M6X1
'X'
47.8
'Y'
34.5
19.00
±0.25
11.11mm
ACROSS
FLATS
1
2
3
31.8
0.62
3.18
31.8
0.62
50.8
25.4
50.8
MOUNTING FEET (2)
3.962 x 7.925 (SLOT)
12.7
6.4
4.1
42.7
21.3
1
2
3
SCHEMATIC
SHAFT EXTENDED
(CONNECTOR END)
www.honeywell.com/sensing/products/di
L
ONGFELLOW
®
II M
ETRIC
S
ERIES
•
LINEAR
POSITION
TRANSDUCER
TECHNICAL SPECIFICATIONS
Sensing and Control
Honeywell
100 Discov ery Way
Acton, MA 01720 USA
T el: (877) 384-1300; Fax: (978) 263-0630
WARRANTY/REMEDY
Honeywell warrants goods of its manufacture as being free of defective materials and faulty workmanship. Contact your local
sales office for warranty information. If warranted goods are returned to Honeywell during the period of coverage, Honeywell
will repair or replace without charge those items it finds defective. The foregoing is Buyer’s sole remedy and is in lieu of all other
warranties, expressed or implied, including those of merchantability and fitness for a particular purpose.
Specifications may change without notice. The information we supply is believed to be accurate and reliable as of this printing.
However, we assume no responsibility for its use.
While we provide application assistance personally, through our literature and the Honeywell web site, it is up to the customer
to determine the suitability of the product in the application.
Item # 1126000 M.G. 02/02 Rev. B
DIMENSIONS
xx.x = mm
MECHANICAL
Total Mechanical Travel 152 to 1219 mm
Starting Forces* 0.45 kg
Total Weight 0.36 to 2 kg
Vibration** 20 g rms/0.75 mm 5-2 Hz
Shock 50 g, 11 ms half sine
Backlash 0.025 mm
Life One Billion Dither Operations
ELECTRICAL
Theoretical 150 to 1200 mm
Electrical Travel
Independent 0.1% over
Linearity Theoretical Electrical Travel
Total Resistance 5000 Ohms
Resistance Tolerance 20%
Operating -65° to 105° C
Temperature -85° to 221° F
Resolution Infinite
Insulation Resistance 1000 M Ohms @ 500 Vdc
Dielectric Strength 1000 V rms
Recommended Wiper Current <1 µA
Electrical DIN 43650 Connector
Connection or Equivalent
Maximum Applied Voltage 30 Vdc
* Starting force for LFIIW 2.27 kg MAX
Water resistant LFIIW Models are rated to NEMA 4
** For vibration levels up to 50 g rms and higher additional housing clamps are required
Caution: Do not test on an Ohm Meter on the Rx 1 scale or other current devices.
Caution: Excessive Wiper Current can cause Output errors or damage.
Caution: Zero shaft side load is recommended to achieve maximum life.
Notes:
1. Total Mechanical Travel
equals Electrical Travel plus
2 mm minimum
2. ‘X’ equals Electrical Travel
plus 91 mm
3. ‘Y’ equals Electrical Travel
minus 25 mm
(EXCEPT for LF II 229:
‘Y’ equals Electrical Travel
minus 29 mm)
SPECIALS AND ACCESSORIES
• Other Electrical Travels
• Other Resistance Values
• Rod-end Bearings
• Ball Joint Assembly
• Dual Element
• Optional Linearity Values