See page 30 for 8072 Mounting Panel
Blue Sea Systems
Quick Trip Circuit Breakers
PN PN
A-Series B-Series EDescription
7291 7296 Circuit Breaker 1A White
7292 7297 Circuit Breaker 2.5A White
7293 7298 Circuit Breaker 5A White
Standard Delay Circuit Breakers
PN PN
A-Series B-Series EDescription
7200 Circuit Breaker 5A Black
7201 Circuit Breaker 5A Red
7202 7275 Circuit Breaker 5A White
7203 Circuit Breaker 5A Yellow
7276 Circuit Breaker 6A White
7277 Circuit Breaker 8A White
7204 Circuit Breaker 10A Black
7205 Circuit Breaker 10A Red
7206 7278 Circuit Breaker 10A White
7207 Circuit Breaker 10A Yellow
7208 Circuit Breaker 15A Black
7209 Circuit Breaker 15A Red
7210 7279 Circuit Breaker 15A White
7211 Circuit Breaker 15A Yellow
7212 Circuit Breaker 20A Black
7213 Circuit Breaker 20A Red
7214 7280 Circuit Breaker 20A White
7215 Circuit Breaker 20A Yellow
7216 Circuit Breaker 25A Black
7217 Circuit Breaker 25A Red
7218 7281 Circuit Breaker 25A White
7219 Circuit Breaker 25A Yellow
7220 Circuit Breaker 30A Black
7221 Circuit Breaker 30A Red
7222 7282 Circuit Breaker 30A White
7223 Circuit Breaker 30A Yellow
7224 Circuit Breaker 40A Black
7225 Circuit Breaker 40A Red
7226 7283 Circuit Breaker 40A White
7227 Circuit Breaker 40A Yellow
7228 Circuit Breaker 50A Black
7229 Circuit Breaker 50A Red
7230 7284 Circuit Breaker 50A White
7231 Circuit Breaker 50A Yellow
Magnetic Circuit Breakers
Single Pole Magnetic
AC/DC Circuit Breakers
The industry standard circuit breaker for Blue Sea Systems electrical panels
Combines switching and circuit protection into a single device
B-Series circuit breakers are Emarked
Quick Trip models are designed specifically for electronics protection
Specifications
Circuit Breaker Type Magnetic
Material Phenolic
Maximum Amperage 50 Amperes
Maximum Voltage 65 Volts DC / 277 Volts AC
Rated Switch Cycles 10,000 @ rated amperage and voltage
Weight 0.17 Lb / 0.08 Kg
100%
0.01
200%
300%
400%
500%
600%
0.1 1 10 20 30 40 50 100 200 500
TRIP TIME IN SECONDS
% OF RATED CURRENT
65 Volts DC - 250 Volts AC
5 to 50 Amperes
Medium Delay
Curve No. 34
Magnetic
Circuit Breaker
100%
0.01
200%
300%
400%
500%
600%
0.1 1 10 20 30 40 50 100 200 500
TRIP TIME IN SECONDS
% OF RATED CURRENT
65 Volts DC - 277 Volts AC
5 to 50 Amperes
Short Delay
Curve No. 32
Magnetic
Circuit Breaker
A-Series
B-Series E
OFF
0.630" DIA
Panel Cutout
Detail
Ø16.00mm
2.000"
1.050"
50.80mm
26.67mm
1.050"
26.67mm
0.750"
19.05mm
#6-32 [M3] THREAD
2 PLACES
1.660"
42.16mm
0.750" 19.05mm
TYP PER POLE
0.156" DIA
Ø3.96mm
1-Pole
A & B-Series
0.170"
4.32mm
14
TRIP AREA
WORKING AREA
Quick Trip Circuit Breakers
Standard A&B Series Circuit Breakers
ASeries Single Pole 550 Amp
UL 1077 UL/CSA (US/Canada)1EN 60934 VDE (Europe)
Voltage Current
65 VDC
125 VAC
125 VAC
277 VAC
0.1 50A
0.02 30A
31 50A
0.02 30A
3000A
3000A
2000A
Fuse Backup w/o Fuse Backup
5000A 100A RK5
Fuse Backupw/o Fuse Backup
UL 1077 UL/CSA (US/Canada)1EN 60934 VDE (Europe)
Voltage Current Fuse Backup w/o Fuse Backup Fuse Backupw/o Fuse Backup
BSeries Single Pole 530 Amp
65 VDC
125 VAC
125 VAC
250 VAC
0.1 50A
0.1 30A
31 50A
0.1 30A
3000A
3000A
2000A
5000A 100A RK5
––
1500A
1500A
1500A
3000A 100A gL
3000A 63A gL
3000A 63A gL
Interrupt Ratings
Interrupt Ratings
1 UL Recognized
1 UL Recognized
See page 31 for AC Double Pole Lockout Slide
See page 30 for 8173 Mounting Panel
Magnetic Circuit Breakers
2001/2002 Marine Electrical Products 15
OFFOFF
0.630" DIA
Panel Cutout
Detail
Ø16.00mm
2.000"
50.80mm 1.050"
26.67mm
#6-32 [M3] THREAD
4 PLACES
1.660"
42.16mm
0.750 19.05mm
TYP PER POLE
0.156" DIA
Ø3.96mm
2-Pole
A & B-Series
1.500"
38.10mm
0.750"
19.05mm
1.050"
26.67mm
0.170"
4.32mm
Double Pole Magnetic
AC Circuit Breakers
The industry standard circuit breaker for Blue Sea Systems electrical panels
Used as AC main circuit breakers to switch both hot and neutral legs
With neutral circuit on one pole and hot circuit on other pole, both poles will
trip if either pole trips
Combines switching and circuit protection into a single device
B-Series circuit breakers are Emarked
Specifications
Circuit Breaker Type Magnetic
Material Phenolic
Maximum Amperage 50 Amperes
Maximum Voltage 277 Volts AC
Rated Switch Cycles 10,000 @ rated amperage and voltage
Weight 0.34 Lb / 0.16 Kg
PN PN
A-Series B-Series EDescription
7232 Circuit Breaker 10A Black
7233 Circuit Breaker 10A White
7234 Circuit Breaker 15A Black
7235 Circuit Breaker 15A White
7285 Circuit Breaker 16A White
7236 Circuit Breaker 20A Black
7260 Circuit Breaker 20A White
7237 Circuit Breaker 30A Black
7238 Circuit Breaker 30A White
7286 Circuit Breaker 32A White
7239 Circuit Breaker 40A Black
7240 Circuit Breaker 40A White
7241 Circuit Breaker 50A Black
7242 Circuit Breaker 50A White
100%
0.01
200%
300%
400%
500%
600%
0.1 1 10 20 30 40 50 100 200 500
TRIP TIME IN SECONDS
% OF RATED CURRENT
125/250 Volts AC
10 to 50 Amperes
Medium Delay
Curve No. 34
Magnetic
Circuit Breaker
A-Series
B-Series E
TRIP AREA
WORKING AREA
UL 1077 UL/CSA (US/Canada)1EN 60934 VDE (Europe)
Voltage Current Fuse Backup w/o Fuse Backup Fuse Backupw/o Fuse Backup
ASeries Double Pole 1050 Amp
UL 1077 UL/CSA (US/Canada)1EN 60934 VDE (Europe)
Voltage Current Fuse Backup w/o Fuse Backup Fuse Backupw/o Fuse Backup
65 VDC
125/250 VAC
125/250 VAC
277 VAC
0.1 50A
0.02 30A
31 50A
0.02 30A
3000A
3000A
2000A
5000A 100A RK5
BSeries Double Pole 16Amp
0.02 50A
0.1 32A
0.02 30A
31 50A
3000A
3000A
2000A
5000A 100A RK5
1500A
65 VDC
125/250 VAC
125/250 VAC
277 VAC
65 VDC
250 VAC 0.1 32A
0.02 30A
3000A
1500A
3000A 63A gL
3000A 63A gL
Interrupt Ratings
Interrupt Ratings
1 UL Recognized
1 UL Recognized