1800/1805 Series
TO-8, 0 psi to 3 psi, 0 psi to 150 psi
2 www.honeywell.com/sensing
ENVIRONMENTAL SPECIFICATIONS (All devices)
Characteristic Parameter Characteristic Parameter
Supply voltage, VS 10 Vdc Insulation resistance 100 MOhm at 50 Vdc
Compensated temperature range -1 °C to 54 °C [34 °F to 129 °F] Humidity 50 % ± 10 %
Operating temperature tange -40 °C to 121 °C [-40 °F to 257 °F] Common-mode pressure 150 psig
Vibration 10 g rms at 20 Hz to 200 Hz Max. soldering temperature 260 °C [500 °F] 10 s max.
Shock 100 g for 11 ms Excitation voltage VS Supply voltage Vs =15 Vdc max.
Life 100 million cycles Excitation current Supply current Is = 2 mA max.
PERFORMANCE CHARACTERISTICS(1)
Characteristic Min. Typ. Max. Unit
Zero pressure offset(1) – – ±0.5 mV
Zero pressure offset (3 psi to 5 only) (1) – – ±1 mV
Full-scale span(2)
Standard output–current excitation 75 – 150 mV
Standard output–voltage excitation 40 – 120 mV
Normalized output–current excitation 98 – 102 mV
Normalized output–current excitation (3 psi only) 73 – 77 mV
Normalized output–voltage excitation 38 – 42 mV
Pressure non-linearity(3) – ±0.15 ±0.20 %FSS
Pressure hysteresis(3) – – ±0.0125 %FSS
Repeatability – – ±0.0125 %FSS
Temperature effect on offset(4) – – ±0.5 mV
Temperature effect on offset (3 psi and 5 psi only) (4) – – ±1 mV
Temperature effect on span – – ±0.5 mV
Temperature effect on span (3 psi and 5 psi only) (4) – ±1 mV
Thermal hysteresis – ±0.1 – %FSS
Response time(5) – – 1 ms
Long term stability of offset and span(6) – – ±0.2 %FSS
Common mode voltage(7)
Standard output–current excitation – 50 % – input
Standard output–voltage excitation – 50 % – input
Normalized output–current excitation – 35 % – input
Normalized output–voltage excitation – 25 % – input
Input resistance – – – –
Current excitation 2.0 – 8.0 kΩ
Voltage excitation 8.0 – 40 kΩ
Output resistance 3.5 – 6.0 kΩ
PRESSURE RANGE SPECIFICATIONS
Catalog Listing Pressure Range Top Side Overpressure(8) Bottom Side Overpressure(9)
1805-00 (G,D) - (K,L) (0..4) (M,L,N) 0 psi to 3 psi 15 psi 9 psi
1805-01 (G,D) - (K,L) (0..4) (M,L,N) 0 psi to 5 psi 25 psi 15 psi
1800-02 (G,D) - (K,L) (0..4) (M,L,N) 0 psi to 10 psi 50 psi 30 psi
1800-03 (G,D) - (K,L) (0..4) (M,L,N) 0 psi to 15 psi 65 psi 45 psi
1800-07 (G,D) - (K,L) (0..4) (M,L,N) 0 psi to 30 psi 250 psi 50 psi
1800-08 (G,D) - (K,L) (0..4) (M,L,N) 0 psi to 50 psi 350 psi 50 psi
1800-09 (G,D) - (K,L) (0..4) (M,L,N) 0 psi to 100 psi 350 psi 50 psi
1800-10 (G,D) - (K,L) (0..4) (M,L,N) 0 psi to 150 psi 350 psi 50 psi
Notes:
1. Reference conditions (unless otherwise noted); TA = 25 °C [77 °F], Supply VS = 10 Vdc ±0.01 Vdc or IS = 1.5 mA ±0.0015 mA.
2. Full-scale span (FSS) is the algebraic difference between the output voltage at full-scale pressure and the output at zero pressure. FFS is
ratiometric to the supply voltage.
3. Pressure non-linearity is based on best-fit straight line from the zero to the full-scale pressure. Pressure hysteresis is the maximum output
difference at any point within the operating pressure range for increasing and decreasing pressure.
4. Maximum error band of the offset voltage or span over the compensated temperature range, relative to the 25 °C [77 °F] reading.
5. Response time for a 0 psi to full-scale span pressure step change, 10 % to 90 % rise time.
6. Long term stability over a six month period.
7. Common mode voltage as measured from output to ground. For higher levels of common mode voltage, contact the factory.
8. Pressure overrange: Top: 5 x full-scale pressure or ≤350 psi, whichever is less.
9. Pressure overrange: Bottom: 3 x full-scale or ≤50 psi, whichever is less.