General Specifications
Item
Input 115/230VAC ± 10%, 47 - 440Hz (derate output current 15% @ 400Hz)
Output Floating, adjustable w/ multi-turn cermet pots over range per table
Line Regulation ± 0.05% for 10% line change (0.2% for 20% change)
Load Regulation ± 0.05% for 50% load change (0.2% for 100% change)
Transient Response <50µs for 50% load change
Noise and Ripple 0.1% peak-to-peak
Stability ± 0.1% max for 24 hrs after warmup
Temp. Coefficient ± 0.01%/˚C max.
Operating Temp. 0 - 55˚C; Dereate 2%/˚C to 71˚C
0 to 55˚C Operating Temperature w/o Derating
Electrostatically Shielded Transformer
Remote Sensing
Physical Specifications
Dimensions (cm): 15.88 X 13.34 X 12.37
(6.25” X 5.25” X 4.87”)
Weight: 4.10kg (9.1 lbs.)
Output Specifications*
Model Output Rating Output Current
(Vdc) (A)
XE60-5 5 12.0
6 10.0
XE60-12 11 8.4
12 8.0
13 7.4
XE60-15 14 7.0
15 6.6
16 6.0
XE60-24 20 4.8
21 4.8
22 4.4
23 4.4
24 4.0
25 4.0
* Other voltage/current combinations are available in OEM quantities
TAIYO YUDEN
XE60
Model
Extended Performance
Single-Output Power Supplies
XE60
Model
Certifications
UL 478
Optional Overvoltage
Protection (OVP) Specfications
Voltage: Adjustable with sealed cermet pot
Overvoltage Trip Margin: Set at 120% nominal
Stability: ±0.1%/˚C max.
±0.1%/24 hrs. after warmup
Temperature Coefficient: 0.01%/ºC max.
Response Time: 8µsec typical
Speed: Controlled; no nuisance tripping
.92
.213 DIA.
.25
6.25
5.75
.94
2.75
5.25
VOLTAGE AND OVP ADJ. POTS
DC OUTOUT TERMINALS
( 8 – 32 STUDS )
––S+S+
4 HOLES
4.31
10-32 THREAD
2 PLACES .27
4.87
AC INPUT TERMINALS
230V
115V
1234
LINE
LINE
© Copyright 2001 Taiyo Yuden (U.S.A.), Inc. Specifications subject to change without notice.
Taiyo Yuden (U.S.A.), Inc.
1770 LaCosta Meadows Drive, San Marcos, CA 92069
(760) 510-3200 / Fax: (760) 471-4021
(800) 493-6835
www.t-yuden.com powerproducts@t-yuden.com
world leaders in materials and electronics technology
FM 32227