High Freq
Frequency
[MHz]
Max. Insertion Loss
(Attenuation)
Min.
NEXT [dB]
Min.
PSNEXT [dB]
Min.
ACR [dB]
Min.
PSACR [dB]
Min. ACRF
(ELFEXT) [dB]
Min. PSACRF
(PSELFEXT) [dB]
Min. RL (Return
Loss) [dB]
Max./Min. Input
Impedance (unFitted)
Max./Min. Fitted
Impedance
1 MHz 2 dB/100m 65.3 dB 65.3 dB 63.3 dB 63.3 dB 63.8 dB 60.8 dB 20 dB 100 ± 12 Ohm 105 ± 10 Ohm
4 MHz 4 dB/100m 56.3 dB 56.3 dB 52.3 dB 52.3 dB 51.7 dB 48.7 dB 23 dB 100 ± 12 Ohm 100 ± 10
8 MHz 5.7 dB/100m 51.8 dB 51.8 dB 46.1 dB 46.1 dB 45.7 dB 42.7 dB 24.5 dB 100 ± 12 Ohm 100 ± 10
10 MHz 6.4 dB/100m 50.3 dB 50.3 dB 43.9 dB 43.9 dB 43.8 dB 40.8 dB 25 dB 100 ± 12 Ohm 100 ± 10
16 MHz 8.1 dB/100m 47.3 dB 47.3 dB 39.1 dB 39.1 dB 39.7 dB 36.7 dB 25 dB 100 ± 12 Ohm 100 ± 10
20 MHz 9.2 dB/100m 45.8 dB 45.8 dB 35.2 dB 35.2 dB 37.7 dB 34.7 dB 25 dB 100 ± 12 Ohm 100 ± 10
25 MHz 10.3 dB/100m 44.3 dB 44.3 dB 34.1 dB 34.1 dB 35.8 dB 32.8 dB 24.3 dB 100 ± 15 Ohm 100 ± 10
31.25 MHz 11.6 dB/100m 42.9 dB 42.9 dB 31.3 dB 31.3 dB 33.9 dB 30.9 dB 23.6 dB 100 ± 15 Ohm 100 ± 10
62.5 MHz 16.8 dB/100m 38.4 dB 38.4 dB 21.6 dB 21.6 dB 27.8 dB 24.8 dB 21.5 dB 100 ± 15 Ohm 100 ± 10
100 MHz 21.7 dB/100m 35.3 dB 35.3 dB 17.1 dB 17.1 dB 23.8 dB 20.8 dB 20.1 dB 100 ± 15 Ohm
155 MHz 27.7 dB/100m 32.5 dB 32.5 dB 4.7 dB 4.7 dB 19.9 dB 16.9 dB 19 dB 100 ± 18 Ohm
200 MHz 32 dB/100m 30.8 dB 30.8 dB 3 dB 3 dB 17.7 dB 14.7 dB 19 dB 100 ± 20 Ohm
250 MHz 36.4 dB/100m 29.3 dB 29.3 dB 0 dB 0 dB 15.8 dB 12.8 dB 18 dB 100 ± 20 Ohm
300 MHz 40.5 dB/100m 28.2 dB 28.2 dB 0 dB 0 dB 14.2 dB 11.2 dB 18 dB 100 ± 20 Ohm
310 MHz 41.3 dB/100m 27.9 dB 27.9 dB 13.9 dB 10.9 dB 18 dB 100 ± 20 Ohm
350 MHz 44.3 dB/100m 27.2 dB 27.2 dB 12.9 dB 9.9 dB 17 dB 100 ± 22 Ohm
Voltage
UL Voltage Rating Non-UL Voltage Rating
300 V (CM) 300 V (CMG-HL)
Mechanical Characteristics
Temperature
UL Rating. Operating Installation Storage
60°C -25°C To +75°C -25°C To +75°C -25°C To +85°C
Bend Radius
Stationary Min.
6.5 in
Max. Pull Tension: 40 lbs
Bulk Cable Weight: 101 lbs/1000ft
Standards and Compliance
Environmental Suitability: Indoor (Not Riser or Plenum), Indoor, Outdoor, Sunlight Resistance, Oil Resistance
Flammability / Fire Resistance: UL 1685 (UL Loading), FT4, FT4
NEC / UL Compliance: Article 800, CM
CEC / C(UL) Compliance: CMG, HL, CMG-HL
IEEE Compliance: IEEE 802.3bt Type 1, Type 2, Type 3
Data Category: Category 5e
European Directive Compliance: EU Directive 2015/863/EU, EU Directive 2011/65/EU (ROHS II), EU Directive 2012/19/EU (WEEE), REACH: 2020-01-16
APAC Compliance: China RoHS II (GB/T 26572-2011)
Part Number
Variants
Item # Color Putup Type Length UPC
121700A 0101000 Black Reel 1,000 ft 612825108962
121700A 0103000 Black Reel 3,000 ft 612825399728
121700A 0105000 Black Reel 5,000 ft 612825108979
121700A 0081000 Gray Reel 1,000 ft 612825108955
Product Notes
Notes: US Patent #'s 5606151; 5734126 Operating temperatures are subject to length de-rating. Cable passes -40C Cold Bend per UL 1581.
History
Update and Revision: Revision Number: 0.376 Revision Date: 03-16-2021