Revised: January 7, 2009
347
© 2009 Littelfuse, Inc.
Specifications are subject to change without notice.
Special Application Fuses
Alarm Indicating Fuseholder 482 Series
482 Series Alarm Indicating Fuse Holder
Please refer to www.littelfuse.com/series/482.html for current information.
482 Series
482 Series Fuseholders
Description
Ideal for telecommunications and control panel circuits,
the 482 Series fuseholder series is designed for use
with Littelfuse 481 Alarm Indicating Fuses. Each holder
is designed to accept other manufacturers replacement
fuses as well.
The fuseholder is available in three versions:
PCB Mount - 15A: Can be soldered directly to a printed
circuit board. Rated up to 15 amperes. Available in single
pole or gangable up to 20 poles. Fuseholder is keyed to
prevent insertion of 20 ampere fuse.
Panel Mount - 20A: Available in a single pole version rated
up to 20 amperes. Large leads for wire attachment.
Panel Mount - 15A: 15 ampere gangable version of
fuseholder is keyed to prevent insertion of 20 ampere fuse.
Agency Approvals
Agency Agency File Number
E71611 (20A Panel Mount Only)
LR 29862
482 Fuseholder Series 15A PCB Mount and Panel Mount 20A Panel Mount
Electrical Rating Rated at 15 amperes up to 125 VAC/ VDC Rated at 20 amperes up to 125 VAC/ VDC
Body Material Thermoplastic (UL 94V-0) Black Phenolic (UL 94V-0)
Fuse Terminal Material Tin-plated Beryllium Copper Tin-plated Copper Alloy
Alarm Terminal Material Tin-plated Brass Tin-plated Copper Alloy
Operating Temperature –55OC to +125OC. –40OC to +85OC.
Thermal Shock Withstands 5 cycles of – 55OC to 125OC Withstands 5 cycles of – 55OC to 125OC
Vibration Per MIL-STD-202F Per MIL-STD-202F
Insulation Resistance
(After Opening) Greater than 10,000 ohms. Greater than 10,000 ohms.
Product Characteristics
Revised: January 7, 2009
Introduction to Circuit Protection
Introduction to Circuit Protection
Transientology
348 © 2009 Littelfuse, Inc.
Specifications are subject to change without notice.
Special Application Fuses
Alarm Indicating Fuseholder 482 Series
482 Series Alarm Indicating Fuse Holder
Please refer to www.littelfuse.com/series/482.html for current information.
15A PCB Mount and Panel Mount Fuseholders
Ordering Information
Type Holder Assembly Length* 15A PCB Mount 15A PCB Mount - Flush 15A Panel Mount 15A Panel Mount - Flush
1 Pole 6.40mm (25”) 0482 0001ZXB 0482 0001ZXBF 0482 0001ZXP 0482 0001ZXPF
2 Pole 12.80mm (.50”) 0482 0002ZXB 0482 0002ZXBF 0482 0002ZXP 0482 0002ZXPF
3 Pole 19.05mm (.75”) 0482 0003ZXB 0482 0003ZXBF 0482 0003ZXP 0482 0003ZXPF
4 Pole 25.04mm (1.0”) 0482 0004ZXB 0482 0004ZXBF 0482 0004ZXP 0482 0004ZXPF
5 Pole 31.75mm (1.25”) 0482 0005ZXB 0482 0005ZXBF 0482 0005ZXP 0482 0005ZXPF
6 Pole 38.10mm (1.50”) 0482 0006ZXB 0482 0006ZXBF 0482 0006ZXP 0482 0006ZXPF
7 Pole 44.45mm (1.75”) 0482 0007ZXB 0482 0007ZXBF 0482 0007ZXP 0482 0007ZXPF
8 Pole 5.80mm (2.00”) 0482 0008ZXB 0482 0008ZXBF 0482 0008ZXP 0482 0008ZXPF
9 Pole 57.15 (2.25”) 0482 0009ZXB 0482 0009ZXBF 0482 0009ZXP 0482 0009ZXPF
10 Pole 63.50mm (2.75”) 0482 0010ZXB 0482 0010ZXBF 0482 0010ZXP 0482 0010ZXPF
11 Pole 69.85mm (2.75”) 0482 0011ZXB 0482 0011ZXBF 0482 0011ZXP 0482 0011ZXPF
12 Pole 76.20mm (3.00”) 0482 0012ZXB 0482 0012ZXBF 0482 0012ZXP 0482 0012ZXPF
13 Pole 82.55mm (3.25”) 0482 0013ZXB 0482 0013ZXBF 0482 0013ZXP 0482 0013ZXPF
14 Pole 88.90mm (3.50”) 0482 0014ZXB 0482 0014ZXBF 0482 0014ZXP 0482 0014ZXPF
15 Pole 95.25mm (3.75”) 0482 0015ZXB 0482 0015ZXBF 0482 0015ZXP 0482 0015ZXPF
16 Pole 101.60mm (4.00”) 0482 0016ZXB 0482 0016ZXBF 0482 0016ZXP 0482 0016ZXPF
17 Pole 107.95mm (4.25”) 0482 0017ZXB 0482 0017ZXBF 0482 0017ZXP 0482 0017ZXPF
18 Pole 114.30mm (4.50”) 0482 0018ZXB 0482 0018ZXBF 0482 0018ZXP 0482 0018ZXPF
19 Pole 120.65mm (4.75”) 0482 0019ZXB 0482 0019ZXBF 0482 0019ZXP 0482 0019ZXPF
20 Pole 127.00mm (5.00”) 0482 0020ZXB 0482 0020ZXBF 0482 0020ZXP 0482 0020ZXPF
20A Panel Mount Fuseholder
Flush Side Options
Available for PCB and
Panel Mount Version
5 POLE HOLDER ASSEMBLY
WITH FLUSH OPTION
Type Holder Length * 20A Panel Mount
1 Pole 6.40mm (25”) 0482 2001ZXPF
* NOTE: 15 ampere gangable version of PCB Mount and Panel Mount fuseholders are keyed to prevent insertion of 20 ampere fuse.
Please refer to A” dimension of diagrams on following page. For additional terminal lengths, please contact Littelfuse.
* NOTE: 20 ampere version of 482 Series Panel Mount fuseholders come standard as a single pole unit with flush edges on
both sides (no “keys” typical with 15A units). Please refer to the diagrams on the following page for additional information.
Revised: January 7, 2009
349
© 2009 Littelfuse, Inc.
Specifications are subject to change without notice.
Special Application Fuses
Alarm Indicating Fuseholder 482 Series
482 Series Alarm Indicating Fuse Holder
Please refer to www.littelfuse.com/series/482.html for current information.
482 Series
Dimensions
FEMALE LATCHING & FLUSH SIDE
WITHOUT TABS
21.3mm
(.84")
TYP
6.4mm
(.25")
TYP
18.5mm
(.73")
12.4mm
(.49")
1.6mm
(.062")
TYP 4.1mm
(.16")
TYP
19.8mm
(.78" )
TYP
.03
6.4mm
(.250") .00510.7mm
(.420") .005
6.4mm
(.250") .005
Ø 2.3mm HOLE
S
(.090")
(3 HOLES)
RECOMMENDED P. C. BOARD
MOUNTING HOLES
Alarm Terminal
TYPICAL HOLDER ASSEMBLY
A
FEMALE & MALE LATCHING
WITH TABS
FEMALE & MALE LATCHING
WITH TABS AND NO MOUNTING HOLES
FEMALE LATCHING & FLUSH SIDE
WITH TABS
37.1mm
(1.46")
6.4mm
(.25")
A
0.6mm
(.025")
TYP
1.6mm
(.062")
TYP
15.7mm
(.62")
9.0mm (.355")
18.5mm
(
.73"
)
.010
12.4mm
(.49" )
.010
24.9mm
(.98" )
.03
21.3mm
(.84")
30.9mm (1.215")
30.7mm (1.210")
TYPICAL HOLDER ASSEMBLY
21.8mm
(.86" )
.005
6.9mm
(.27" )
.005
30.9mm (1.215")
30.7mm (1.210")
Ø 4.1mm
(.160")
MOUNTING HOLE
(2 HOLES)
TYPICAL CUT-OUT IN
PANEL OR CHASSIS
6.4mm
(.25")
21.8mm
(.86" )
.005
6.9mm
(.27" )
.005
6.4mm
(.25")
RECOMMENDED PANEL
MOUNTING HOLES
30.9mm (1.215")
30.7mm (1.210")
30.9mm
(1.212")
Ø 4.1mm
(.160")
MOUNTING HOLE
(2 HOLES)
TYPICAL CUT-OUT IN
PANEL OR CHASSIS
.150''
DIA,
(2 Holes)
21.34mm (.84")
(1.47")
37.34mm
0.6mm
(.025")
TYP
1.6mm
(.062")
TYP
15.7m
m
(.62")
9.0mm (.355")
18.5mm
(.73" )
.010
12.4mm
(.49" )
.010
24.9mm
(.98" )
.03
21.3mm
(.84")
6.4mm
(.25")
NOTE: The 20 ampere single pole holder is designed to
accept all fuse ratings up to 20 amperes.
20 ampere fuseholders should be spaced 12.7mm
(0.50) apart when loaded to maximum capacity, center
to center to insure proper heat dissipation under normal
operation.
Heatsinking may be required for operation in higher
ambient temperatures or alternate configurations.
15A PCB Mount Series: 15A Panel Mount Series:
20A Panel Mount Series:
Mouser Electronics
Authorized Distributor
Click to View Pricing, Inventory, Delivery & Lifecycle Information:
Littelfuse:
04822001ZXPFSH 04820016ZXB 04820003ZXPF 04820015ZXP 04820009ZXP 04820010ZXPF 04820005ZXB
04820012ZXP 04820020ZXB 04820001ZXBF 04820010ZXB 04820005ZXPF 04820018ZXP 04820001ZXBFH
04820004ZXB 04820021ZXP 04822001ZXPF 04820001ZXP 04820013ZXB 04820016ZXBF 04820019ZXB
04820010ZXBF 04820012ZXB 04820002ZXPF 04820004ZXP 04820017ZXB 04820003ZXB 04820008ZXPF
04820007ZXP 04820001ZXB 04820002ZXP 04820007ZXPF 04820021ZXB 04820003ZXP 04820015ZXB
04820005ZXP 04820004ZXPF 04820004ZXBF 04820007ZXBF 04820008ZXP 04820010ZXP 04820008ZXBF
04820014ZXB 04820006ZXPF 04820009ZXB 04820017ZXBF 04820018ZXB 04820006ZXB 04820016ZXP
04820002ZXB 04820006ZXP 04820011ZXP 04820016ZXPF 04820005ZXBF 04820007ZXB 04820011ZXB
04820013ZXP 04820017ZXP 04820008ZXB 04820006ZXBF 04820003ZXBF 04820017ZXPF 04820014ZXP
04820020ZXP 04820002ZXBF 04820001ZXPF 04820019ZXP 04820021ZXPF 04820013ZXPF 04820005ZXBFH
04820005ZXL