Electrical Specs
50-165 Watts
NTQ160 Series
Input
Input range 85-264 VAC
Frequency 47-63 Hz
Inrush current 38 A max., cold start @ 25°C
Efficiency 65% t ypical at full load @ 115 VAC
input
EMI filter FCC Class B conducted and radiated,
CISPR 22 Class B conducted and
radiated, EN55022 Class B conducted
and radiated, VDE 0878 PT3 Class B
conducted and radiated.
Power factor 0.99 t ypical
Safet y ground leakage
current <1 mA @ 50/60 Hz, 264 VAC input
Output
Maximum power 50W convection, 165 W with 30 CFM
forced air
Adjustment range 1.8V - 3.5V; 3.0V - 5.5V on outputs
one and t wo
Hold-up time 20 ms @ 165 W load
Overload protection Shor t circuit protection on all outputs.
Case overload protected @ 110-145%
above peak rating. Latching t ype
recycle AC to reset.
Over voltage protection Tracks outputs 1 & 2: 20% to 35%
above output setting
Standby output 5V@ 2 A regulated ±5%
Logic Control
Power failure T TL logic signal goes high 100-500
msec after V1 output; it goes low at
least 4 msec before loss of regulation
Remote Inhibit Requires contact closure to inhibit
outputs
Remote sense Compensates for 0.5 V lead drop
minimum, will operate without
remote sense connected. Reverse
connection protection.
DC O T TL logic signal goes high after main
output is in regulation. It goes low
when there is a loss of regulation.
Active power factor correction
EN61000-3-2 compliance
Remote sense on outputs
one and t wo
Power fail and remote inhibit
5V Standby output
DC Power good
Single wire current sharing on
outputs one and t wo
Wide range adjustable on outputs 1 & 2
Built-in Class B EMI filter
Over voltage protection
Overload protection
Thermal overload protection
Outputs 3 & 4 are floating
Operating temperature: 0° to 50°C ambient; derate
each output at 2.5% per degree from
50° to 70°C
Electromagnetic susceptibilit y: Designed to meet
EN61000-4, -2, -3, -4, -5, -6, -8, -11 Level 3
Humidit y: Operating; non-condensing
10% to 95%
Vibration: Three orthogonal axes, sweep at
1 oct/min, 5 min. dwell at four major resonances 0.7
G peak 5 Hz to 500 Hz, operational
Storage temperature: -40° to 85°C
Temperature coefficient: ± .04% per °C
MTBF demonstrated: >1 million hours at full load and
25°C ambient conditions
VDE 0805/EN60950 (IEC950) 21310-3336-0021
(129066)
UL UL1950 E186249
CSA CSA 22.2-234 Level 3 LR109492C
NEMKO EN 60950/EMKO-TUE P00100493
(74-sec) 203
BABT EN60950/EN41003 650251, NC/00069
CB Certificate and report 9661, 9662, 8788
CE Mark (LVD)
Environmental
Total Power: 50-165 Watts
Input Voltage: 85-264 VAC
# of Outputs: Quad
Safety
ASIA
Units 2111-2116, Level 21
Tower1, Metroplaza
223, Hing Fong Road
Fwai Fong, New Territories
Hong Kong
Telephone: 852-2437-9662
Facsimile: 852-2402-4426
EUROPE
Astec House, Waterfront Business Park
Merry Hill, Dudley
West Midlands, DY5 1LX, UK
Telephone: 44 (1384) 842-211
Facsimile: 44 (1384) 843-355
AMERICAS
5810 Van Allen Way
Carlsbad, CA 92008
Telephone: 760-930-4600
Facsimile: 760-930-0698
117
www.astecpower.com
C47
L11
C89
C91
C29
C24
Z4
D9
Z1
C84
Q4
D17
VDR1
C86
L4
L12
L7
R48
D23
R78
C72
PRI_DB
T3
D13
R6
R31
D10
C18
C60
C71
C10
L8
C11
L9
R66
L10
L3
C70
B-
SEC_DB
VR2
C63
C77
R39
VR1
F1 250V
F4A
C19
THR3
THR2
C94
C9
R56
R25
R26
R57
R58
R24
R55
R67
D16
L2
R94
C41
R41
B+
B-
D20
R68
C48
L13
C1
C28
C68 C33
C36
C38
C37
R84
R87
Q5
SCR1
C46
R30
C85
T1-W1
R63
SK1
IC6
IC9
C3C2
R64 C42
C43
C31
C22
C21
T1-W1A
D12
Q7 Q8
THR1
C5
R77
THR4
R46
R65
R47
R35
C27
L1
R95
T2
L5
C23
C34
C40
D11
B+
C20
R89
Z2
R80
L6
+
+
+
1
45
9
D13
+
+
1
67
12
P401
+
+
+
R79
+
R32
C67
+
+
+
+
C66
+
+
+
+
+
+
+
+
R42
+
10
1
SO1
C 1999 ASTEC
CUSTOM POWER (PHIL.)
042-66102310D
HTSK-PRI1
SK5
IC8 D24
D21D22
HTSK-SEC3
D27
IC7L15
SK6
110
4
R73
THR5
D18
D19
L6
HTSK-SEC1
SK4
SK3
SK2
SK2
Q2
Q3
R5
Q1
HTSK-RECT
C4
DB1
SK1
HTSK-SEC2
HTSK-PRI2
IC2
R27
D1
VR3
R34
C26
TP1
SK3 SK4
321
SK6
SK1
531
6
7
8
9
10
1
2
3
4
5
SK5
4.25 [108.0]
a
b
a
b
0.75 [19.0]
1.50 [38.1]
6.61 [168.0]
0.95 [24.0]
7.40 [188.0]
0.55 [14.0]
8.50 [216.0]
Model Output Minimum Maximum Load with Maximum Load with Peak Regulation2 Ripple
Num ber Voltage Load Convection Cooling 30 CFM Forced Air Load1 P/P (PARD)3
NTQ162 +3.3 V(1.8 - 3.5V) 2 A 15 A 30 A 38 A ±2% 50 mV
+5 V (3 - 5.5V) 0 A 10 A 20 A 22 A ±2% 50 mV
12 V* 0 A 2 A 4.5 A 5 A ±3% 120 mV
12 V* 0 A 2 A 4.5 A 5 A ±3% 120 mV
NTQ163 +5 V (3 - 5.5V) 2 A 15 A 30 A 32 A ±2% 50 mV
+3.3 V (1.8 - 3.5V) 0 A 10 A 20 A 22 A ±2% 50 mV
12 V* 0 A 2 A 4.5 A 5 A ±3% 120 mV
12 V* 0 A 2 A 4.5 A 5 A ±3% 120 mV
NTQ165 +3.3 V (3 - 5.5V) 2 A 15 A 30 A 32 A ±2% 50 mV
+2.5 V (1.8 - 3.5V) 0 A 10 A 20 A 22 A ±2% 50 mV
5 V* 0 A 2 A 4 A 5 A ±3% 120 mV
12 V* 0 A 2 A 4 A 5 A ±3% 120 mV
* outputs are floating
1. Peak current lasting <30 seconds with a maximum 10% dut y c ycle.
2. At 25°C including initial tolerance, line voltage, load currents and output voltages adjusted to factor y settings.
3. Peak-to -peak with 20 MHz bandwidth and 10 µF in parallel with a 0.1 µF capacitor at rated line voltage and load ranges.
4. Minimum loads are required. In parallel minimum loads are 2.5 A on the V1 output and 1 A on the V2 output for each power supply.
5. Total output current between V1 and V2 is 40A maximum.
Connector
SK1 PIN 1 Ground
PIN 3 Neutral
PIN 5 Live
SK2 V1
SK3 Common
SK4 V2
SK6 PIN 1 V4 Common
PIN 2 V4
PIN 3 V3 Common
PIN 4 V3
SK5 PIN 1 V2 SWP
PIN 2 5V Standby
PIN 3 +V2 Sense
PIN 4 V1 SWP
PIN 5 COMMON
PIN 6 +V1 Sense
PIN 7 Sense COMMON
PIN 8 Remote Inhibit
PIN 9 DC Power Good
PIN 10 Power Fail
Mating Connectors
(SK1) AC Input: Molex: 09-50-8051 (USA)
Molex: 09-91-0500 (UK)
PINS: 08-58-0111
SK2,3,4: Molex BB-124-08
(SK6) ±12V Molex:09-50-8041 (USA)
Molex: 09-91-0400 (UK)
PINS: 08-58-0111
(SK5) Control Signals: Molex: 90142-0010
PINS: 90119-2110
or
Amp: 87977-3
PINS: 87309-8
Astec Connector Kit #70-841-014, includes all of the above
Ordering Information
Ordering Information
NTQ160 Series
Notes:
1. Specifications subject to change without notice.
2. All dimensions in inches (mm), tolerance ±.02”.
3. Remote inhibit requires an external contact closure to
activate
4. Mounting maximum insertion depth is 0.12”.
5. Warranty: 1 year
6. Weight: 2.38 lb. /1.08 kg
C47
L11
C89
C91
C29
C24
Z4
D9
Z1
C84
Q4
D17
VDR1
C86
L4
L12
L7
R48
D23
R78
C72
PRI_DB
T3
D13
R6
R31
D10
C18
C60
C71
C10
L8
C11
L9
R66
L10
L3
C70
B-
SEC_DB
VR2
C63
C77
R39
VR1
F1 250V
F4A
C19
THR3
THR2
C94
C9
R56
R25
R26
R57
R58
R24
R55
R67
D16
L2
R94
C41
R41
B+
B-
D20
R68
C48
L13
C1
C28
C68 C33
C36
C38
C37
R84
R87
Q5
SCR1
C46
R30
C85
T1-W1
R63
SK1
IC6
IC9
C3C2
R64 C42
C43
C31
C22
C21
T1-W1A
D12
Q7 Q8
THR1
C5
R77
THR4
R46
R65
R47
R35
C27
L1
R95
T2
L5
C23
C34
C40
D11
B+
C20
R89
Z2
R80
L6
+
+
+
1
45
9
D13
+
+
1
67
12
P401
+
+
+
R79
+
R32
C67
+
+
+
+
C66
+
+
+
+
+
+
+
+
R42
+
10
1
SO1
C 1999 ASTEC
CUSTOM POWER (PHIL.)
042-66102310D
HTSK-PRI1
SK5
IC8 D24
D21D22
HTSK-SEC3
D27
IC7L15
SK6
110
4
R73
THR5
D18
D19
L6
HTSK-SEC1
SK4
SK3
SK2
SK2
Q2
Q3
R5
Q1
HTSK-RECT
C4
DB1
SK1
HTSK-SEC2
HTSK-PRI2
IC2
R27
D1
VR3
R34
C26
TP1
SK3 SK4
321
SK6
SK1
531
6
7
8
9
10
1
2
3
4
5
SK5
4.25 [108.0]
a
b
a
b
a
b
a
b
a
b
a
b
0.75 [19.0]
1.50 [38.1]
6.61 [168.0]
0.95 [24.0]
7.40 [188.0]
0.55 [14.0]
8.50 [216.0]
0.88 [22.3] 2.50 [63.5]
1.07 [27.3] 2.11 [53.5] #6-32 (8 PLACES)
M3 (8 PLACES)
NTQ160 SSeries