 (0)20 8979 3232 • Arcolectric • email: info@arcoswitch.co.uk
SP ON - OFF µ
Bright colour ON signal
Cat no.
R13 112A2 - -
SP ON - OFF µ
Lit Window
Cat no.
R13 112B2 - -
SP ON - OFF µ
Paddle tip has red LED
Cat no.
R13 112LP - -
Indicator light
Cat no.
R9 92B - - -
29
TERMINAL FUNCTION ROCKER BODY PRINT, COLOUR, VOLTAGE ETC
R13 112A2 - -
6A 250Vac T85
UL CSA 10A 125Vac & 6A 250Vac (For 16A call the factory)
UL 85˚C, file E67774(S)
CSA file LR45128
RoHS compliant
Single pole has µ contact gap.
Technical data on pages 4 & 5.
Special products
Are made to order and can be supplied with a range of body and
rocker/lens colours, print & lamp voltage.
Call the factory for availability to your special requirements.