Parameter Test Conditions Min. Typ. Max. Unit
nA
µA
nA
V
V
V
-
-
-
-
-
-
V
V
10
10
10
0.2
0.5
1.1
50
90
100 300
50
15
40
140
7
VCB = 90V
VCB = 90V Tamb = 150°C
VEB = 5V
IC= 150mA IB= 15mA
IC= 500mA IB= 50mA
IC= 150mA IB= 15mA
IC= 0.1mA
IC= 10mA
IC= 150mA
IC= 500mA
IC= 1A
IC= 150mA Tamb = -55°C
IC= 100µA
IE= 100µA
ICBO Collector – Base Cut-off Current
(IE= 0)
IEBO Emitter Cut-off Current (IC= 0)
VCE(sat)* Collector – Emitter Saturation Voltage
VBE(sat)* Base – Emitter Saturation Voltage
hFE* DC Current Gain (VCE = 10V)
V(BR)CBO Collector-base Breakdown Voltage
(IE= 0)
V(BR)EBO Emitter-base BreakdownVoltage
(IC= 0)
2N3700CSM
Parameter Test Conditions Min. Typ. Max. Unit
ELECTRICAL CHARACTERISTICS (Tcase = 25°C unless otherwise stated)
fTTransition Frequency
hfe Small Signal Current Gain
CEBO Emitter-base Capacitance
CCBO Collector-base Capacitance
rbb’Cb’cFeedback time constant
IC= 50mA VCE = 10V f = 20MHz
IC= 1mA VCE = 5V f = 1kHz
IC= 0 VEB = 0.5V f = 1MHz
IC= 0 VCB = 10V f = 1MHz
IC= 10mA VCB = 10V f = 4MHz
100
80 400
60
12
25 400
MHz
-
pF
pF
ps
* Pulse test tp = 300µs , δ ≤ 1%
DYNAMIC CHARACTERISTICS (Tcase = 25°C unless otherwise stated)
Semelab Plc reserves the right to change test conditions, parameter limits and package dimensions without notice. Information furnished by Semelab is
believed to be both accurate and reliable at the time of going to press. However Semelab assumes no responsibility for any errors or omissions discovered in
its use. Semelab encourages customers to verify that datasheets are current before placing orders.
Semelab plc. Telephone +44(0)1455 556565. Fax +44(0)1455 552612.
E-mail: sales@semelab.co.uk Website: http://www.semelab.co.uk Document Number 5594
Issue 1