2
SCD8662 Rev G 4/24/12 Aeroflex Plainview
ABSOLUTE MAXIMUM RATINGS
PARAMETER RANGE UNITS
Input Voltage +25+VREF VDC
DC Output Current 1.5 A
Lead temperature (soldering 10 Sec) 300 °C
Input Output Differential 25 VDC
Output Voltage +25 VDC
ESD (MIL-STD-883, M3015, Class 3A) 4000 V
Operating Junction Temperature Range -55 to +150 °C
Storage Temperature Range -65 to +150 °C
NOTICE: Stresses above those listed under "Absolute Maximum Ratings" may cause permanent damage to the device. These are stress rating only;
functional operation beyond the "Operation Conditions" is not recommended and extended exposure beyond the "Operation Conditions"
may effect device reliability.
RECOMMENDED OPERATING CONDITIONS
PARAMETER RANGE UNITS
Output Voltage Range 1.275 to 23 VDC
Input Output Differential 1.5 to 25 VDC
Case Operating Temperature Range -55 to +125 °C
ELECTRICAL PERFORMANCE CHARACTERISTICS
Unless otherwise specified, -55°C < Tc < +125°C.
PARAMETER SYM CONDITIONS (P PMAX)M I N M A X U N I T S
Reference Voltage 2/ 3/VREF 10mA < IOUT < 1.0A, 1.5V < VIN - VOUT < 15V 1.210 1.275 V
Line Regulation 2/ 3/ILOAD = 10mA, Tj = +25°C,
1.5V < VIN - VOUT < 15V -0.25%
Load Regulation 2/ 3/10mA < IOUT < 1.0A, (VIN - VOUT) = 3V - 0.40 %
Dropout Voltage 2/ 4/VDROP DVREF = 1%, IOUT = 1.0A - 1.30 V
Adjust Pin Current 2/ - - - 120 µA
Adjust Pin Current Change 2/-10 mA < IOUT < 1A, 1.5V < VIN - VOUT < 15V - 5 µA
Current Limit 2/ 6/IMAX
VIN - VOUT = 5V 1.5 - A
VIN - VOUT > 25V 0.047 - A
Minimum Load Current 5/IMIN VIN - VOUT = 25V - 10 mA
Ripple Rejection 3/-
IOUT = 1.0A, (VIN - VOUT) = 3V, f = 120Hz,
CADJ = COUT = 25µF 60 - dB
Thermal Regulation - 30ms pulse, TC = +25°C - 0.04 %/W
VREF Long-Term Stability 5/ - Burn In: TC = +125°C @ 1000hrs min. Tested at +25°C only. - 0.30 %
Thermal Resistance
(Junction to Case) JC --3°C/W
Notes:
1/ For compliance with MIL-STD- 883 revision C current density specification, the RH1086MK is derated to 1 Amp but is capable of 1.5 Amps.
2/ Specification derated to reflect Total Dose exposure to 100 Krad (Si) @+25°C
3/ Line and load regulation are guaranteed up to the maximum power dissipation of 15W. Power dissipation is determined by the input/output
differential voltage and the output current. Guaranteed maximum power dissipation will not be available over the full input/output voltage range.
4/ Dropout voltage is specified over the full output current range of the device.
5/ Not tested. Shall be guaranteed by design, characterization, or correlation to other tested parameters.
6/ Pulsed @ <10% duty cycle @+25°C for characterization only. (See note 1)