SERIES DUAL-FUSE CONNECTOR FILTERS SPECIFICATIONS INTRODUCTIONS 1. Maximum leakage current each line-to-ground @ 115VAC 60Hz: 0.25mA @ 250VAC 50Hz: 0.45mA 2. Hipot rating (one minute) line-to-ground: 2250VDC line-to-line: 1450VDC 3. Operating frequency: 50/60Hz 4. Rated voltage: 115/250VAC 1. Designed as a general purpose filter with a fuse holder providing effective EMI suppression for both common and differential mode noise. 2. All part numbers are UL recognized, CSA certified and VDE approved. 3. Bleeder resistor is added with suffix "-R". 4. With optional Y CAP. from 100pF ~ 4700pF. COMPONENTS SERIES DIMENSIONS Cy (pF) 3300 R( ) DELTA PART NO. 1M MINIMUM INSERTION LOSS IN dB COMMON MODE (L-G) IN 50 OHM SYSTEM CURRENT FREQUENCY-MHz RATING .15 .50 1.0 5.0 10 2A 29 38 40 42 43 4A 19 30 32 42 42 6A 13 22 26 38 42 DIFFERENTIAL MODE (L-L) IN 50 OHM SYSTEM 2A 5 19 28 48 51 4A 5 14 21 48 48 6A 5 12 15 40 46 30 41 39 38 L Cx EG3F 06BEEG3F EG3F 2.263 2.106 57.5 53.5 1.66 42.0 1.42 36.0 1.74 44.0 COMMON MODE COMMON MODE 06BEEG3F DIFF. MODE DIFF. MODE 80 dB 50 42 38 60 dB 20 dB Cy L O A D 0 dB N N' G G' 1.122 28.5 C MAX. Use only with a 250V fuse Employer uniquement avec un fusible de 250V MECHANICAL CONSTRUCTION 1M 100K 10K 10M SUGGESTED MOUNTING CUTOUT (MOUNTING FROM FRONT) B MAX. M3 BEEG3F 1.303 0.004 33.1 0.1 4-6 R0.14 R3.5 1.142 0.004 29.0 0.1 1.283 32.6 A MAX. UNIT: INCH mm POWER ENTRY MODULE FILTERS Cy F 04BEEG3F 04BEEG4F L' R EG3F DIMENSIONS IN INCHES/mm B C D E 40 dB L F 02BEEG3F A INSERTION LOSS (TYPICAL) ELECTRICAL SCHEMATIC L I N E STYLE D 0.1 L (mH) 4.0 1.8 0.8 E MAX. Cx (uF) 1.417 0.004 36.0 0.1 PART NO. 02BEEG3F/-R 04BEEG3F/-R 06BEEG3F/-R V D E