1800/1805 Series
TO-8, 0 psi to 3 psi, 0 psi to
150 psi Silicon Pressure
Sensors
DESCRIPTION
The 1800/1805 Series sensors are high performance TO-8
pressure transducers specifically designed to address a variety
of both low and medium pressure original equipment
manufacture applications.
The transducers offer two performance grades and a variety of
compensation options, including span and calibration to within
±2 mV (normalized output). The 1800/1805 Series can operate
with either constant current or voltage excitation.
The 1800/1805 Series contains a solid state piezoresistive
pressure sensor mounted in a standard TO-8 package. They
are printed circuit board and pin-for-pin compatible with other
TO-8 pressure sensors.
FEATURES
Standard pressure ranges from 0 psi to 3 psi, 0 psi to
150 psi
Gauge, absolute or differential models
Voltage or constant current excitation
Choice of temperature compensation options
Laser trim, normalized output
Laser trim, standard output
Resistor compensation
Uncompensated version available for microprocessor-
based designs
POTENTIAL APPLICATIONS
Instrumentation calibration
Avionics/aerospace
Medical equipment
HVAC
Pneumatic controls
1800/1805 Series
TO-8, 0 psi to 3 psi, 0 psi to 150 psi
2 www.honeywell.com/sensing
ENVIRONMENTAL SPECIFICATIONS (All devices)
Characteristic Parameter Characteristic Parameter
Supply voltage, VS 10 Vdc Insulation resistance 100 MOhm at 50 Vdc
Compensated temperature range -1 °C to 54 °C [34 °F to 129 °F] Humidity 50 % ± 10 %
Operating temperature tange -40 °C to 121 °C [-40 °F to 257 °F] Common-mode pressure 150 psig
Vibration 10 g rms at 20 Hz to 200 Hz Max. soldering temperature 260 °C [500 °F] 10 s max.
Shock 100 g for 11 ms Excitation voltage VS Supply voltage Vs =15 Vdc max.
Life 100 million cycles Excitation current Supply current Is = 2 mA max.
PERFORMANCE CHARACTERISTICS(1)
Characteristic Min. Typ. Max. Unit
Zero pressure offset(1)±0.5 mV
Zero pressure offset (3 psi to 5 only) (1)±1 mV
Full-scale span(2)
Standard output–current excitation 75 150 mV
Standard output–voltage excitation 40 120 mV
Normalized output–current excitation 98 102 mV
Normalized output–current excitation (3 psi only) 73 77 mV
Normalized output–voltage excitation 38 42 mV
Pressure non-linearity(3)±0.15 ±0.20 %FSS
Pressure hysteresis(3)±0.0125 %FSS
Repeatability – ±0.0125 %FSS
Temperature effect on offset(4)±0.5 mV
Temperature effect on offset (3 psi and 5 psi only) (4)±1 mV
Temperature effect on span ±0.5 mV
Temperature effect on span (3 psi and 5 psi only) (4) ±1 mV
Thermal hysteresis ±0.1 %FSS
Response time(5) – – 1 ms
Long term stability of offset and span(6)±0.2 %FSS
Common mode voltage(7)
Standard output–current excitation 50 % input
Standard output–voltage excitation 50 % input
Normalized output–current excitation 35 % input
Normalized output–voltage excitation 25 % input
Input resistance – – – –
Current excitation 2.0 – 8.0 k
Voltage excitation 8.0 40 k
Output resistance 3.5 – 6.0 k
PRESSURE RANGE SPECIFICATIONS
Catalog Listing Pressure Range Top Side Overpressure(8) Bottom Side Overpressure(9)
1805-00 (G,D) - (K,L) (0..4) (M,L,N) 0 psi to 3 psi 15 psi 9 psi
1805-01 (G,D) - (K,L) (0..4) (M,L,N) 0 psi to 5 psi 25 psi 15 psi
1800-02 (G,D) - (K,L) (0..4) (M,L,N) 0 psi to 10 psi 50 psi 30 psi
1800-03 (G,D) - (K,L) (0..4) (M,L,N) 0 psi to 15 psi 65 psi 45 psi
1800-07 (G,D) - (K,L) (0..4) (M,L,N) 0 psi to 30 psi 250 psi 50 psi
1800-08 (G,D) - (K,L) (0..4) (M,L,N) 0 psi to 50 psi 350 psi 50 psi
1800-09 (G,D) - (K,L) (0..4) (M,L,N) 0 psi to 100 psi 350 psi 50 psi
1800-10 (G,D) - (K,L) (0..4) (M,L,N) 0 psi to 150 psi 350 psi 50 psi
Notes:
1. Reference conditions (unless otherwise noted); TA = 25 °C [77 °F], Supply VS = 10 Vdc ±0.01 Vdc or IS = 1.5 mA ±0.0015 mA.
2. Full-scale span (FSS) is the algebraic difference between the output voltage at full-scale pressure and the output at zero pressure. FFS is
ratiometric to the supply voltage.
3. Pressure non-linearity is based on best-fit straight line from the zero to the full-scale pressure. Pressure hysteresis is the maximum output
difference at any point within the operating pressure range for increasing and decreasing pressure.
4. Maximum error band of the offset voltage or span over the compensated temperature range, relative to the 25 °C [77 °F] reading.
5. Response time for a 0 psi to full-scale span pressure step change, 10 % to 90 % rise time.
6. Long term stability over a six month period.
7. Common mode voltage as measured from output to ground. For higher levels of common mode voltage, contact the factory.
8. Pressure overrange: Top: 5 x full-scale pressure or 350 psi, whichever is less.
9. Pressure overrange: Bottom: 3 x full-scale or 50 psi, whichever is less.
Silicon Pressure Sensors
Honeywell Sensing and Control 3
STANDARD COMPENSATION AND TRIM CHOICES
For maximum convenience, the 1800/1805 Series is
temperature compensated from -1 °C to 54 °C [34 °F to
129 °F]. Other temperature ranges are available upon request.
Normalized Output Option: For design convenience and
sensor interchangeability, the 1800/1805 Series is available
with normalized output (100 ±2 mV dc in current excited
versions with pressure range >3 psi). Normalized output for
current excited 3 psi devices is 75 ±2 mV dc.
Laser Trim: Compensation is accomplished by using an in-
house laser trim facility that allows for tighter product
performance control and improved flexibility in response to
special customer performance requirements.
Resistors: This option includes a printout of suggested
temperature compensation and zero offset resistor values for
each individual sensor.
ELECTRICAL CONNECTIONS CURRENT EXCITATION VOLTAGE EXCITATION
Pin 1 on normalized and voltage
excited standard output.
Normalized output shown.
Standard output on pin 5 R6 shorted. R5 open for standard output.
EXTERNAL CONNECTIONS
POSITIVE PRESSURE ON TOP AND BOTTOM SIDES
Current Excitation – Standard Output Voltage Excitation – Standard Output
Current or Voltage Excitation –
Normalized Output
Discrete Resistor Laser Trim Board Discrete Resistor Laser Trim Board Laser Trim Board
Pin Connection Pin Connection Pin Connection Pin Connection Pin Connection
4 + Output 4 + Output 4 + Output 4 + Output 4 + Output
5 + Input 5 + Input 5 + Input 5 NC 5 NC
6 - Input 6 - Input 6 - Input 6 - Input 6 - Input
10 - Output 10 - Output 10 - Output 10 - Output 10 + Output
11 NC 11 NC 11 NC 11 NC 11 NC
12 NC 12 NC 12 NC 12 NC 12 NC
1 + Input 1 + Input
PRESSURE CONNECTION OPTIONS
OPTION 0 OPTION 1 OPTION 2 OPTION 4
Automation and Control Solutions
Sensing and Control
Honeywell
11 West Spring Street
Freeport, Illinois 61032
www.honeywell.com/sensing
008137-2-EN IL50 GLO Printed in USA
October 2005
© 2005 Honeywell International Inc.
ORDER GUIDE
Series
1800/1805
Pressure Range
For Model 1800 For Model 1805
02: 0 psi to 10 psi 00: 0 psi to 3 psi
03: 0 psi to 15 psi 01: 0 psi to 5 psi
07: 0 psi to 30 psi
08: 0 psi to 50 psi
09: 0 psi to 100 psi (G and A only)
10: 0 psi to 150 psi (G only)
Sensor Type
G: Gage
A: Absolute
D: Differential
Excitation
L: Current
K: Voltage
Compensation
L: Laser trimmed, standard output
N: Laser trimmed, normalized output
M: Computer printout of resistor values
1800/1805 02 A L 1 L
Pressure Connections
Top Bottom
0: 3/16 in tube none
1: 3/16 hole 1/8 in tube
2: 3/16 in hole none
4: 3/16 in tube 1/8 in tube
Note:
Transducer recommended for use with non-corrosive, non-condensing gases.
W
ARNING
PERSONAL INJURY
DO NOT USE these products as safety or emergency stop
devices or in any other application where failure of the
product could result in personal injury.
Failure to comply with these instructions could result in
death or serious injury.
WARRANTY/REMEDY
Honeywell warrants goods of its manufacture as being free of
defective materials and faulty workmanship. Honeywell’s
standard product warranty applies unless agreed to otherwise
by Honeywell in writing; please refer to your order
acknowledgement or consult your local sales office for specific
warranty details. If warranted goods are returned to Honeywell
during the period of coverage, Honeywell will repair or replace,
at its option, without charge those items it finds defective. The
foregoing is buyer’s sole remedy and is in lieu of all other
warranties, expressed or implied, including those of
merchantability and fitness for a particular purpose. In no
event shall Honeywell be liable for consequential, special,
or indirect damages.
While we provide application assistance personally, through
our literature and the Honeywell web site, it is up to the
customer to determine the suitability of the product in the
application.
Specifications may change without notice. The information we
supply is believed to be accurate and reliable as of this
printing. However, we assume no responsibility for its use.
W
ARNING
MISUSE OF DOCUMENTATION
The information presented in this product sheet is for
reference only. Do not use this document as a product
installation guide.
Complete installation, operation, and maintenance
information is provided in the instructions supplied with
each product.
Failure to comply with these instructions could result in
death or serious injury.
SALES AND SERVICE
Honeywell serves its customers through a worldwide network
of sales offices, representatives and distributors. For
application assistance, current specifications, pricing or name
of the nearest Authorized Distributor, contact your local sales
office or:
E-mail: info.sc@honeywell.com
Internet: www.honeywell.com/sensing
Phone and Fax:
Asia Pacific +65 6355-2828
+65 6445-3033 Fax
Europe +44 (0) 1698 481481
+44 (0) 1698 481676 Fax
Latin America +1-305-805-8188
+1-305-883-8257 Fax
USA/Canada +1-800-537-6945
+1-815-235-6847
+1-815-235-6545 Fax