SMA 50 Ohm Right Angle Crimp Type Plug Captivated Contact INCHES (MILLIMETERS) CUSTOMER DRAWINGS AVAILABLE UPON REQUEST CABLE TYPE VSWR & FREQ. RANGE GOLD PLATED NICKEL PLATED RG-161/U, 174,188, 316 LMR-100, HPF-100, RF-100 1.15 + .03 f (GHz) 0-12.4 GHz 142-0403-101 142-0403-106 CABLE GROUP RG-316/u, 161, 174, 188; LMR-100 PART NUMBER CRIMP HEX 142-0403-101 .128 (3.25) 142-0403-106 .128 (3.25) 1. Identify connector parts. (3 piece parts) 2. Strip cable to dimensions shown. Do not nick braid or center conductor. When stripping LMR-100 low loss cable, remove foil back to where cable jacket is stripped. A wire stripper of correct size is recommended for this step. Twist stranded center conductor into tight bundle and tin (optional). Slide crimp sleeve onto cable as shown. 3. Flare braid and slide cable into body making certain that the cable insulation bottoms on center contact. Solder center conductor to contact through the rear access port. Use a minimum amount of solder for a full fillet joint. .020 (0.51) diameter solder is recommended. 4. Arrange braid uniformly around crimp stem. Slide crimp sleeve over braid and crimp securely using recommended crimp tool. Place expansion cap in access port and seat with .187 (4.75) diameter flat punch. Shrink heat shrink tubing over crimp sleeve if applicable. Emerson Network Power Connectivity Solutions 299 Johnson Avenue SW, Waseca, MN 56093 * 800 -247- 8256 * +1 (507) 833-8822 * www.EmersonConnectivity.com SMA - 50 Ohm Connectors Specifications INCHES (MILLIMETERS) CUSTOMER DRAWINGS AVAILABLE UPON REQUEST ELECTRICAL RATINGS Impedance: 50 ohms Frequency Range: Dummy loads .......................................................................... 0-2 GHz Flexible cable connectors ................................................... 0-12.4 GHz Uncabled receptacles, RA semi-rigid and adapters ........... 0-18.0 GHz Straight semi-rigid cable connectors and field replaceable connectors ............................................... 0-26.5 GHz VSWR: (f = GHz) Straight Right Angle Cabled Connectors Cabled Connectors RG-178 cable .............................. 1.20 + .025f 1.20 + .03f RG-316, LMR-100 cable .............. 1.15 + .02f 1.15 + .03f RG-58, LMR-195 cable ................ 1.15 + .01f 1.15 + .02f RG-142 cable ............................... 1.15 + .01f 1.15 + .02f LMR-200, LMR-240 cable ............ 1.10 + .03f 1.10 + .06f .086 semi-rigid ............................ 1.07 + .008f 1.18 + .015f .141 semi-rigid (w/contact) .......... 1.05 + .008f 1.15 + .015f .141 semi-rigid (w/o contact) ...... 1.035 + .005f Jack-bulkhead jack adapter and plug-plug adapter ................. 1.05 + .01f Jack-jack adapter and plug-jack adapter ............................... 1.05 + .005f Uncabled receptacles, dummy loads .................................................. N/A Field replaceable (see page 59) ......................................................... N/A Working Voltage: (Vrms maximum) Connectors for Cable Type Sea Level 70K Feet RG-178 ...................................................................... 170 45 RG-316; LMR-100, 195, 200 ..................................... 250 65 RG-58, RG-142, LMR-240, .086 semi-rigid, uncabled receptacles, .141 semi-rigid w/o contact ... 335 85 .141 semi-rigid with contact and adapters ................. 500 125 Dummy loads ................................................................................. N/A Dielectric Withstanding Voltage: (VRMS minimum at sea level) Connectors for RG-178 ................................................................... 500 Connectors for RG-316; LMR-100, 195, 200 .................................. 750 Connectors for RG-58, RG-142, LMR-240, .086 semi-rigid, field replaceable, uncabled receptacles ...................................... 1000 Connectors for .141 semi-rigid with contact and adapters ............ 1500 Connectors for .141 semi-rigid w/o contact, dummy loads .............. N/A Corona Level: (Volts minimum at 70,000 feet) Connectors for RG-178 ................................................................... 125 Connectors for RG-316; LMR-100, 195, 200 .................................. 190 Connectors for RG-58, RG-142, LMR-240, 086 semi-rigid, uncabled receptacles, .141 semi-rigid w/o contact .......................... 250 Connectors for .141 semi-rigid with contact and adapters .............. 375 Dummy loads ...................................................................................... N/A Insertion Loss: (dB maximum) Straight flexible cable connectors and adapters ...................... 0.06 f (GHz), tested at 6 GHz Right angle flexible cable connectors ......................... 0.15 f (GHz), tested at 6 GHz Straight semi-rigid cable connectors with contact ..... 0.03 f (GHz), tested at 10 GHz Right angle semi-rigid cable connectors ......................... 0.05 f (GHz), tested at 10 GHz Straight semi-rigid cable connectors w/o contact ...... 0.03 f (GHz), tested at 16 GHz Straight low loss flexible cable connectors ................ 0.06 f (GHz), tested at 1 GHz Right Angle low loss flexible cable connectors ................ 0.15 f (GHz), tested at 1 GHz Uncabled receptacles, field replaceable, dummy loads ..................... N/A Insulation Resistance: 5000 megohms minimum Contact Resistance: (milliohms maximum) Initial After Environmental Center contact (straight cabled connectors and uncabled receptacles) ........................... 3.0* 4.0* Center contact (right angle cabled connectors and adapters) .............................. 4.0 6.0 Field replaceable connectors ........................ 6.0 8.0 Outer contact (all connectors) ........................... 2.0 N/A Braid to body (gold plated connectors) ............. 0.5 N/A Braid to body (nickel plated connectors) ........... 5.0 N/A *N/A where the cable center conductor is used as a contact RF Leakage: (dB minimum, tested at 2.5 GHz) Flexible cable connectors, adapters and .141 semi-rigid connectors w/o contact ............................................................. -60 dB Field replaceable w/o EMI gasket .............................................. -70 dB .086 semi-rigid connectors and .141 semi-rigid connectors with contact, and field replaceable with EMI Gasket ................ -90 dB Two-way adapters ...................................................................... -90 dB Uncabled receptacles, dummy loads .............................................. N/A RF High Potential Withstanding Voltage: (Vrms minimum, tested at 4 and 7 MHz) Connectors for RG-178 ................................................................... 335 Connectors for RG-316; LMR-100, 195, 200 .................................. 500 Connectors for RG-58, RG-142, LMR-240, .086 semi-rigid, .141 semi-rigid cable w/o contact, uncabled receptacles .............. 670 Connectors for .141 semi-rigid with contact and adapters ............ 1000 Power Rating (Dummy Load): 0.5 watt @ + 25C, derated to 0.25 watt @ +125C MECHANICAL RATINGS Engagement Design: MIL-C-39012, Series SMA Engagement/Disengagement Force: 2 inch-pounds maximum Mating Torque: 7 to 10 inch-pounds Bulkhead Mounting Nut Torque: 15 inch-pounds Coupling Proof Torque: 15 inch-pounds minimum Coupling Nut Retention: 60 pounds minimum Contact Retention: 6 lbs. minimum axial force (captivated contacts) 4 inch-ounce minimum torque (uncabled receptacles) ENVIRONMENTAL RATINGS Temperature Range: - 65C to + 165C Thermal Shock: MIL-STD-202, Method 107, Condition B Corrosion: MIL-STD-202, Method 101, Condition B Cable Retention: Axial Force*(lbs) Torque (in-oz) Connectors for RG-178 ............................ 10 N/A Connectors for RG-316, LMR-100 ........... 20 N/A Connectors for LMR-195, 200 .................. 30 N/A Connectors for RG-58, LMR-240 ............. 40 N/A Connectors for RG-142 ............................ 45 N/A Connectors for .086 semi-rigid ................. 30 16 Connectors for .141 semi-rigid ................. 60 55 *Or cable breaking strength whichever is less. Durability: 500 cycles minimum 100 cycles minimum for .141 semi-rigid connectors w/o contact (Meets or exceed the applicable paragraph of MIL-C-39012) Shock: MIL-STD-202, Method 213, Condition I Vibration: MIL-STD-202, Method 204, Condition D Moisture Resistance: MIL-STD-202, Method 106 Avoid user injury due to misapplication. See safety advisory definitions inside front cover. Emerson Network Power Connectivity Solutions 299 Johnson Avenue SW, Waseca, MN 56093 * 800 -247- 8256 * +1 (507) 833-8822 * www.EmersonConnectivity.com SMA - 50 Ohm Connectors Specifications INCHES (MILLIMETERS) CUSTOMER DRAWINGS AVAILABLE UPON REQUEST MATERIAL SPECIFICATIONS Bodies: Brass per QQ-B-626, gold plated* per MIL-G-45204 .00001" min. or nickel plated per QQ-N-290 Contacts: Male - brass per QQ-B-626, gold plated per MIL-G-45204 .00003" min. Female - beryllium copper per QQ-C-530, gold plated per MIL-G-45204 .00003" min. Nut Retention Spring: Beryllium copper per QQ-C-533. Unplated Insulators: PTFE fluorocarbon per ASTM D 1710 and ASTM D 1457 or Tefzel per ASTM D 3159 or PFA 340 per ASTM Expansion Caps: Brass per QQ-B-613, gold plated per MIL-G-45204 .00001" min. or nickel plated per QQ-N-290 Crimp Sleeves: Copper per WW-T-799 or brass per QQ-B-613, gold plated per MIL-G-45204 .00001" min. or nickel plated per QQ-N-290 Mounting Hardware: Brass per QQ-B-626 or QQ-B-613, gold plated per MIL-G-45204 .00001" min. or nickel plated per QQ-N-290 Seal Rings: Silicone rubber per ZZ-R-765 EMI Gaskets: Conductive silicone rubber per MIL-G-83528, Type M * All gold plated parts include a .00005" min. nickel underplate barrier layer. Mating Engagement for SMA Series per MIL-C-39012 JACK PLUG PLUG JACK NOTES 1. ID OF CONTACT TO MEET VSWR, CONTACT RESISTANCE AND INSERTION WITHDRAWAL FORCES WHEN MATED WITH DIA .0355-.0370 MALE PIN. Emerson Network Power Connectivity Solutions 299 Johnson Avenue SW, Waseca, MN 56093 * 800 -247- 8256 * +1 (507) 833-8822 * www.EmersonConnectivity.com