Material Compatibility
ABS Good
Buna-N Good
EPDM Poor
Graphite Excellent
HDPE Excellent
Kynar Fair
LDPE Fair
Lexan Fair
Neoprene Non-Compatible
Noryl Good
Nylon 66 Excellent
Cross-Linked PE Excellent
Polypropylene Good
Polystyrene Not recommended
PVC Good
Silicone Rubber Not recommended
Teflon Excellent
Viton Excellent
Performance
Product Required for Rosin Removal
(mg solvent used to remove 1 mg rosin flux)
Flux-Off Rosin 101
Conventional Flux Remover 3673
Rosin Removal Rate (mg / in2 sec.)
Flux-Off Rosin 4.0
Conventional Flux Remover 0.3
USAGE INSTRUCTIONS
For industrial use only.
Read MSDS carefully prior to use.
Spray 4-6” from surface to clean. Wash parts from
top to bottom, allowing the liquid to flush away dirt
and dissolved grease. For precise application use
attached extension tube. Product is Flammable - Do
not use near sources of ignition and energized
equipment.
TECHNICAL & APPLICATION
ASSISTANCE
ITW Chemtronics provides a technical hotline to
answer your technical and application related
questions. The toll free number is:
1-800-TECH-401.
AVAILABILITY
ES1035 10 oz. Aerosol
ES1035 10 oz. BrushClean Aerosol
ES835B 5 oz. BrushClean Aerosol
ES135 1 gallon Liquid
ES535 5 gallon Liquid
ES5535 53 gallon Liquid
ENVIRONMENTAL IMPACT DATA
HCFC-141b
HCFC-225 None
None HFC
nPB Aerosol -Yes
None
Hydrochlorofluorocarbons (HCFCs) are regulated under the Montreal Protocol
as Class II ozone depleting substances. HCFC-141b is no longer produced in the
US under this legislation. HCFC-225 is planned for production phase-out in
2015. Hydrofluorocarbons (HFCs) are not currently regulated.
EPA has listed n-propyl bromide (nPB) as an acceptable alternative to ozone
depleting substances in metal, precision, and electronics cleaning under Section
612 of the Clean Air Act.
NOTE: This information is believed to be accurate.
It is intended for professional end users having the
skills to evaluate and use the data properly. ITW
CHEMTRONICS does not guarantee the accuracy
of the data and assumes no liability in connection
with damages incurred while using it.
Chemtronics and Flux-Off are registered trademarks of
ITW Chemtronics. All rights reserved.
All other trademarks herein are trademarks or registered
trademarks of their respective owners.
MANUFACTURED BY:
ITW CHEMTRONICS
8125 COBB CENTER DRIVE
KENNESAW, GA 30152
1-770-424-4888 REV. B (06/09)
DISTRIBUTED BY: