2012-06-27 1
2012-06-27
OSRAM OSTAR Projection Compact
Datasheet
Version 2.0
LE A Q9WP
Compact light source in SMT technology, glass
window on top, RoHS compliant
Kompakte Lichtquelle in SMT Technologie,
Abdeckung mit Glasfenster, RoHS konform
Features: Besondere Merkmale:
Package: compact lightsource in SMT
technology with glass window on top
Gehäusetyp: Kompakte Lichtquelle in SMT
Technologie mit Glasabdeckung
Technology: InGaAlP Technologie: InGaAlP
Color: amber (617 nm) Farbe: amber (617 nm)
ESD-withstand voltage: 2 kV acc. to
JESD22-A114-F
ESD-Festigkeit: 2 kV nach JESD22-A114-F
Viewing angle at 50 % IV: 120° • Abstrahlwinkel bei 50 % IV: 120°
Applications Anwendungen
Projection Projektion
2012-06-27 2
Version 2.0 LE A Q9WP
Ordering Information
Bestellinformation
Type Luminous Flux 1) page 19 Ordering Code
Typ Lichtstrom 1) Seite 19 Bestellnummer
IF = 1400 mA
ΦV [lm]
LE A Q9WP-KZLZ-1 97 ... 180 Q65110A9145
Note: The above Type Numbers represent the order groups which include only a few brightness groups (see page 5 for explanation). Only one group will
be shipped on each packing unit (there will be no mixing of two groups on each packing unit). E. g. LE A Q9WP-KZLZ-1 means that only one group
KZ, LX, LY, LZ will be shippable for any packing unit. In order to ensure availability, single brightness groups will not be orderable.
Anm.: Die oben genannten Typbezeichnungen umfassen die bestellbaren Selektionen. Diese bestehen aus wenigen Helligkeitsgruppen (siehe Seite 5 für
nähere Informationen). Es wird nur eine einzige Helligkeitsgruppe pro Verpackungseinheit geliefert. Z. B. LE A Q9WP-KZLZ-1 bedeutet, dass in einer
Verpackungseinheit nur eine der Helligkeitsgruppen KZ, LX, LY, LZ enhalten ist. Um die Liefersicherheit zu gewährleisten, können einzelne
Helligkeitsgruppen nicht bestellt werden.
Version 2.0 LE A Q9WP
2012-06-27 3
Maximum Ratings
Grenzwerte
Parameter Symbol Values Unit
Bezeichnung Symbol Werte Einheit
Operating temperature range
Betriebstemperatur
Top -40 ... 100 °C
Storage temperature range
Lagertemperatur
Tstg -40 ... 100 °C
Junction temperature
Sperrschichttemperatur
Tj100 °C
Forward current
Durchlassstrom
(TS = 25 °C)
IF200 ... 3500 mA
Forward current pulsed
Durchlassstrom gepulst
(D = 0.5; f = 120 Hz; TS = 25 °C)
IF pulse 200 ... 4500 mA
Reverse voltage
Sperrspannung
(TS = 25 °C)
VRnot designed for reverse operation V
2012-06-27 4
Version 2.0 LE A Q9WP
Characteristics (TS = 25 °C; IF = 1400 mA)
Kennwerte
Parameter Symbol Values Unit
Bezeichnung Symbol Werte Einheit
Wavelength at peak emission
Wellenlänge d. emittierten Lichtes
(typ.) λpeak 624 nm
Dominant Wavelength 2) page 19
Dominantwellenlänge 2) Seite 19
(min.)
(typ.)
(max.)
λdom
λdom
λdom
612
617
624
nm
nm
nm
Spectral bandwidth at 50% Irel max
Spektrale Bandbreite b. 50% Irel max
(typ.) Δλ 18 nm
Viewing angle at 50 % IV
Abstrahlwinkel bei 50 % IV
(typ.) 2ϕ120 °
Forward voltage 3) page 19
Durchlassspannung 3) Seite 19
(min.)
(typ.)
(max.)
VF
VF
VF
2.00
2.30
2.90
V
V
V
Reverse current
Sperrstrom
IRnot designed for reverse operation
Partial Flux acc. CIE 127:2007
Partieller Fluss
(ΦV 120° = x * ΦV 180°)
(typ.) ΦE/V, 120° 0.82
Radiating surface
Abstrahlende Fläche
(typ.) Acolor 1.5 x 1.2 mm2
Real thermal resistance junction /
solder point 4) page 19
Realer Wärmewiderstand
Sperrschicht / Lötpad 4) Seite 19
(typ.)
(max.)
Rth JS real
Rth JS real
3
4
K/W
K/W
"Electrical" thermal resistance
junction / solder point 4) page 19
"Elektrischer" Wärmewiderstand
Sperrschicht / Lötpad 4) Seite 19
(with efficiency ηe = 17 %)
(typ.)
(max.)
Rth JS el
Rth JS el
2.5
3.3
K/W
K/W
Version 2.0 LE A Q9WP
2012-06-27 5
Brightness Groups
Helligkeits-Gruppierungsschema
Group Name on Label
Gruppenbezeichnung auf Etikett
Example: KZ
Beispiel: KZ
Group Luminous Flux 1) page 19 Luminous Flux 1) page 19
Gruppe Lichtstrom 1) Seite 19 Lichtstrom 1) Seite 19
(min.) ΦV [lm] (max.) ΦV [lm]
KZ 97 112
LX 112 130
LY 130 150
LZ 150 180
Note: The standard shipping format for serial types includes either a lower family group, an upper family group
or a grouping of all individual brightness groups of only a few brightness groups. Individual brightness
groups cannot be ordered.
Anm.: Die Standardlieferform von Serientypen beinhaltet entweder eine untere Familiengruppe, eine obere
Familiengruppe oder eine Sammelgruppe, die aus nur wenigen Helligkeitsgruppen bestehen. Einzelne
Helligkeitsgruppen sind nicht bestellbar.
Brightness
Helligkeit
KZ
Note: No packing unit / tape ever contains more than one group for each selection.
Anm.: In einer Verpackungseinheit / Gurt ist immer nur eine Gruppe für jede Selektion enthalten.
2012-06-27 6
Version 2.0 LE A Q9WP
Relative Spectral Emission - V(λ) = Standard eye response curve 5) page 19 , 1) page 19
Relative spektrale Emission - V(λ) = spektrale Augenempfindlichkeit 5) Seite 19 , 1) Seite 19
Φrel = f (λ); TJ = 25 °C; IF = 1400 mA
Radiation Characteristics 5) page 19
Abstrahlcharakteristik 5) Seite 19
Irel = f (ϕ); TJ = 25 °C
OHL00436
400
0
20
40
60
80
100
450 500 550 600 650 700nm
%
rel
λ
V
λ
amber
Φ
OHL03736
20˚ 40˚ 60˚ 80˚ 100˚ 120˚0.40.60.81.0
100˚
90˚
80˚
70˚
60˚
50˚
10˚20˚30˚40˚
0
0.2
0.4
0.6
0.8
1.0
ϕ
Version 2.0 LE A Q9WP
2012-06-27 7
Relative partial flux 5) page 19
Relativer zonaler Lichtstromanteil 5) Seite 19
ΦV(2ϕ)/ΦV(180°) = f (ϕ); TJ = 25 °C
010 20 30 40 50 60 70 80 90 100 110 120 130 140 150 160 170 180
2*ϕ [°]
0.0
0.1
0.2
0.3
0.4
0.5
0.6
0.7
0.8
0.9
1.0
Φ
V
(ϕ)
Φ
V
(180°)
2
2012-06-27 8
Version 2.0 LE A Q9WP
Forward Current 5) page 19
Durchlassstrom 5) Seite 19
IF = f (VF); TJ = 25 °C
Relative Luminous Flux 5) page 19 , 6) page 19
Relativer Lichtstrom 5) Seite 19 , 6) Seite 19
ΦV/ΦV(1400 mA) = f(IF); TJ = 25 °C
2,0 2,5 3,0 3,5
VF [V]
1
2
3
4
IF [A]
OHL04771
28IB120045007
1000 2000 3000 4000
I
F
[mA]
0.0
0.5
1.0
1.5
2.0
2.5
3.0
Φ
v
Φ
v
(1400 mA )
Version 2.0 LE A Q9WP
2012-06-27 9
Relative Forward Voltage 5) page 19
Relative Vorwärtsspannung 5) Seite 19
ΔVF = VF - VF(25°C) = f(Tj); IF = 1400 mA
Relative Luminous Flux 5) page 19
Relative Lichtstrom 5) Seite 19
ΦV/ΦV(25 °C) = f(Tj); IF = 1400 mA
Dominant Wavelength 5) page 19
Dominante Wellenlänge 5) Seite 19
Δλdom = λdom - λdom (25 °C) = f(Tj); IF = 1400 mA
-40
-0.15 ˚C
T
j
OHL04417
V
F
V
Δ
-20 0 20 40 60 80 120
-0.10
-0.05
0
0.05
0.10
0.15
0.25
OHL14419
-40 ˚C
j
T
-20 0 20 40 60 80 120
0
V
V(25 ˚C)
Φ
Φ
0.2
0.4
0.6
0.8
1.0
1.2
1.6
OHL04422
-6
Δλdom
nm
j
T
-40 200-20 806040 ˚C 120
-4
-2
0
2
4
6
8
2012-06-27 10
Version 2.0 LE A Q9WP
Max. Permissible Forward Current 7) page 19
Maximal zulässiger Durchlassstrom 7) Seite 19
IF = f (T)
LE A Q9WP
020406080100
T
S
C]
0
500
1000
1500
2000
2500
3000
3500
I
F
[mA]
: T
A
Version 2.0 LE A Q9WP
2012-06-27 11
Package Outline 8) page 19
Maßzeichnung 8) Seite 19
Approximate Weight: 60 mg
Gewicht: 60 mg
2012-06-27 12
Version 2.0 LE A Q9WP
Recommended Solder Pad 8) page 19 Reflow soldering
Empfohlenes Lötpaddesign 8) Seite 19 Reflow-Löten
Version 2.0 LE A Q9WP
2012-06-27 13
Reflow Soldering Profile
Reflow Lötprofil
Preconditioning: JEDEC Level 2 acc. to J-STD-020D.01
0
0s
OHA04525
50
100
150
200
250
300
50 100 150 200 250 300
t
T
˚C
S
t
t
P
t
T
p
240 ˚C
217 ˚C
245 ˚C
25 ˚C
L
OHA04612
Profil-Charakteristik
Profile Feature
Ramp-up Rate to Preheat*)
25 °C to 150 °C
23K/s
Time tS
TSmin to TSmax
tS
tL
tP
TL
TP
100 12060
10 20 30
80 100
217
23
245 260
36
Time
25 °C to TP
Time within 5 °C of the specified peak
temperature TP - 5 K
Ramp-down Rate*
TP to 100 °C
All temperatures refer to the center of the package, measured on the top of the component
* slope calculation DT/Dt: Dt max. 5 s; fulfillment for the whole T-range
Ramp-up Rate to Peak*)
TSmax to TP
Liquidus Temperature
Peak Temperature
Time above Liquidus temperature
Symbol
Symbol
Einheit
Unit
Pb-Free (SnAgCu) Assembly
Minimum MaximumRecommendation
K/s
K/s
s
s
s
s
°C
°C
480
2012-06-27 14
Version 2.0 LE A Q9WP
Method of Taping 8) page 19
Gurtung 8) Seite 19
Version 2.0 LE A Q9WP
2012-06-27 15
Tape and Reel
Gurtverpackung
12 mm tape with 500 pcs. on 180 mm reel
Tape dimensions in mm (inch)
Tape dimensions in mm (inch)
Reel dimensions in mm (inch)
Reel dimensi ons in mm (inc h)
W P0P1P2D0E F
12 +0.3/-0.1 4 ± 0.1
(0.157 ±
0.004)
4 ± 0.1
(0.157 ±
0.004)
or
8 ± 0.1
(0.315 ±
0.004)
2 ± 0.05
(0.079 ±
0.002)
1.5 ± 0.1
(0.059 +
0.004)
1.75 ± 0.1
(0.069 ±
0.004)
5.5 ± 0.05
(0.217 ±
0.002)
A W Nmin W1W2max
180 (7) 12 (0.472) 60 (2.362) 12.4 + 2 (0.488 +
0.079)
18.4 (0.724)
D0
2
P
P0
1
P
W
FE
Direction of unreeling
N
W1
2
W
A
OHAY0324
Label
Gurtvorlauf:
Leader:
Trailer:
Gurtende:
13.0
Direction of unreeling
±0.25
160 mm
160 mm
400 mm
400 mm
2012-06-27 16
Version 2.0 LE A Q9WP
Barcode-Product-Label (BPL)
Barcode-Produkt-Etikett (BPL)
Dry Packing Process and Materials
Trockenverpackung und Materialien
Note: Moisture-sensitive product is packed in a dry bag containing desiccant and a humidity card.
Regarding dry pack you will find further information in the internet and in the Short Form Catalog in
chapter “Tape and Reel” under the topic “Dry Pack”. Here you will also find the normative references
like JEDEC.
Anm.: Feuchteempfindliche Produkte sind verpackt in einem Trockenbeutel zusammen mit einem
Trockenmittel und einer Feuchteindikatorkarte.
Bezüglich Trockenverpackung finden Sie weitere Hinweise im Internet und in unserem Short Form
Catalog im Kapitel “Gurtung und Verpackung” unter dem Punkt “Trockenverpackung”. Hier sind
Normenbezüge, unter anderem ein Auszug der JEDEC-Norm, enthalten.
OHA04563
(G) GROUP:
1234567890
(1T) LOT NO: (9D) D/C:
1234
(X) PROD NO:
123456789
(6P) BATCH NO:
1234567890
LX XXXX
RoHS Compliant
BIN1: XX-XX-X-XXX-X
ML
2
Temp ST
260 °C R
Pack: R18
DEMY 022
B_R999_1880.1642 R
9999
(Q)QTY:
Semiconductors
OSRAM Opto
XX-XX-X-X
OHA00539
OSRAM
Moisture-sensitive label or print
Barcode label
Desiccant
Humidity indicator
Barcode label
OSRAM
Please check the HIC immidiately after
bag opening.
Discard if circles overrun.
Avoid metal contact.
WET
Do not eat.
Comparator
check dot
parts still adequately dry.
examine units, if necessary
examine units, if necessary
5%
15%
10%
bake units
bake units
If wet,
change desiccant
If wet,
Humidity Indicator
MIL-I-8835
If wet,
Moisture Level 3 Floor time 168 HoursMoisture Level 6 Floor time 6 Hours
a) Humidity Indicator Card is > 10% when read at 23 ˚C ± 5 ˚C, or
reflow, vapor-phase reflow, or equivalent processing (peak package
2. After this bag is opened, devices that will be subjected to infrared
1. Shelf life in sealed bag: 24 months at < 40 ˚C and < 90% relative humidity (RH).
Moisture Level 5a
at factory conditions of
(if blank, seal date is identical with date code).
a) Mounted within
b) Stored at
body temp.
3. Devices require baking, before mounting, if:
Bag seal date
Moisture Level 1
Moisture Level 2
Moisture Level 2a
4. If baking is required,
b) 2a or 2b is not met.
Date and time opened:
reference IPC/JEDEC J-STD-033 for bake procedure.
Floor time see below
If blank, see bar code label
Floor time > 1 Year
Floor time 1 Year
Floor time 4 Weeks
10% RH.
_
<
Moisture Level 4
Moisture Level 5
˚C).
OPTO SEMICONDUCTORS
MOISTURE SENSITIVE
This bag contains
CAUTION
Floor time 72 Hours
Floor time 48 Hours
Floor time 24 Hours
30 ˚C/60% RH.
_
<
LEVEL
If blank, see
bar code label
Version 2.0 LE A Q9WP
2012-06-27 17
Transportation Packing and Materials
Kartonverpackung und Materialien
Width / Breite Length / Länge Height / Höhe
195 ±5 (7,677 ±0,1968) 195 ±5 (7,677 ±0,1968) 30 ±5 (1,181 ±0,196)
Notes Hinweise
The evaluation of eye safety occurs according to the
standard IEC 62471:2006 ("photobiological safety
of lamps and lamp systems"). Within the risk
grouping system of this CIE standard, the LED
specified in this data sheet fall into the class Low
risk (exposure time 100 s). Under real
circumstances (for exposure time, eye pupils,
observation distance), it is assumed that no
endangerment to the eye exists from these devices.
As a matter of principle, however, it should be
mentioned that intense light sources have a high
secondary exposure potential due to their blinding
effect. As is also true when viewing other bright light
sources (e.g. headlights), temporary reduction in
visual acuity and afterimages can occur, leading to
irritation, annoyance, visual impairment, and even
accidents, depending on the situation.
Die Bewertung der Augensicherheit erfolgt nach
dem Standard IEC 62471:2006 ("photobiological
safety of lamps and lamp systems"). Im
Risikogruppensystem dieser CIE- Norm erfüllen die
in diesem Datenblatt angegebenen LEDs folgende
Gruppenanforderung - Low risk (Expositionsdauer
100s). Unter realen Umständen (für
Expositionsdauer, Augenpupille,
Betrachtungsabstand) geht damit von diesen
Bauelementen keinerlei Augengefährdung aus.
Grundsätzlich sollte jedoch erwähnt werden, dass
intensive Lichtquellen durch ihre Blendwirkung ein
hohes sekundäres Gefahrenpotenzial besitzen.
Nach einem Blick in eine helle Lichtquelle (z.B.
Autoscheinwerfer), kann ein temporär
eingeschränktes Sehvermögen oder auch
Nachbilder zu Irritationen, Belästigungen,
Beeinträchtigungen oder sogar Unfällen führen.
OHA02044
PACKVAR:
R077
Additional TEXT
P-1+Q-1
Multi TOPLED
Muster
OSRAM Opto
Semiconductors
(6P) BATCH NO:
(X) PROD NO:
1
0
(9D) D/C:
11
(1T) LOT NO:
210021998
123GH1234
0245
(Q)QTY:
2000
0144
(G) GROUP:
260 C RT
240 C R
3
220 C R
ML
Bin3:
Bin2: Q-1-20
Bin1: P-1-20
LSY T676
2
2a
Temp ST
R18
DEMY
PACKVAR:
R077
Additional TEXT
P-1+Q-1
Multi TOPLED
Muster
OSRAM Opto
Semiconductors
(6P) BATCH NO:
(X) PROD NO:
1
0
(9D) D/C:
11
(1T) LOT NO:
210021998
123GH1234
0245
(Q)QTY:
2000
0144
(G) GROUP:
260 C RT
240 C R
3
220 C R
ML
Bin3:
Bin2: Q-1-20
Bin1: P-1-20
LSY T676
2
2a
Temp ST
R18
DEMY
OSRAM
Packing
Sealing label
Barcode label
Moisture Level 3 Floor time 168 Hours Moisture Level 6 Floor time 6 Hours
a) Humidity Indicator Card is > 10% when read at 23 ˚C ± 5 ˚C, or
reflow, vapor-phase reflow, or equivalent processing (peak package
2. After this bag is opened, devices that will be subjected to infrared
1. Shelf life in sealed bag: 24 months at < 40 ˚C and < 90% relative humidity (RH).
Moisture Level 5a
at factory conditions of
(if blank, seal date is identical with date code).
a) Mounted within
b) Stored at
body temp.
3. Devices require baking, before mounting, if:
Bag seal date
Moisture Level 1
Moisture Level 2
Moisture Level 2a
4. If baking is required,
b) 2a or 2b is not met.
Date and time opened:
reference IPC/JEDEC J-STD-033 for bake procedure.
Floor time see below
If blank, see bar code label
Floor time > 1 Year
Floor time 1 Year
Floor time 4 Weeks
10% RH.
_
<
Moisture Level 4
Moisture Level 5
˚C).
OPTO SEMICONDUCTORS
MOISTURE SENSITIVE
This bag contains
CAUTION
Floor time 72 Hours
Floor time 48 Hours
Floor time 24 Hours
30 ˚C/60% RH.
_
<
LEVEL
If blank, see
bar code label
Barcode label
2012-06-27 18
Version 2.0 LE A Q9WP
Disclaimer Disclaimer
Attention please!
The information describes the type of component and
shall not be considered as assured characteristics.
Terms of delivery and rights to change design reserved.
Due to technical requirements components may contain
dangerous substances.
For information on the types in question please contact
our Sales Organization.
If printed or downloaded, please find the latest version
in the Internet.
Packing
Please use the recycling operators known to you. We
can also help you – get in touch with your nearest sales
office.
By agreement we will take packing material back, if it is
sorted. You must bear the costs of transport. For
packing material that is returned to us unsorted or which
we are not obliged to accept, we shall have to invoice
you for any costs incurred.
Components used in life-support devices or
systems must be expressly authorized for such
purpose!
Critical components* may only be used in life-support
devices** or systems with the express written approval
of OSRAM OS.
*) A critical component is a component used in a
life-support device or system whose failure can
reasonably be expected to cause the failure of that
life-support device or system, or to affect its safety or
the effectiveness of that device or system.
**) Life support devices or systems are intended(a) to
be implanted in the human body,or(b) to support and/or
maintain and sustain human life.If they fail, it is
reasonable to assume that the health and the life of the
user may be endangered.
Bitte beachten!
Lieferbedingungen und Änderungen im Design
vorbehalten. Aufgrund technischer Anforderungen
können die Bauteile Gefahrstoffe enthalten. Für weitere
Informationen zu gewünschten Bauteilen, wenden Sie
sich bitte an unseren Vertrieb.Falls Sie diese Datenblatt
ausgedruckt oder heruntergeladen haben, finden Sie
die aktuellste Version im Internet.
Verpackung
Benutzen Sie bitte die Ihnen bekannten
Recyclingwege. Wenn diese nicht bekannt sein sollten,
wenden Sie sich bitte an das nächstgelegene
Vertriebsbüro. Wir nehmen das Verpackungsmaterial
zurück, falls dies vereinbart wurde und das Material
sortiert ist. Sie tragen die Transportkosten. Für
Verpackungsmaterial, das unsortiert an uns
zurückgeschickt wird oder das wir nicht annehmen
müssen, stellen wir Ihnen die anfallenden Kosten in
Rechnung.
Bauteile, die in lebenserhaltenden Apparaten und
Systemen eingesetzt werden, müssen für diese
Zwecke ausdrücklich zugelassen sein!
Kritische Bauteile* dürfen in lebenserhaltenden
Apparaten und Systemen nur dann eingesetzt werden,
wenn ein schriftliches Einverständnis von OSRAM OS
vorliegt.
*) Ein kritisches Bauteil ist ein Bauteil, das in
lebenserhaltenden Apparaten oder Systemen
eingesetzt wird und dessen Defekt voraussichtlich zu
einer Fehlfunktion dieses lebenserhaltenden Apparates
oder Systems führen wird oder die Sicherheit oder
Effektivität dieses Apparates oder Systems
beeinträchtigt.
**) Lebenserhaltende Apparate oder Systeme sind für
(a) die Implantierung in den menschlichen Körper oder
(b) für die Lebenserhaltung bestimmt. Falls Sie
versagen, kann davon ausgegangen werden, dass die
Gesundheit und das Leben des Patienten in Gefahr ist.
Version 2.0 LE A Q9WP
2012-06-27 19
Glossary Glossar
1) Brightness: Brightness values are measured
during a current pulse of typical 25 ms, with an
internal reproducibility of +/- 8 % and an expanded
uncertainty of +/- 11 % (acc. to GUM with a coverage
factor of k = 3).
1) Helligkeit: Helligkeitswerte werden während eines
Strompulses einer typischen Dauer von 25 ms, mit
einer internen Reproduzierbarkeit von +/- 8 % und
einer erweiterten Messunsicherheit von +/- 11 %
gemessen (gemäß GUM mit Erweiterungsfaktor k =
3).
2) Wavelength: The wavelength is measured at a
current pulse of typical 25 ms, with an internal
reproducibility of ± 0,5 nm and an expanded
uncertainty of ± 1 nm (acc. to GUM with a coverage
factor of k=3).
2) Wellenlänge: Die Wellenläge wird während eines
Strompulses einer typischen Dauer von 25 ms, mit
einer internen Reproduzierbarkeit von ± 0,5 nm und
einer erweiterten Messunsicherheit von ± 1 nm
gemessen (gemäß GUM mit Erweiterungsfaktor
k=3).
3) Forward Voltage: The forward voltage is
measured during a current pulse of typical 8 ms, with
an internal reproducibility of +/- 0,05 V and an
expanded uncertainty of +/- 0,1 V (acc. to GUM with
a coverage factor of k=3).
3) Durchlassspannung: Vorwärtsspannungen
werden während eines Strompulses einer typischen
Dauer von 8 ms, mit einer internen
Reproduzierbarkeit von +/- 0,05 V und einer
erweiterten Messunsicherheit von +/- 0,1 V
gemessen (gemäß GUM mit Erweiterungsfaktor
k=3).
4) Thermal Resistance: Rth max based on statistic
values (6ó)
4) Wärmewiderstand: Rth max basiert auf
statistischen Werten (6ó)
5) Typical Values: Due to the special conditions of
the manufacturing processes of LED, the typical
data or calculated correlations of technical
parameters can only reflect statistical figures. These
do not necessarily correspond to the actual
parameters of each single product, which could
differ from the typical data and calculated
correlations or the typical characteristic line. If
requested, e.g. because of technical improvements,
these typ. data will be changed without any further
notice.
5) Typische Werte: Wegen der besonderen
Prozessbedingungen bei der Herstellung von LED
können typische oder abgeleitete technische
Parameter nur aufgrund statistischer Werte
wiedergegeben werden. Diese stimmen nicht
notwendigerweise mit den Werten jedes einzelnen
Produktes überein, dessen Werte sich von
typischen und abgeleiteten Werten oder typischen
Kennlinien unterscheiden können. Falls erforderlich,
z.B. aufgrund technischer Verbesserungen, werden
diese typischen Werte ohne weitere Ankündigung
geändert.
6) Relative Brightness Curve: In the range
where the line of the graph is broken, you must
expect higher brightness differences between single
LEDs within one packing unit.
6) Relative Helligkeitskurve: Im gestrichelten
Bereich der Kennlinien muss mit erhöhten
Helligkeitsunterschieden zwischen Leuchtdioden
innerhalb einer Verpackungseinheit gerechnet
werden.
7) Thermal Resistance: RthJA results from
mounting on PC board FR 4 (pad size 16mm2 per
pad)
7) Wärmewiderstand: RthJA ergibt sich bei
Montage auf PC-Board FR 4 (Padgröße 16mm2 je
pad)
8) Tolerance of Measure: Dimensions are
specified as follows: mm (inch).
8) Maßtoleranz: Maße werden wie folgt
angegeben: mm (inch).
Version 2.0 LE A Q9WP
2012-06-27 20
Published by OSRAM Opto Semiconductors GmbH
Leibnizstraße 4, D-93055 Regensburg
www.osram-os.com © All Rights Reserved.