APH-161-12-16-E Peltier cooler module Data sheet Imax Vmax Pc max Tmax A A1 B H L Wire [A] [Vdc] [W] [C] [mm] [mm] [mm] [mm] [mm] AWG 4.5 19.5 49.2 69 40 40 40 3.9 100 n/a (At hot side temperature Th = 25C / 298K, under dry N2 ). Pc max = Cooling power at T = 0 and I = Imax. Tmax = Temperature difference at I = Imax and Pc = 0. Max hot side temperature Th = 80C for best long term performance. Max mounting pressure: 1.5MPa. Wires: UL-style 1569, 105oC (Unstripped). Adaptive is a registered trademark of European Thermodynamics Limited. Web: www.etdyn.com Tel: +44(0)116 279 6899 E-mail: info@etdyn.com APH-161-12-16-E Peltier cooler module Data sheet - At hot side temperature 25C 60 I = 2.5 A 40 I = 2.0 A I = 1.5 A 30 I = 1.0 A 20 Waste heat (W) I = 3.5 A 50 Heat removed (W) 140 I = 4.5 A Max COP I = 4.5 A 120 I = 3.5 A 100 I = 2.5 A I = 2.0 A 80 I = 1.5 A 60 I = 1.0 A 40 10 20 0 0 0 20 40 60 80 0 20 Temperature difference (oC) 25 60 80 5.0 I = 4.5 A I = 3.5 A 20 I = 1.0 A 10 5 Delta T = 20 C 3.5 I = 2.0 A I = 1.5 A Delta T = 10 C 4.0 I = 2.5 A 15 Delta T = 0 C 4.5 Delta T = 30 C 3.0 COP Input Voltage (V) 40 Temperature difference (oC) Delta T = 40 C 2.5 2.0 Delta T = 50 C 1.5 Delta T = 60 C 1.0 0.5 0 0.0 0 20 40 60 Temperature difference (oC) Adaptive is a registered trademark of European Thermodynamics Limited. Web: www.etdyn.com Tel: +44(0)116 279 6899 E-mail: info@etdyn.com 80 0 1 2 3 Current (A) 4 5 APH-161-12-16-E Peltier cooler module Data sheet - At hot side temperature 50C 60 I = 2.0 A I = 1.5 A 30 I = 1.0 A 20 Waste heat (W) I = 2.5 A 40 I = 4.5 A 140 I = 3.5 A 50 Heat removed (W) 160 I = 4.5 A Max COP I = 3.5 A 120 I = 2.5 A 100 I = 2.0 A I = 1.5 A 80 I = 1.0 A 60 40 10 20 0 0 0 20 40 60 0 80 20 Temperature difference (oC) 30 60 80 5.0 I = 4.5 A I = 1.0 A 10 Delta T = 30 C 3.0 COP 15 Delta T = 20 C 3.5 I = 2.0 A I = 1.5 A Delta T = 10 C 4.0 I = 2.5 A 20 Delta T = 0 C 4.5 I = 3.5 A 25 Input Voltage (V) 40 Temperature difference (oC) Delta T = 40 C 2.5 2.0 Delta T = 50 C 1.5 Delta T = 60 C 1.0 5 0.5 0 0.0 0 20 40 60 80 Temperature difference (oC) Adaptive is a registered trademark of European Thermodynamics Limited. Web: www.etdyn.com Tel: +44(0)116 279 6899 E-mail: info@etdyn.com 0 1 2 3 Current (A) 4 5 APH-161-12-16-E Peltier cooler module Data sheet - At hot side temperature 75C 180 I = 4.5 A 60 I = 3.5 A 50 I = 2.5 A I = 2.0 A 40 I = 1.5 A 30 I = 1.0 A I = 3.5 A 140 I = 2.5 A 120 I = 2.0 A 100 I = 1.5 A 80 I = 1.0 A 60 Max COP 20 I = 4.5 A 160 Waste heat (W) Heat removed (W) 70 40 10 20 0 0 0 20 40 60 80 0 100 20 Temperature difference (oC) 30 60 80 100 6.0 I = 4.5 A I = 3.5 A 25 Delta T = 0 C Delta T = 10 C 5.0 I = 2.5 A 20 Delta T = 20 C 4.0 I = 2.0 A I = 1.5 A 15 I = 1.0 A COP Input Voltage (V) 40 Temperature difference (oC) Delta T = 40 C 3.0 Delta T = 50 C 10 2.0 5 1.0 0 Delta T = 30 C Delta T = 60 C 0.0 0 20 40 60 80 Temperature difference (oC) Adaptive is a registered trademark of European Thermodynamics Limited. Web: www.etdyn.com Tel: +44(0)116 279 6899 E-mail: info@etdyn.com 100 0 1 2 3 Current (A) 4 5