SPECIFICATION CONTROL DRAWING 44A112X Date TWO CONDUCTOR CABLE, SHIELDED, JACKETED, 1-9-06 GENERAL PURPOSE, 600 VOLT This specification sheet forms a part of the latest issue of Raychem Specification 44. TITLE SHIELD - COPPER, COATING SAME AS ON CONDUCTOR EXCEPT TIN-COATED SHIELD WITH SILVERCOATED HIGH-STRENGTH ALLOY CONDUCTOR Revision G JACKET - RADIATION-CROSSLINKED, MODIFIED PVF2 COMPONENT WIRE - 44A011X TABLE I. CABLE CONSTRUCTION DETAILS PART NUMBER 1/ CONDUCTOR SIZE (AWG) SHIELD SIZE (AWG) 44A112X-26-* 44A112X-24-* 44A112X-22-* 44A112X-20-* 44A112X-18-* 44A112X-16-* 44A112X-14-* 44A112X-12-* 44A112X-10-* 26 24 22 20 18 16 14 12 10 38 36 36 36 36 36 36 36 36 PART NUMBER 1/ 44A112X-26-* 44A112X-24-* 44A112X-22-* 44A112X-20-* 44A112X-18-* 44A112X-16-* 44A112X-14-* 44A112X-12-* 44A112X-10-* JACKET THICKNESS (in.) MINIMUM .006 .006 .006 .006 .007 .007 .007 .007 .008 OUTSIDE DIAMETER (in.) NOMINAL .008 .008 .008 .008 .009 .009 .009 .009 .010 NOMINAL .102 .118 .132 .148 .170 .184 .218 .256 .299 TABLE II. CABLE PERFORMANCE DETAILS BEND TESTING MANDREL DIAMETER (inch) ( 3%) LIFE CYCLE, IMMERSION AND ACCELERATED AGING COLD BEND 3.00 3.00 6.00 6.00 6.00 6.00 6.00 10.0 10.0 3.00 3.00 6.00 6.00 6.00 6.00 6.00 10.0 10.0 MAXIMUM .107 .123 .137 .153 .175 .189 .225 .265 .314 MAXIMUM WEIGHT (lb/1000 ft) 8.1 11.3 14.5 18.8 25.7 30.2 43.2 61.5 86.3 WEIGHT (lb) ( 3%) LIFE CYCLE, IMMERSION AND ACCELERATED AGING .250 .375 .375 .375 .500 .500 1.00 1.00 1.00 COLD BEND 1.50 1.50 3.00 3.00 3.00 3.00 9.00 9.00 9.00 NOTE: Nominal values are for information only. Nominal values are not requirements. Users should evaluate the suitability of this product for their application. Specifications are subject to change without notice. Tyco Electronics also reserves the right to make changes in materials or processing, which do not affect compliance with any specification, without notification to Buyer. 1/ COLORS AND COLOR CODE DESIGNATORS SHALL BE IN ACCORDANCE WITH MIL-STD-681. HOWEVER, DUE TO LENGTH LIMITATIONS OF THE RAYCHEM PART NUMBER, AN ALTERNATIVE COLOR CODE MAY REPLACE MIL-STD-681 COLOR CODE DESIGNATORS. (EXAMPLE: "901/902..." MAY BE REPLACED BY "Axxx".) OTHER CODES AND SUFFIXES MAY BE ADDED TO THE PART NUMBER, AS NECESSARY, TO CAPTURE ANY ADDITIONAL REQUIREMENTS IMPOSED BY THE PURCHASE ORDER. DIMENSIONS ARE IN INCHES, AND UNLESS OTHERWISE DESIGNATED ARE NOMINAL. Page 1 of 2 THIS SPECIFICATION SHEET TAKES PRECEDENCE OVER DOCUMENTS REFERENCED HEREIN. REFERENCED DOCUMENTS SHALL BE OF THE ISSUE IN EFFECT ON DATE OF INVITATION FOR BID. R Wire & Cable 501 Oakside Avenue Redwood City, CA 94063-3800 Phone: 1-800-227-8816 Fax: 1-650-361-6297 (c) 2006 Tyco Electronics Corporation. All rights reserved. Revision SPECIFICATION CONTROL DRAWING Page 2 of 2 SCD Number G 44A112X CABLE RATINGS AND ADDITIONAL REQUIREMENTS TEMPERATURE RATING: 150C Maximum continuous conductor temperature VOLTAGE RATING: 600 volts (rms) at sea level ACCELERATED AGING: 300 3C for 6 hours BLOCKING: 150 3C for 6 hours DIELECTRIC WITHSTAND: 2500 volts (rms), 60 Hz, 1 minute FLAMMABILITY: 30 seconds (maximum); 3 in. (maximum); no flaming of facial tissue IMMERSION: Diameter increase 5% (maximum); no cracking, no dielectric breakdown JACKET COLOR: White preferred JACKET CONCENTRICITY: 70% (minimum) JACKET ELONGATION AND TENSILE STRENGTH: Elongation, 200% (minimum) Tensile Strength, 4000 lbf/in (minimum) JACKET FLAWS: Spark Test, 1.5 kV (rms) Impulse Dielectric Test, 6.0 kV (peak) LIFE CYCLE: 200 3C for 168 hours LOW TEMPERATURE-COLD BEND: -65 2C for 4 hours SHIELD COVERAGE: 85% (minimum) VOLTAGE WITHSTAND TEST (Post Environmental) : 1000 volts (rms), 60 Hz, 1 minute PART NUMBER: The "X" in the part numbers on page 1 shall be replaced by the applicable conductor material designator as follows: 1 tin-coated copper 2 silver-coated copper 3 nickel-coated copper 4 silver-coated high strength copper alloy (AWG's 26-16 only) 6 nickel-coated high strength copper alloy (AWG's 26-20 only) The "*" in the part numbers on page 1 shall be replaced by color code designators with a slash separating component wire colors and a dash separating the component wire color from the jacket color. 1/ Example: AWG 20, tin-coated copper, black and white component wires; white jacket: 44A1121-20-0/9-9 1/ see footer section on page 1