1-phase filters FN 2030 General purpose EMI filter with high attenuation performance n n n n n n Rated currents from 1 to 30A High performance filter attenuation High differential-mode attenuation Optional medical versions (B type) Optional safety versions (A type) Optional overvoltage protection (Z type) Technical specifications Maximum continuous operating voltage: Operating frequency: Rated currents: High potential test voltage: Temperature range (operation and storage): Design corresponding to: Flammability corresponding to: Surge pulse protection (optional): MTBF @ 40C/230V (Mil-HB-217F): Typical electrical schematic 250VAC, 50/60Hz dc to 400Hz 1 to 30A @ 40C max. P -> E 2000VAC for 2 sec (standard types) P -> E 2500VAC for 2 sec (B types) P -> N 1100VDC for 2 sec -25C to +100C (25/100/21) UL 1283, CSA 22.2 No. 8 1986, IEC/EN 60939 UL 94V-2 or better 2kV, IEC 61000-4-5 2,200,000 hours (1 to 10A types) 1,200,000 hours (12 to 30A types) n FN 2030 filters are designed for easy and P` Cx R Cx N N` Cy PE Line Load The higher inductivity versus amperage n Electrical and electronic equipment fast chassis mounting. offers increased attenuation performance n Consumer goods The FN 2030 filters are also available as with same form factor compared to n Household equipment B versions with no Y-capacitors for medical FN 2010 and FN 2020 filter series. n Medical equipment All FN 2030 filters can be delivered with n Electronic data processing equipment optional surge pulse protection. n Office automation and datacom equipment FN 2030 filters are also available as two- n Various noisy applications requiring high applications as well as A versions with low n n capacitance for safety critical applications with a requirement for low leakage n stage filters (FN 2090 series) for very noisy currents. n L P Typical applications Features and benefits n Approvals All filters provide an exceptional conducted attenuation performance, based on chokes with high permeable core material and excellent thermal behavior. environment. n Various terminal options allow you to select the desired connection style. filter performance > Components > FN 2030 Filter selection table Filter* Rated current Leakage current** @ 40C (25C) @ 230VAC/50Hz Inductance L Capacitance Cx Cy Resistance R Input/Output connections Weight FN 2030-1-.. FN 2030-3-.. FN 2030-4-.. FN 2030-6-.. FN 2030-8-.. FN 2030-10-.. FN 2030-12-.. FN 2030-16-.. FN 2030-20-.. FN 2030-30-08 [A] 1 (1.1) 3 (3.4) 4 (4.5) 6 (6.7) 8 (8.9) 10 (11.2) 12 (13.4) 16 (17.9) 20 (22.4) 30 (33.5) [mA] 0.34 0.52 0.52 0.73 0.73 0.73 0.87 0.87 0.87 0.87 [mH] 20 14 14 8 8 8 4 4 4 2 [F] 0.22 0.33 0.33 0.47 0.47 0.47 1.0 1.0 1.0 1.0 [nF] 2.2 3.3 3.3 4.7 4.7 4.7 10 10 10 10 [k] 1000 -06 -07 1000 -06 -07 1000 -06 -07 680 -06 -07 680 -06 -07 680 -06 -07 330 -06 -07 330 -06 -07 330 -06 -08 330 -08 [g] 58 87 92 100 170 196 185 225 285 326 FN 2030A-1-.. FN 2030A-3-.. FN 2030A-4-.. FN 2030A-6-.. FN 2030A-8-.. FN 2030A-10-.. FN 2030A-12-.. FN 2030A-16-.. FN 2030A-20-.. FN 2030A-30-08 1 (1.1) 3 (3.4) 4 (4.5) 6 (6.7) 8 (8.9) 10 (11.2) 12 (13.4) 16 (17.9) 20 (22.4) 30 (33.5) 0.074 0.074 0.074 0.074 0.074 0.074 0.074 0.074 0.074 0.074 20 14 14 8 8 8 4 4 4 2 0.22 0.33 0.33 0.47 0.47 0.47 1.0 1.0 1.0 1.0 0.47 0.47 0.47 0.47 0.47 0.47 0.47 0.47 0.47 0.47 1000 -06 -07 1000 -06 -07 1000 -06 -07 680 -06 -07 680 -06 -07 680 -06 -07 330 -06 -07 330 -06 -07 330 -06 -08 330 -08 58 87 92 100 170 196 185 225 285 326 FN FN FN FN FN FN FN FN FN FN 1 (1.1) 3 (3.4) 4 (4.5) 6 (6.7) 8 (8.9) 10 (11.2) 12 (13.4) 16 (17.9) 20 (22.4) 30 (33.5) 0.002 0.002 0.002 0.002 0.002 0.002 0.002 0.002 0.002 0.002 20 14 14 8 8 8 4 4 4 2 0.22 0.33 0.33 0.47 0.47 0.47 1.0 1.0 1.0 1.0 1000 -06 -07 1000 -06 -07 1000 -06 -07 680 -06 -07 680 -06 -07 680 -06 -07 330 -06 -07 330 -06 -07 330 -06 -08 330 -08 58 87 92 100 170 196 185 225 285 326 2030B-1-.. 2030B-3-.. 2030B-4-.. 2030B-6-.. 2030B-8-.. 2030B-10-.. 2030B-12-.. 2030B-16-.. 2030B-20-.. 2030B-30-08 * To compile a complete part number, please replace the -.. with the required I/O connection style. For surge pulse protection, please add Z (e.g. FN 2030Z-10-06, FN 2030BZ-20-08). ** Maximum leakage under normal operating conditions. Note: if the neutral line is interrupted, worst case leakage could reach twice this level. Typical filter attenuation Per CISPR 17; A = 50/50 sym; B = 50/50 asym; C = 0.1/100 sym; D = 100/0.1 sym 1 to 4A types 6 to 10A types 12 to 20A types 30A types > Components > FN 2030 Mechanical data Connection style -06, 1A types Connection style -06, 8 to 20A types A F D I H B E H I K A F D N G G B E J M K M L C L Connection style -06, 3 to 6A types H I BN BN G D M BU O C K Connection style -07, 1 to 6A types (same dimensions as style -06) BN P BU GNYE J N L C Connection style -07, 8 to 16A types (same dimensions as style -06) B E A F J N Connection style -08, 20 and 30A types A F D BN I H P K BU GNYE BU G B E N J M L O C Dimensions A B C D E F G H I J K L M 1A 3A 4A 6A 8A 10A 12A 16A 20A 30A Tolerances 64 35 24.3 43.5 32.5 54 21 9.3 15.3 21.8 5.3 6.3 0.7 71 46.6 22.3 50.5 44.5 61 21 10.8 16.8 25.25 5.3 6.3 0.7 71 46.6 22.3 50.5 44.5 61 21 10.8 16.8 25.25 5.3 6.3 0.7 71 46.6 22.3 50.5 44.5 61 21 10.8 16.8 25.25 5.3 6.3 0.7 85 54 30.3 64.8 49.8 75 27 12.3 20.8 19.9 5.3 6.3 0.7 85 54 30.3 64.8 49.8 75 27 12.3 20.8 19.9 5.3 6.3 0.7 85 54 30.3 64.8 49.8 75 27 12.3 20.8 19.9 5.3 6.3 0.7 85 54 40.3 64.8 49.8 75 27 12.3 29.8 11.4 5.3 6.3 0.7 85 54 40.3 64.8 49.8 75 27 12.3 29.8 11.4 5.3 6.3 0.7 85 54 40.3 64.8 49.8 75 27 12.3 29.8 11.4 5.3 6.3 0.7 0.5 0.5 0.5 0.5 0.5 0.3 0.2 0.5 0.5 0.5 Connection style -06 N 6.3 x 0.8 6.3 x 0.8 6.3 x 0.8 6.3 x 0.8 6.3 x 0.8 6.3 x 0.8 6.3 x 0.8 6.3 x 0.8 6.3 x 0.8 Connection style -07 O 8.3 8.3 8.3 8.3 8.3 8.3 8.3 8.3 P 21.8 14 14 14 14.9 14.9 14.9 14.9 AWG type wire AWG 20 AWG 20 AWG 20 AWG 18 AWG 18 AWG 18 AWG 16 AWG 16 Wire length* 140 140 140 140 140 140 140 140 Connection style -08 N M4 M4 0.5 0.5 All dimensions in mm; 1 inch = 25.4mm Tolerances according: ISO 2768-m / EN 22768-m * Other cable length or additional wire connector on request. Your local partner: To find your local partner within Schaffner's global network, please go to www.schaffner.com October 2009