SCHURTER AG CH-6002 Luzern www.schurter.com Data sheet 4740 Stripbloc CONTENT 1 GENERAL DESCRIPTION .......................................................................................................... 2 2 DIMENSIONS .............................................................................................................................. 3 3 ELECTRICAL DATA ................................................................................................................... 5 3.1 3.2 3.3 3.4 3.5 3.6 3.7 3.8 3.9 3.10 3.11 4 GENERAL .............................................................................................................................. 5 GENERAL FOR FILTER TYPE .................................................................................................... 5 CABLE WITH PLUG ................................................................................................................. 6 APPLIANCE INLET................................................................................................................... 6 APPLIANCE OUTLET ............................................................................................................... 6 ROCKER-SWITCH ................................................................................................................... 6 FUSEHOLDER ........................................................................................................................ 7 NEON INDICATOR................................................................................................................... 7 MAINS-FILTER ....................................................................................................................... 7 DIAGRAMS ............................................................................................................................ 8 COMPONENTS DATA FOR FILTER TYPE..................................................................................... 9 MECHANICAL DATA .................................................................................................................. 9 4.1 4.2 MOUNTING ............................................................................................................................ 9 PACKING AND WEIGHT............................................................................................................ 9 5 MATERIALS .............................................................................................................................. 10 6 ENVIRONMENTAL CONDITION ............................................................................................... 11 6.1 TEMPERATURES .................................................................................................................. 11 7 APPROVALS............................................................................................................................. 12 8 ORDER CODE........................................................................................................................... 13 Page 1 of 13 Created date: 11/29/2003 11:26:00 AM Created by: HU Released date: 4/7/2008 Released by: HU Notification-No. 19600 Document-No. 0105.1835 Index b Print date: 07/04/2008 11:40:00 SCHURTER AG CH-6002 Luzern www.schurter.com 1 GENERAL DESCRIPT ION General The 4740 / 4760 series Stripbloc are stand alone Distribution Units, available as class I, made for pin temperature max. 70C, L and N shuttered. The Stripbloc is designed to enable up to 6 low power appliances to be connected simultaneously. Variations of distribution units type 4740/4760: - All versions available with IEC-inlet or country specific cables. - Distribution unit with 6 outlets. - Distribution unit with 5 outlets, fuseholder and neon. - Distribution unit with 5 outlets and rocker-switch illuminated. - Distribution unit with 5 outlets, fuseholder, neon and filter. The Stripbloc type 4740 / 4760 consists of the following parts and meets the appropriate standards: Cable with plug All cables are approved to the country specific requirements and standards - BS 1363A British plug with cable type H05VV-F3G x 1.0mm2. - CEE 7/VII European Schuko plug with cable type H05VV-F3G x 1.0mm2. - IEC / EN 60320-2-2/E IEC Coupler with cable type H05VV-F3G x 1.0mm2. - NEMA 5-15 North America NEMA 5-15 plug with cable type SVT 3 x 18AWG. Appliance Inlet The appliance inlet meets the following standards: - IEC / EN 60320-1 Standard sheet C14 - UL 498 - CSA 22.2 No 42 Protection class I ( L / N / PE ) to IEC 61140. Appliance outlet The appliance outlet meets the following standards: - IEC / EN 60320-2-2 Standard sheet F - UL 498 Protection class I ( L / N / PE ) to IEC 61140. Fuseholder The fuseholder meets the following standards: - IEC / EN 60127-6 - UL 512 - CSA C22.2-39 The live parts cannot be touched with the standard test-finger according to IEC 60529 in the following conditions: - during operating, i.e. with inserted fuse-drawer. - during opening, i.e. with open fuse-drawer. - during replacing the fuse-link held by the fuse-drawer. Page 2 of 13 Created date: 11/29/2003 11:26:00 AM Created by: HU Released date: 4/7/2008 Released by: HU Notification-No. 19600 Document-No. 0105.1835 Index b Print date: 07/04/2008 11:40:00 SCHURTER AG CH-6002 Luzern www.schurter.com Neon The neon indicator meets the following standards: VDE 0710 Part 1+11 Rocker switch The rocker-switch meets the following standards: - IEC / EN 61058-1 Mains-filter 1-stage mains-filter for standard application. The mains-filter meets the following standards: - IEC / EN 60939 - UL 1283 - CSA 22.2 No.8 2 DIMENSIONS Type 4740 with 6 outlets. Page 3 of 13 Created date: 11/29/2003 11:26:00 AM Created by: HU Released date: 4/7/2008 Released by: HU Notification-No. 19600 Document-No. 0105.1835 Index b Print date: 07/04/2008 11:40:00 SCHURTER AG CH-6002 Luzern www.schurter.com Type 4740 with 5 outlets, fuseholder and neon. Type 4740 with 5 outlets and rocker-switch illuminated. Type 4740 with 5 outlets fuseholder, neon and filter Page 4 of 13 Created date: 11/29/2003 11:26:00 AM Created by: HU Released date: 4/7/2008 Released by: HU Notification-No. 19600 Document-No. 0105.1835 Index b Print date: 07/04/2008 11:40:00 SCHURTER AG CH-6002 Luzern www.schurter.com 3 ELECTRICAL DAT A 3.1 General Rated voltage Un 125 / 250 VAC Rated current In 10 A Insulation resistance (500 V DC ; 1 min.) > 5 M between live parts of different potentials. (without neon) between protective conductor PE and live parts. > 5 M Dielectric strength (50 Hz ; 1 min.) 50 / 60 Hz > 2.5 kV between live parts of different potentials. (without neon) between protective conductor PE and live parts. > 2.5 kV Maximal internal earth link Resistance 0.25 Overvoltage category I - III according to IEC 60664-1 Clearence and creepage distances > 3 mm > 4 mm between live parts of different potentials. between protective conductor PE and live parts. Pollution degree 1- 3 according to IEC 60664-1 Protection class (Protection against electric shock) Suitable for appliances of protection class I acc. to IEC 61140 respectively acc. to VDE 0106 / part 1 3.2 General for filter type Rated voltage Un 125 / 250 VAC Rated current In 6A Insulation resistance (500 V DC ; 1 min.) > 5 M > 5 M Dielectric strength (DC ; 1 min.) > 1.7 kV Test voltage (2sec.) Fabrication test Page 5 of 13 Created date: 11/29/2003 11:26:00 AM 50 / 60 Hz Created by: HU between live parts of different potentials. (without bleed resistor) between protective conductor PE and live parts. > 2.7 kV between live parts of different potentials. (without bleed resistor) between protective conductor PE and live parts. 1075 V DC 1500 V AC between live parts of different potentials. between protective conductor PE and live parts. Released date: 4/7/2008 Released by: HU Notification-No. 19600 Document-No. 0105.1835 Index b Print date: 07/04/2008 11:40:00 SCHURTER AG CH-6002 Luzern www.schurter.com 3.3 Cable with plug Cord sets with adjusted cable length and stripped end. Protection class I, pin temperature max. 70C (cold condition) United Kingdom (British Plug) Cord Type: Rated H05VV-F3G1.0 10 A / 250VAC Continental Europe (SCHUKO) Cord Type: Rated H05VV-F3G1.0 10 A / 250VAC IEC Coupler (EN 60320) Cord Type: Rated H05VV-F3G1.0 10 A / 250VAC North America (NEMA) Cord Type: Rated SVT 10 A / 125VAC 3.4 Appliance inlet Appliance inlet, Snap-in mounted Rated voltage Un Rated current In Pin temperature Type designation 250 VAC 10 A 15 A max. 70 C 61XX 3.5 Appliance outlet Appliance outlet, flanged, L / N shuttered Rated voltage Un 250 VAC Rated current In 10 A 15 A Made for pin temperature max. 70 C Type designation 4721 50 / 60 Hz VDE UL / CSA 50 / 60 Hz VDE UL 3.6 Rocker-switch 2-poles illuminated (red) ON- / OFF-switch. Rated voltage Un 250 VAC 50 / 60 Hz Rated current In 16 (4) A Inrush capability 150 A to IEC 65 Insulation resistance > 20 M Delectric strength: across open contacts > 1 kV (AC) between poles > 3 kV (AC) Contact gap > 3 mm Manufacturer Arcolectric Switches plc, 61 Central Avenue, West Molesey Surrey, England KT8 Type designation C 1353 VT (2-pol) illuminated Page 6 of 13 Created date: 11/29/2003 11:26:00 AM Created by: HU Released date: 4/7/2008 Released by: HU Notification-No. 19600 Document-No. 0105.1835 Index b Print date: 07/04/2008 11:40:00 SCHURTER AG CH-6002 Luzern www.schurter.com 3.7 Fuseholder Fuseholder 1-pole for fuse links 5 x 20mm with bayonet type fuse carrier, slotted. The fuse holder is accessible from the equipment front. Rated voltage Un 250 VAC 50 / 60 Hz Rated current In 10 A VDE Rated Power Acceptance 4 W / 10 A @ Ta 23 C Contact resistance 5 m Dielectric strength (50 Hz ; 1 min.) > 4kV Insulation resistance (500 V DC ; 1 min.) > 103 M Type designation FEF 3.8 Neon indicator Rated voltage Un Rated current In Manufacturer Type designation 250 VAC 50 / 60 Hz 10 A Signal Lux CH-6900 Lugano Switzerland Series 24.5 illuminated red 3.9 Mains-filter Rated voltage Un Rated current In 125 / 250 V AC 50 / 60 Hz 6A @ Ta 40 C ; according to IEC / EN, UL, CSA Max. leakage current mains-filter standard The mains-filter for standard applications meets IEC / EN 60393 / UL 1283 / CSA C22.2 no.8 Page 7 of 13 Created date: 11/29/2003 11:26:00 AM Created by: HU Released date: 4/7/2008 Released by: HU max. 1.0 mA (250V / 60Hz) Notification-No. 19600 Document-No. 0105.1835 Index b Print date: 07/04/2008 11:40:00 SCHURTER AG CH-6002 Luzern www.schurter.com 3.10 Diagrams All Inputs are: Inlet or Cable Distribution unit with 6 outlets. - Distribution unit with 5 outlets, fuseholder and neon. - Distribution unit with 5 outlets and rocker-switch illuminated. - Distribution unit with 5 outlets fuseholder, neon and filter. Page 8 of 13 Created date: 11/29/2003 11:26:00 AM Created by: HU Released date: 4/7/2008 Released by: HU Notification-No. 19600 Document-No. 0105.1835 Index b Print date: 07/04/2008 11:40:00 SCHURTER AG CH-6002 Luzern www.schurter.com 3.11 Components data for filter type Rated current [A] Filter type Inductors L1 / L2 [mH] Cx [nF] Cy [pF] R [M] 6 Standard 0.2 47 / 100 2x 4700 1 4 MECHANICAL DAT A 4.1 Mounting The distribution unit type 4740 / 4760 is a stand alone module. Fixing can be made with four screws. (see dimension drawing) Withdrawal Force When outlet is used with a suitable plug or connector 10 - 50N Features Shuttered outlets have mechanical covers over the L & N contacts which slide aside, like a camera shutter, when a plug is inserted into the outlet. The shutters spring back to cover the contacts when the plug is removed. This offers protection against electrical shock and ingress of dust into outlet when a plug is not inserted. See section `A' diagrams. 4.2 Packing and weight Original packing Page 9 of 13 Created date: 11/29/2003 11:26:00 AM 10 pcs. Created by: HU Released date: 4/7/2008 Released by: HU Notification-No. 19600 Document-No. 0105.1835 Index b Print date: 07/04/2008 11:40:00 SCHURTER AG CH-6002 Luzern www.schurter.com 5 MATERIALS Stripbloc case: ABS thermoplastic UL94 V-0 (1.5mm thick) Temp.-index RTI, electr.: 60C UL File-no.: E 50263 (S) Outlet: PPO thermoplastic UL94 V-0 (1.5mm thick) Live parts: Brass, tin-plated Shutters: PA6 Thermoplastic UL94 -0 (1mm thick) Shutter spring: Galvanised steel Inlet: PA6 thermoplastic UL94 V-0 Live parts: Brass, tin-plated / nickel-plated Cable: PVC Live parts (wire link): Copper alloy, protected against corrosion. Rocker switch: Nylon 6.6, Polycarbonate, UL94 V-2 Copper alloy, silver-plated, silver alloy Screws Steel nickel-plated, steel hardened zinc-plated Cable Clamp Steel zinc-plated & PA66 Insulating sleeves PVC, Flex. Polyolefin Page 10 of 13 Created date: 11/29/2003 11:26:00 AM Created by: HU Released date: 4/7/2008 Released by: HU Notification-No. 19600 Document-No. 0105.1835 Index b Print date: 07/04/2008 11:40:00 SCHURTER AG CH-6002 Luzern www.schurter.com 6 ENVIRONMENTAL CONDITION 6.1 Temperatures Storage temperature: - 40C up to + 85C Operating temperature: - 25C up to + 70C Climatic category: 25 / 085 / 21 according to IEC 60068-1 Derating curve : Fuse-holder Table 1 : Admissible power acceptance versus ambient air temperature Ta Remark The admissible power acceptance of the fuseholder is determined by a standardized testing procedure at rated current and at an ambient air temperature of 23 C, whereby the maximum permissible temperatures at the fuseholder must not be exceeded. Application and mounting method, especially for closed fuseholder, can influence the heating situation considerably. Therefore the heating situation has to be tested at the working condition of the fuseholder at maximum current and maximum ambient air temperature. Page 11 of 13 Created date: 11/29/2003 11:26:00 AM Created by: HU Released date: 4/7/2008 Released by: HU Notification-No. 19600 Document-No. 0105.1835 Index b Print date: 07/04/2008 11:40:00 SCHURTER AG CH-6002 Luzern www.schurter.com 7 APPROVALS The Stripblic individual parts meets the following approvals: (Outlet, Inlet, Fuseholder, Neon, Rocker-switch) ENEC UL CSA / cUL VDE Inlet 6100.4120 E 96454 Vol.1 Sec.6 LR 38456 3479 UG - Outlet 4721.0300 E 69454 Vol.1 Sec.17 E 69454 Vol.1 Sec.17 40001632 - Fuse holder 0031.1081 (FEF) E 39328 Vol.1 Sec.24 LR 38456 131952 UG - E 63686 Vol.1 Sec.1 E 63686 Vol.1 Sec.1 022844 - E 45221 LR 10990 - 55008702 Neon 0925.4000 Rocker Switch 0041.7500 (Demko) (Arcolectric C1353 VT) Cable with Plug Others British 6044.0204 - - - Mayor MP5004 Europe SCHUKO 6003.0215 (SL-9) - - - Demko 306040 IEC Coupler 6007.0214 (SL-4) - - 83495 - N. America NEMA 6009.1204 E 183417 E 183417 - - Page 12 of 13 Created date: 11/29/2003 11:26:00 AM Created by: HU Released date: 4/7/2008 Released by: HU Notification-No. 19600 Document-No. 0105.1835 Index b Print date: 07/04/2008 11:40:00 SCHURTER AG CH-6002 Luzern www.schurter.com 8 ORDER CODE 47X0 . X X X X . XX On customer request Reserved 0 - 9 = Reserved Reserved 0 - 9 = Reserved Input Type 0 = Inlet 1 = Inlet & Filter 6A 2 = Reserved 3 = Cable (2m) & British Plug 4 = Reserved 5 = Reserved 6 = Cable (2m) & SCHUKO Plug 7 = Cable (2m) & NEMA Plug 8 = Cable (2m) & EN 60320 Plug 9 = Cable (3m) stripped ends 1) 1) 1) 1) 1) Configuration 0 = Reserved 1 = 3 Outlets shuttered, 3 Fuseholders, 3 Neon 2 = Reserved 3 = 5 Outlets shuttered, Fuseholder, Neon 4 = 6 Outlets shuttered 5 = Reserved 6 = 5 Outlets shuttered, 1 Rocker-switch 7 - 9 = Reserved Product Type 4 = Stripbloc 6 = Stripbloc Arrow 1) Other cable length available on request Page 13 of 13 Created date: 11/29/2003 11:26:00 AM Created by: HU Released date: 4/7/2008 Released by: HU Notification-No. 19600 Document-No. 0105.1835 Index b Print date: 07/04/2008 11:40:00