Enclosed 150 Watt Switching Power Supplies US150 series
300 Myles Standish Blvd., Taunton, MA 02780
Ph: 1-800-823-8082 Fax: 508-823-8181
WWW.ASTRODYNE.COM
Universal 85-265VAC Input
High Efficiency
Regulated Outputs
3000V Isolation
Built in EMI Filter
Low Cost Solution
Model Number Output Voltage Output Amps (max)
SINGLE OUTPUT
US150-5 5 VDC 30
US150-12 12 VDC 12.5
US150-15 15 VDC 10
US150-24 24 VDC 6.5
Order On-Line!
astrodyne.com
Unit measures 4.4”W x 7.96”L x 2”H
Enclosed 150 Watt Switching Power Supplies US150 series
300 Myles Standish Blvd., Taunton, MA 02780
Ph: 1-800-823-8082 Fax: 508-823-8181
WWW.ASTRODYNE.COM
INPUT SPECIFICATIONS
Input Voltage Range Universal 85-265 VAC
Frequency Range 47-63 Hz
Inrush Current, typ: 35A *
OUTPUT SPECIFICATIONS
Voltage and Current See Selection Chart
Line/Load Regulation
(10% to 100% Load) +/- 0.3%, typ
Voltage Tolerance 5V: +/-5%, typ
All Others: +/-1%
DC Voltage Adjust (typ) +/-10%, typ
Temperature Coefficient +/-0.03%/°C
Ripple/Noise 5V: 150mV, typ
12V, 15V: 180mV, typ
24V: 240mV, typ
Over Voltage Protection Clamp, 115-135%, typ *
Short Circuit Protection Continuous, self-recovering
Setup, Rise, Hold Up Time 100mS, 50mS, 20mS
GENERAL SPECIFICATIONS
Isolation I/P-O/P: 3000VAC
I/P-Ground: 1500VAC
Efficiency 82%, typ
Switching Frequency 25Khz, (fixed, typical)
ENVIRONMENTAL SPECIFICATIONS
Oper. Temperature -10 to +60°C(See Derate)
Storage Temperature -20 to +85°C *
Relative Humidity 20% to +90%, non-cond *
EMC CISPR22 (EN55022)
IEC1000-4-2,3,4,5
MTBF 860 kHrs
Mil Std 217, 25°C
PHYSICAL SPECIFICATIONS
Size 4.4” x 7.96” x 2.0”
Construction Enclosed, Perf Cover
Weight 1.76 lb, (800g)
* These are stress ratings. Exposure of the devices to any of these conditions
may adversely affect long term reliability. Proper operation under conditions
other than the standard operating conditions is neither warranteed nor implied.
All specifications are typical at nominal input, full load, and 25°C unless other-
wise noted Astrodyne products are not authorized or warranteed for use
as critical components in life support systems, equipment used
in hazardous environments, nuclear controls systems, or other
mission-critical applications.
Enclosed 150 Watt Switching Power Supplies US150 series
300 Myles Standish Blvd., Taunton, MA 02780
Ph: 1-800-823-8082 Fax: 508-823-8181
WWW.ASTRODYNE.COM
0.78 (20) 6.26 (159)
7.83 (199)
3.94 (100)
6.77 (172)
0.19 (5)
7.56 (192)
5-M3
7.5 (190.5)
0.24 (6)
3
M-3
1.97 (50)
0.65 (16.5)
0.96 (24.5)
0.98 (25)
0.47
(12)
0.25
(6.5)
0.24
(6)
0.14 (3.5) 0.14 (3.5)
0.79 (20) 3.82 (97)
0.32 (8.2)
4.33 (110)
0.37 (9.5) 0.47 (12)
5
.
3
7
6
5
4
3
2
1
Dimensions are Inches (mm)
OUTPUT DERATING CURVE
MECHANICAL DIMENSIONS
Pin # Outputs
1 AC Line
2 AC Neutral
3 FG
4 - Output
5 - Output
6 + Output
7 + Output
(HORIZONTAL)
(VERTICAL)
-10
-10
0 10 20 30 40 50
45
60
55
20
40
60
80
100
US150-15, -24
US150-5, -12