MtronPTI reserves the right to make changes to the product(s) and service(s) described herein without notice. No liability is assumed as a result of their use or application.
Parameter Symbol Min. Typ. Max. Units Conditions/Notes
Frequency Range F 50 1400 MHz LVPECL, LVDS, CML (Note 4)
50 135 MHz CMOS
Operating Temperature T
A
See Ordering Information °C
Storage Temperature T
STG
-55 +125 °C
Frequency Stability See Ordering Information ppm See Note 1
Frequency Tolerance at +25°C -1.0 +1.0 ppm
Frequency Vs. Aging -3.0
-1.0
+ 3.0
+ 1.0
ppm
ppm
1
st
year
Per year thereafter.
Frequency Vs. Supply Voltage ± 0.4 ppm 5% voltage variation
Frequency Vs. Reflow ±
0.75
ppm 2 reflows max.
Frequency Vs. Load ± 0.2 ppm 5% supply voltage variation
Operating Voltage V
cc
/V
s
/V
dd
3.135 3.3 3.465 V M6300
2.375 2.5 2.625 V M6301
1.71 1.8 1.89 V M6302
Operating Current I
CC
125 mA LVPECL
100 mA LVDS
110 mA CML
90 mA CMOS
Rise/Fall Time Tr/Tf 0.35 ns PECL, LVPECL, LVDS
6 ns CMOS
Logic “1” Level V
OH
V
CC
-1.02
90% V
dd
V
V
LVPECL
CMOS
Logic “0” Level V
OL
V
CC
-1.63
10% V
dd
V
V
LVPECL
CMOS
Common Mode Output Voltage Vcm 1.2 V LVDS
Symmetry (Duty Cycle) 45
45
45
55
55
55
%
%
%
@ 50% Vdd (CMOS)
@ 50% of waveform (LVPECL)
@ 1.25 V (LVDS)
Output Voltage Level 0.7 0.95 1.2 Vp-p CML
Tuning Range ± 5 ppm VCTCXO only. See Note 2.
Voltage Control Range 0.3 1.35 3.0 V VCTCXO. Pad 2 only.
Output Skew 20
15
20
ps
ps
ps
LVPECL
CML
LVDS
Output Load
50 to (V
CC
-2)
VDC 100
Differential
See Note 3
LVPECL
LVDS, CML
15 pF CMOS
Enable/Disable Function 80%
80%
0.5
0.5
V
V
Outputs enabled (Option B or G)
Outputs disabled
Outputs enabled (Option S or M)
Outputs disabled
Phase Noise (Typical) 10 Hz 100 Hz 1 kHz 10 kHz 100 kHz Offset from carrier
Electrical Specifications
@ 622.080 MHz (LVPECL)
@ 100.000 MHz (HCMOS)
@ 50.000 MHZ (HCMOS)
-60
-73
-80
-90
-97
-102
-120
-123
-130
-127
-131
-137
-133
-136
-141
dBc/Hz
dBc/Hz
dBc/Hz
Shock Per MIL-STD-202, Method 213, Condition C
Vibration Per MIL-STD-202, Methods 201 & 204
Solderability Per EIAJ-STD-002
Hermeticity 1 X 10
-8
atm cc/sec of helium (Crystal only)
Thermal Shock Per MIL-STD-883, Method 1011, Condition A
Environmental
Thermal Cycle Per MIL-STD-883, Method 1010, Condition B
Note 1: Contact factory for less than ± 1ppm frequency stability.
Note 2: Contact factory for other Tuning Range options.
Note 3: See Load Circuit Diagram in this data sheet.