Part Number: 7930A DataTuff(R) 5e, 4 Pr #24 Str BC, PO Ins, PVC Jkt, CMX-Outdoor CMR Product Description Industrial Ethernet Cat 5e, 4 Pair 24AWG (7x32) Bare Copper, PO Insulation, PVC Outer Jacket, CMX-Outdoor CMR Technical Specifications Product Overview Industrial Ethernet Cable, Harsh Environments, Flexible Applications, 200MHz Category 5e, Industrial Patch Cable, Gigabit Ethernet, 100BaseTX, 100BaseVG ANYLAN, 155ATM, 622ATM, NTSC/PAL Component or Composite Video, AES/EBU, Digital Video, RS-422, CMX - Outdoor, RJ-45 Compatible Suitable Applications: Physical Characteristics (Overall) Conductor AWG Stranding 24 7x32 Material No. of Pairs BC - Bare Copper 4 Conductor Count: 8 Total Number of Pairs: 4 Conductor Size: 24 AWG Insulation Material Nominal Wall Thickness PO - Polyolefin 0.008 in Bonded-Pair: No Color Chart Number Color 1 White/Blue Stripe & Blue 2 White/Orange Stripe & Orange 3 White/Green Stripe & Green 4 White/Brown Stripe & Brown Outer Shield Material Material Unshielded Outer Jacket Material Material Nominal Diameter Nominal Wall Thickness Industrial Grade PVC - Polyvinyl Chloride 0.24 in Electrical Characteristics Conductor DCR Max. Conductor DCR Max. DCR Unbalance 9.38 Ohm/1000ft 3% Capacitance Max. Capacitance Unbalance Nom.Mutual Capacitance 330 pF/ft 15 pF/ft 0.03 in Delay Max. Delay Max. Delay Skew Nominal Velocity of Propagation (VP) [%] Typical Delay Skew 510 ns/100m 45 ns/100m 69 % 12 ns/ft High Freq Frequency [MHz] Min. NEXT [dB] Max. Insertion Loss (Attenuation) Min. PSNEXT [dB] Min. ACR [dB] Min. PSACR [dB] Min. ACRF (ELFEXT) [dB] Min. PSACRF (PSELFEXT) [dB] Min. RL (Return Loss) [dB] Min. SRL (Structural Return Loss) Max./Min. Input Impedance (unFitted) Max./Min. Fitted Impedance 1 MHz 2.5 dB/100m 65.3 dB 62.3 dB 62.8 dB 59.8 dB 63.8 dB 60.8 dB 20 dB 23 dB 100 15 Ohm 100 15 Ohm 4 MHz 4.9 dB/100m 56.3 dB 53.3 dB 51.4 dB 48.4 dB 51.7 dB 48.7 dB 23 dB 23 dB 100 15 Ohm 100 15 8 MHz 6.9 dB/100m 51.8 dB 48.8 dB 44.9 dB 41.9 dB 45.7 dB 42.7 dB 24.5 dB 24.5 dB 100 15 Ohm 100 15 10 MHz 7.8 dB/100m 50.3 dB 47.3 dB 42.5 dB 39.5 dB 43.8 dB 40.8 dB 25 dB 25 dB 100 15 Ohm 100 15 16 MHz 9.9 dB/100m 47.3 dB 44.3 dB 37.4 dB 34.4 dB 39.7 dB 36.7 dB 25 dB 25 dB 100 15 Ohm 100 15 20 MHz 11.1 dB/100m 45.8 dB 42.8 dB 34.7 dB 31.7 dB 37.7 dB 34.7 dB 25 dB 25 dB 100 15 Ohm 100 15 25 MHz 12.5 dB/100m 44.3 dB 41.3 dB 21.8 dB 28.8 dB 35.8 dB 32.8 dB 24.3 dB 24.3 dB 100 15 Ohm 100 15 31.25 MHz 14.1 dB/100m 42.9 dB 39.9 dB 28.8 dB 25.8 dB 33.9 dB 30.9 dB 23.6 dB 23.6 dB 100 15 Ohm 100 15 62.5 MHz 20.4 dB/100m 38.4 dB 35.4 dB 18 dB 15 dB 27.8 dB 24.8 dB 21.5 dB 21.5 dB 100 15 Ohm 100 15 100 MHz 26.4 dB/100m 35.3 dB 32.3 dB 8.9 dB 5.9 dB 23.8 dB 20.8 dB 20.1 dB 20.1 dB 100 15 Ohm 155 MHz 33.7 dB/100m 32.5 dB 29.5 dB 19.9 dB 16.9 dB 15.8 dB 100 25 Ohm 200 MHz 38.9 dB/100m 30.8 dB 27.8 dB 17.7 dB 14.7 dB 15 dB 100 25 Ohm Voltage UL Voltage Rating 300 V RMS Temperature Range Installation Temp Range: -25C To +75C UL Temp Rating: 60C Storage Temp Range: -40C To +85C Operating Temp Range: -40C To +75C Mechanical Characteristics Bulk Cable Weight: 26 lbs/1000ft Max Recommended Pulling Tension: 25 lbs Min Bend Radius/Minor Axis: 0.960 in Standards NEC/(UL) Specification: CMR, CMX-Outdoor, UL 444 CEC/C(UL) Specification: CMR ISO/IEC Compliance: ISO/IEC 11801 Cat 5e CPR Euroclass: Eca Data Category: Category 5e ANSI Compliance: ICEA 661 Telecommunications Standards: TIA-568.C.2 Cat 5e, NEMA WC-63.1 Third Party Performance Verification: UL Verified Cat 5e Patch Applicable Environmental and Other Programs EU Directive 2000/53/EC (ELV): Yes EU Directive 2003/11/EC (BFR): Yes EU Directive 2011/65/EU (ROHS II): Yes EU Directive 2012/19/EU (WEEE): Yes EU Directive 2015/863/EU: Yes EU Directive Compliance: EU Directive 2003/11/EC (BFR) EU CE Mark: Yes EU RoHS Compliance Date (yyyy-mm-dd): 2004-01-04 CA Prop 65 (CJ for Wire & Cable): Yes MII Order #39 (China RoHS): Yes Suitability Suitability - Indoor: Yes Suitability - Oil Resistance: Yes Suitability - Outdoor: Yes Suitability - Sunlight Resistance: Yes Flammability, LS0H, Toxicity Testing UL Flammability: UL1666 Riser CSA Flammability: FT4 ISO/IEC Flammability: IEC 60332-1-2 UL voltage rating: 300 V RMS Plenum/Non-Plenum Plenum (Y/N): No Part Number Variants Item # Color UPC Length Footnote 7930A 0101000 Black 612825191575 1,000 ft C 7930A 0102000 Black 612825191582 2,000 ft C Footnote: C - CRATE REEL PUT-UP. Patent: https://www.belden.com/resources/patents Product Notes Notes: Operating temperatures are subject to length de-rating. Cable passes -25C Cold Bend per UL 1581. History Update and Revision: Revision Number: 0.292 Revision Date: 07-11-2019 (c) 2019 Belden, Inc All Rights Reserved. Although Belden makes every reasonable effort to ensure their accuracy at the time of this publication, information and specifications described here in are subject to error or omission and to change without notice, and the listing of such information and specifications does not ensure product availability. Belden provides the information and specifications herein on an "ASIS" basis, with no representations or warranties, whether express, statutory or implied. In no event will Belden be liable for any damages (including consequential, indirect, incidental, special, punitive, or exemplary damages) whatsoever, even if Belden has been advised of the possibility of such damages, whether in an action under contract, negligence or any other theory, arising out of or in connection with the use, or inability to use, the information or specifications described herein. All sales of Belden products are subject to Belden's standard terms and conditions of sale. Belden believes this product to be in compliance with all applicable environmental programs as listed in the data sheet. The information provided is correct to the best of Belden's knowledge, information and belief at the date of its publication. This information is designed only as a general guide for the safe handling, storage, and any other operation of the product itself or the one that it becomes a part of. The Product Disclosure is not to be considered a warranty or quality specification. Regulatory information is for guidance purposes only. Product users are responsible for determining the applicability of legislation and regulations based on their individual usage of the product.