1) DCC: Discharging with constant current.
2) Requirements: ∆C/CR≤30%, ESR ≤2 times of specified limit, Ileak ≤2 times of initial value.
3) Requirements: ∆C/CR≤30%, ESR ≤2 times of specified limit, Ileak ≤2 times of initial value (1 cycle: charging to VR, 30 s rest,
discharging to VR/2, 30 s rest).
Features
Screw terminal M8 ×12
Power type
Insulated with polyurethane
Short-circuit-proof
Note
Do not put into fire!
Do not open the capacitor!
To avoid health and fire hazards, do not
operate the capacitor beyond the voltage or
temperature limits given in the data sheet.
Any excess may also result in a reduction of
lifetime.
Please pay also attention to the transport
and waste disposal instructions in chapter
"Cautions".
Dimensional drawing
Dimensions in mm
Electrical specifications
Rated capacitance (TA=25°C; DCC)1) CR1800 F
Tolerance of CR10/+30 %
Rated voltage (TA=25°C) VR2.5 V
Specific power (matched load) 10 kW/kg
Specific power (matched load) 13 kW/I
Stored energy (V = VR) E 5625 J
Specific energy (V = VR) 2.9 Wh/kg
Specific energy (V = VR) 3.9 Wh/I
Surge voltage Vsurge 2.8 V
Maximum series resistance (TA=25°C; 1 kHz) ESR 300 µΩ
Maximum series resistance (TA=25°C; 50 mHz) ESRDC 600 µΩ
Weight 540 g
Volume (without terminals) 0.40 I
Operating temperature range Top 30/+70 °C
Storage temperature (V = 0 V) Tst 40/+70 °C
Lifetime (hours)2) (TA=25°C;V=VR) 90000 h
Lifetime (cycles)3) (TA=25°C; I = 75 A) 500000 cycles
UltraCapB49410B2186Q000
Single cell, 1800 F/ 2.5 V
2