DC/DC Converter * * TIM 2 Series, 2 Watt Compact DIP-16-package I/O isolation 5000 VACrms rated for 250 VACrms working voltage * Certification according to IEC/EN/ES 60601-1 3rd edition for 2xMOPP and opperation to 5000 m altitude * Low leakage current < 2 A for BF-applications * Extended operating temperature range The TIM 2 series is a range of 2 Watt DC/DC converters in compact DIP-16 -40C to 95C. package and with reinforced isolation of 5000 VACrms for medical applications. * * EMC compliance to IEC 60601-1-2 4th With a low leakage current of less than 2 A the converters are predestined to edition and EN55032 class A insulate electrical equipment from the applied parts to patient (BF classification). 5-year product warranty The models are approved to IEC/EN/ES 60601-1 3rd edition for 2xMOPP up to an altitude of 5000m and come along with an ISO 14971 risk management file. Models Order code TIM 2-0910 TIM 2-0911 TIM 2-0919 TIM 2-0912 TIM 2-0913 TIM 2-0915 TIM 2-0922 TIM 2-0923 TIM 2-1210 TIM 2-1211 TIM 2-1219 TIM 2-1212 TIM 2-1213 TIM 2-1215 TIM 2-1222 TIM 2-1223 TIM 2-2410 TIM 2-2411 TIM 2-2419 TIM 2-2412 TIM 2-2413 TIM 2-2415 TIM 2-2422 TIM 2-2423 TIM 2-4810 TIM 2-4811 TIM 2-4819 TIM 2-4812 TIM 2-4813 TIM 2-4815 TIM 2-4822 TIM 2-4823 www.tracopower.com Input voltage range 4.5 - 12 VDC (9 VDC nominal) 9.0 - 18 VDC (12 VDC nominal) 18 - 36 VDC (24 VDC nominal) 36 - 75 VDC (48 VDC nominal) Output voltage 3.3 VDC 5.0 VDC 9.0 VDC 12 VDC 15 VDC 24 VDC 12 VDC 15 VDC 3.3 VDC 5.0 VDC 9.0 VDC 12 VDC 15 VDC 24 VDC 12 VDC 15 VDC 3.3 VDC 5.0 VDC 9.0 VDC 12 VDC 15 VDC 24 VDC 12 VDC 15 VDC 3.3 VDC 5.0 VDC 9.0 VDC 12 VDC 15 VDC 24 VDC 12 VDC 15 VDC Output current max. 500 mA 400 mA 222 mA 167 mA 134 mA 83 mA 83 mA 67 mA 500 mA 400 mA 222 mA 167 mA 134 mA 83 mA 83 mA 67 mA 500 mA 400 mA 222 mA 167 mA 134 mA 83 mA 83 mA 67 mA 500 mA 400 mA 222 mA 167 mA 134 mA 83 mA 83 mA 67 mA Efficiency typ. 74 % 78 % 79 % 81 % 81 % 81 % 81 % 81 % 75 % 78 % 78 % 81 % 81 % 81 % 81 % 82 % 75 % 78 % 78 % 80 % 81 % 81 % 81 % 82 % 75 % 77 % 78 % 80 % 81 % 81 % 81 % 81 % Page 1 of 4 TIM 2 Series, 2 Watt Input Specifications Input current no load 9 Vin models: 12 Vin models: 24 Vin models: 48 Vin models: 90 mA typ. 45 mA typ. 25 mA typ. 12 mA typ. Surge voltage (1 s max.) 9 Vin models: 12 Vin models: 24 Vin models: 48 Vin models: 15 V max. 25 V max. 50 V max. 100 V max. Start-up voltage 9 Vin models: 12 Vin models: 24 Vin models: 48 Vin models: 4.5 VDC (or lower) 9.0 VDC (or lower) 18 VDC (or lower) 36 VDC (or lower) Startup time 10 ms typ. / 20 ms max. Under voltage shut down 9 Vin models: 12 Vin models: 24 Vin models: 48 Vin models: 2 - 4 VDC 6 - 8 VDC 13 - 17 VDC 29 - 35 VDC Input filter capacitor type Conducted noise - Conducted & Radiated input suppression EN 55011 limits to IEC/EN 60601-1-2 4th edit. EN 55032 class A or B with external components - Application note for filter class A/B proposal www.tracopower.com/overview/tim2 EMC immunity - Generic for Medical equipment IEC/EN 60601-1-2 4th edition - ESD (electrostatic discharge) EN 61000-4-2, air 15 kV, contact 8 kV, perf. criteria A - Radiated immunity EN 61000-4-3, 10 V/m, perf. criteria A - Fast transient / surge EN 61000-4-4, 2 kV, perf. criteria A (with external input capacitor / diode) EN 61000-4-5, 1 kV perf. criteria A 9 Vin models: Nippon chemi-con KY 1000 F / 25 V TVS - SMAJ18A, 18 V, 400 W 12 & 24 Vin models: Nippon chemi-con KY 470 F / 50 V 48 Vin models: Nippon chemi-con KY 220 F / 100 V - Conducted immunity EN 61000-4-6, 10 Vrms, perf. criteria A - Magnetic field immunity EN 61000-4-8 100 A/m, continuous, perf. criteria A 1000 A/m, 1 sec., perf. criteria A External input fuse required 9 Vin models: 12 Vin models: 24 Vin models: 48 Vin models: 1.0 A (slow blow) 0.5 A (slow blow) 0.315 A (slow blow) 0.16 A (slow blow) Output Specifications Voltage set accuracy 1 % max. Regulation - Input variation (Vin min. to Vin max.) - Load variation (0 - 100 %) - Load variation (10 - 90 %) single output: dual output: - Cross regulation dual output: 0.2 % max. 1 % max. 0.5 % max. 0.8 % max. 5.0 % max. (asymmetrical load 25 / 100 %) Minimum load not required Ripple and noise (20 MHz Bandwidth) 50 mVp-p typ. Transient response (25% load step change) - Recovery time 500 s typ. Short circuit protection Continuous, automatic recovery All specifications valid at nominal input voltage, full load and +25C after warm-up time unless otherwise stated. www.tracopower.com Page 2 of 4 TIM 2 Series, 2 Watt General Specifications Overvoltage protection 3.3 Vout models: 5.0 Vout models: 9.0 Vout models: 12 Vout models: 15 Vout models: 24 Vout models: Capacitive load - Single output - Dual output 3.3 & 5.0 Vout models: 9.0 Vout models: 12 Vout models: 15 Vout models: 24 Vout models: 12 Vout models: 15 Vout models: Temperature ranges 4 - 6.5 VDC 6 - 8 VDC 10 - 14 VDC 13 - 19 VDC 16 - 22 VDC 25 - 35 VDC 1`000 F max. 430 F max. 220 F max. 170 F max. 100 F max. 170 F max. (each output) 100 F max. (each output) - Operating (natural convection: 20 LFM, 0.1 m/s) -40C to +95C - Case temperature +105C max. - Storage temperature -55C to +125C Derating 6.7 %/K above 90C Humidity (non condensing) 5 % to 95 % rel H max. Isolation voltage (50 Hz, 60 s) 5000 VAC (reinforced insulation) Working voltage 250 VAC, 2 x MOPP Isolation capacitance 20 pF max. Clearance/creepage 8 mm min. Leakage current ( at 240 VAC, 60 Hz) 2 A max. Altitude during operation 5000 m max. Temperature coefficient 0.02 %/K max. Reliability, calculated MTBF (MIL-HDBK-217F at +25C, ground benign) 6`809`000 h Switching frequency 100 kHz min. (frequency modulated) Shock, vibration and thermal shock resistance according to MIL-STD-810F Remote On/Off - On: open circuit or high impedance - Off: 2 - 4 mA current applied via 1kOhm resistor - Off idle current: 2.5 mA typ. Safety standards/approvals - Medical equipment ANSI/AAMI ES60601-1:2005/(R)2012, IEC/EN60601-1 3rd edition - Certification documents www.tracopower.com/overview/tim2 Environmental compliance - Reach www.tracopower.com/info/reach-declaration.pdf - RoHS RoHS directive 2011/65/EU Physical Specifications Casing material non-conductive black plastic Base material non-conductive black plastic Potting material silicone (UL94 V-0) Package weight 7.0 g (0.24 oz) Soldering temperature 260C / 10 s max. All specifications valid at nominal input voltage, full load and +25C after warm-up time unless otherwise stated. www.tracopower.com Page 3 of 4 TIM 2 Series, 2 Watt Outline Dimensions 3.2 (0.13) 14.4 (0.57) 10.16 Standard Pinout (0.400) 16 Pin 1 2 7 8 9 10 16 1 10 7 9 8 2.1 (0.08) 2.54 (0.100) BOTTOM VIEW 15.24 (0.600) 24.3 (0.95) 2 Single -Vin (GND) On/Off NC NC +Vout -Vout +Vin (Vcc) Dual -Vin (GND) On/Off NC Common +Vout -Vout +Vin (Vcc) O 0.60 (0.0024) 3.8 (0.15) 10.2 (0.40) (c) Copyright 2018 Traco Electronic AG Dimensions in mm (inch) Tolerances 0.5 (0.02) Pin o 0.6 0.1 (0.024 0.004) Pin pitch tolerances 0.25 (0.01) Specifications can be changed without notice! Rev. July 26, 2018 www.tracopower.com Page 4 of 4