3
G6E G6E
Note: 1. The rated current and coil resistance are measured at a coil temperature of 23°C (73°F) with a tolerance of ±10%.
2. The operating characteristics are measured at a coil temperature of 23°C (73°F).
■COIL DATA (continued)
Contact resistance 50 mΩ max.
Operate (set) time 5 ms max. (mean value approx. 2.90 ms, 48 VDC type, approx. 2.40 ms)
Release (reset) time 5 ms max. (mean value approx. 1.30 ms)
Bounce time Operate Approx. 3 ms (mean value 0.37 ms)
Release Approx. 3 ms (mean value 1.12 ms)
Operating Mechanical 36,000 operations/hour
frequency Electrical 1,800 operations/hour (under rated load)
Insulation resistance 1,000 MΩ min. (at 500 VDC)
Dielectric strength 1,500 VAC, 50/60 Hz for 1 minute between coil and contacts
1,000 VAC, 50/60 Hz for 1 minute between contacts of same pole
Surge withstand voltage 1,500 V 10 x 160 µs (conforms to par t 68 of FCC Rules)
2,500 V 2 x 10 µs (Bellcore Requirement)
Vibration Mechanical durability 10 to 55 Hz; 5 mm (0.20 in) double amplitude
Malfunction durability 10 to 55 Hz; 3.3 mm (0.13 in) double amplitude
Shock Mechanical durability 1,000 m/s2 (approx. 100 G)
Malfunction durability 300 m/s2 (approx. 30 G)
Ambient temperature -40 to 70°C (-40° to 158°F)
Humidity 45% to 85% RH
Ser vice life Mechanical 1 million operations min. (at 36,000 operations/hour)
Electrical See “Characteristic Data”
Weight Approx. 2.7 g (0.10 oz)
Note: Data shown are of initial value.
■CHARACTERISTICS
Standard dual coil latching type (G6EK-134P-ST-US)
Coil inductance Set Reset
Rated Rated Coil (ref. value) (H) pick-up pick-up Maximum Power
voltage current resistance Armature Armature voltage voltage voltage
consumption
(VDC) (mA) (Ω)OFF ON % of rated voltage (mW)
3 66.70 45 0.03 0.03 70% max. 70% min. 190% max. Approx. 200
5 40 125 0.09 0.08 at 23°C
6 33.30 180 0.12 0.11 (73°F)
7 22.20 405 0.25 0.22 130% max.
12 16.70 720 0.44 0.41 at 70°C
24 8.30 2,880 1.66 1.62 (158°F)
Low-sensitivity dual coil latching type (G6EK-134PL-ST-US)
Coil inductance Set Reset
Rated Rated Coil (ref. value) (H) pick-up pick-up Maximum Power
voltage current resistance Armature Armature voltage voltage voltage
consumption
(VDC) (mA) (Ω)OFF ON % of rated voltage (mW)
3 133 22.50 0.02 0.01 70% max. 70% min. 170% max. Approx. 400
5 79.40 63 0.04 0.03 at 23°C
6 66.60 90 0.06 0.04 (73°F)
9 44.30 203 0.12 0.09 115% max.
12 33.30 360 0.21 0.15 at 70°C
24 16.70 1,440 0.80 0.58 (158°F)