CSM_D4BL_DS_E_10_4
1
Guard Lock Safety-door Switch
D4BL
Die-cast aluminum body
Key holding force of 700 N
Auxiliary release key ensures easy maintenance and unlocks the
door in the case of a power failure.
Die-cast aluminum body incorporating a switch box with degree
of protection satisfying IP67, UL, and CSA TYPE6P, 13.
Equipped with a horizontal and vertical conduit outlet.
Models incorporating easy-to-see indicators for monitoring and
those using an adjustable Operation Key for a swinging door are
available.
The mounting direction of the head can be changed to allow the
Operation Key to be inserted from four directions.
Model Number Structure
Model Number Legend
Switch
1. Conduit Outlet (2-conduit type)
1: PG13.5
2: G1/2
4: M20
2. Built-in Switch (with Door Open/Closed Detection Switch and
Lock Monitor Switch Contacts)
C: 1NC/1NO (slow-action) + 1NC (slow-action)
D: 2NC (slow-action) + 1NC (slow-action)
3. Head Mounting Direction
R: Four mounting directions possible (right-side mounting at
shipping)
4. Door Lock and Release (Auxiliary Release Key is Incorporated
by All Models)
A: Mechanical lock/24 VDC solenoid release
G: 24 VDC Solenoid lock/Mechanical release
5. Indicator
Blank: Without indicator
A: 10 to 115 VAC or VDC driving (with orange and green LED
indicator unit)
Operation Key
1. Operation Key Type
1: Horizontal mounting
2: Vertical mounting
3: Adjustable mounting (Horizontal)
For the most recent information on models that have been certified
for safety standards, refer to your OMRON website.
Be sure to read the “Safety Precautions” on page 11.
1234 5
D4BL - -
1
D4BL - K
D4BL
2
Switch
1. Conduit Outlet (2-conduit type)
2: G1/2
2. Built-in Switch
G: 2NC (slow-action) + 2NC (slow-action)
3. Head Mounting Direction
R: Four mounting directions possible (right-side mounting at
shipping)
4. Door Lock and Release
D: Mechanical lock/24 VDC solenoid release
5. Indicator lamp
A: Equipped with an orange/green LED display unit
Operation Key
1. Operation Key Type
1: Horizontal mounting
2: Vertical mounting
3: Adjustable mounting (Horizontal)
Ordering Information
List of Models
Switches (Operation Keys are sold separately.)
Consult with your OMRON representative when ordering any models that are not listed in this table.
Operation Keys
2 1 4 3 5
D4BL -2GRD-AT
1
D4BL - K
Lock
method Conduit
outlet
Voltage
for
solenoid
Without indicator
1NC/1NO+ 1NC
(Slow-action)
With LED indicator
1NC/1NO+ 1NC
(Slow-action)
Without indicator
2NC+ 1NC
(Slow-action)
With LED indicator
2NC+ 1NC
(Slow-action)
Mechanical
lock
PG13.5
24 VDC
D4BL-1CRA D4BL-1CRA-A D4BL-1DRA D4BL-1DRA-A
G1/2 D4BL-2CRA D4BL-2CRA-A D4BL-2DRA D4BL-2DRA-A
M20 D4BL-4CRA D4BL-4CRA-A D4BL-4DRA D4BL-4DRA-A
Solenoid
lock
Pg 13.5
24 VDC
D4BL-1CRG D4BL-1CRG-A D4BL-1DRG D4BL-1DRG-A
G1/2 D4BL-2CRG D4BL-2CRG-A D4BL-2DRG D4BL-2DRG-A
M20
D4BL-4CRG D4BL-4CRG-A D4BL-4DRG D4BL-4DRG-A
Lock
method Conduit
outlet
Voltage
for
solenoid
With LED indicator
2NC+ 2NC
(Slow-action)
Mechanical
lock G1/2 24 VDC D4BL-2GRD-AT
Mounting type Model
Horizontal mounting D4BL-K1
Vertical mounting D4BL-K2
Adjustable mounting D4BL-K3
3
D4BL
Specifications
Standards and EC Directives
Conforms to the following EC Directives:
Machinery Directive
EN ISO 14119
EN 60204-1
Certified Standards
Certified Standard Ratings
TÜV (EN60947-5-1), CCC (GB/T 14048.5)
Note: Use a 10 A fuse type gI or gG that conforms to IEC60269 as a short-circuit protection device.
UL/CSA (UL508, CSA C22.2 No. 14)
A300
Note: The UL/CSA certified rating for products with indicators (-A) is 6 A/115 VAC.
Certification body Standard File No.
TÜV Rheinland
EN60947-5-1
(certified direct
opening)
GS-ET-19
Consult your OMRON
representative for details.
UL UL508 E76675
CSA CSA C22.2, No.14 LR45746
CQC (CCC) GB/T 14048.5 Consult your OMRON
representative for details.
Item Type Standard model Indicator model
Utilization category AC-15 AC-15
Rated operating current (Ie)3 A 6 A
Rated operating voltage (Ue)250 V 115 V
Rated voltage Carry current Current (A) Volt-amperes (VA)
Make Break Make Break
120 VAC 10 A 60 6 7,200 720
240 VAC 30 3
D4BL
4
Characteristics
Note: The above values are initial values.
*1. The degree of protection is tested using the method specified by the standard (EN60947-5-1). Confirm that sealing properties are sufficient for
the operating conditions and environment beforehand. Although the switch box is protected from dust, oil or water penetration, do not use the
D4BL in places where dust, oil, water, or chemicals may enter through the key hole on the head, otherwise Switch damage or malfunctioning
may occur.
*2. The durability is for an ambient temperature of 5 to 35°C and an ambient humidity of 40% to 70%.
*3. These figures are minimum requirements for safe operation.
Solenoid Coil Characteristics
Indicator Characteristics
Interlock type Type 2 (EN ISO 14119)
Coding level Low Level coded (EN ISO 14119)
Degree of protection *1IP67 (EN60947-5-1)
Durability *2Mechanical 1,000,000 operations min.
Electrical 500,000 operations min. (10 A resistive load at 250 VAC)
Operating speed 0.05 to 0.5 m/s
Operating frequency 30 operations/minute max.
Direct opening force *319.61 N min. (EN60947-5-1)
Direct opening travel *320 mm min. (EN60947-5-1)
Holding force (Fzh) 700 N min. (GS-ET-19)
Contact resistance 50 mΩ max.
Rated insulation voltage (Ui)300 V (EN60947-5-1)
Rated frequency 50/60 Hz
Protection against electric shock Class I (with ground terminal)
Pollution degree (operating environment) 3 (EN60947-5-1)
Impulse withstand
voltage (Uimp)
(EN60947-5-1)
Between terminals
of same polarity
4 kV
Between terminals
of different polarity
Between each
terminal and
ground
Between solenoid
and ground 2.5 kV
Insulation resistance 100 MΩ min. (at 500 VDC)
Contact gap 2 × 2 mm min.
Vibration resistance Malfunction 10 to 55 Hz, 0.35 mm single amplitude
Shock resistance Destruction 1,000 m/s2 min.
Malfunction 300 m/s2 min.
Conditional short-circuit current 100 A (EN60947-5-1)
Conventional enclosed thermal current (I
the
)
10 A (EN60947-5-1)
Ambient operating temperature –10 to 55°C (with no icing)
Ambient operating humidity 95% max.
Weight Approx. 800 g
Item Type 24 VDC mechanical lock models 24 VDC solenoid lock models
Rated operating voltage 24 VDC (100% ED)
Current consumption Approx. 300 mA
Insulation class Class B (130°C or less)
+10%
15%
Rated voltage 10 to 115 VAC/VDC
Current leakage Approx. 1 mA
Color (LED) Orange, green
5
D4BL
Structure and Nomenclature
Structure
Model and Contact Configuration (Diagrams Show State with Key Inserted and Lock Engaged)
Note: The EN-certified direct opening mechanism is indicated by on the Switch.
Contact Form (D4BL-2GRD-AT)
Model
Contact
(door open/
closed detection
and lock monitor)
Contact form
Operating pattern Remarks
Lock monitor Door open/
closed detection
D4BL-@CR@-@
1NC/1NO+1NC
D4BL-@DR@-@2NC+1NC
D4BL-@CR@-@D4BL-@DR@-@
Operation Key
Lock plate
Rotating drum
Operation plunger
Seal ring (NBR)
Auxiliary plunger
Seal packing (NBR)
Rotating lever
Safety switch
Seal packing (NBR)
Ground terminal M3.5
Solenoid
Lock monitor switch
Auxiliary release key
Operation Key
Lock plate
Rotating drum
Operation plunger
Seal ring (NBR)
Auxiliary plunger
Seal packing (NBR)
Rotating lever
Safety switch
Seal packing (NBR)
Ground terminal M3.5
Solenoid
Lock monitor switch
Auxiliary release key
Conduit outlet
(Pull out
horizontally)
Connection
terminal M3.5
Conduit outlet
(Pull out
vertically)
Conduit outlet
(Pull out
horizontally)
Connection
terminal M3.5
Conduit outlet
(Pull out
vertically)
The head can be changed
to any of four directions.
31 32 11 12
24
23
Door
open/closed detection
Lock monitor
Operation Key
insertion completion
position
Extraction
completion
position
ON
Stroke
31-12
23-24
Lock position
12
22
11 32 31
21
Door
open/closed detection
Lock monitor
Operation Key
insertion completion
position
Extraction
completion
position
ON
31-12
21-22
Lock position
Stroke
Only NC contacts
11-12 and 21-22
have a certified
direct opening
mechanism.
The terminals 11-12
and 21-22 can be
used as unlike poles.
31 32 11 12 (Safety circuit side)
41 42 21 22 (Monitor circuit side)
D4BL
6
Dimensions and Operating Characteristics (Unit: mm)
Switches
Note: 1. Unless otherwise specified, a tolerance of ±0.4 mm applies to all dimensions.
2. There are fluctuations in the contact ON/OFF timing for 2NC contacts. Confirm performance before application.
100±0.1
74±0.1
112
+1
0
86
+1
0
34.2
(123.5)
6.8
(116.5)
10
15
5.5
7 37.5
31.5
17
16
39.6
46.3
Conduit outlet
Indicators
Conduit outlet
Cover
D4BL-@@R@-@
Red
Four, M3.5 head
clamping screws
Lock
protection
cap
Four, 5.3 dia.
mounting
holes
Four, M4
cover
clamping
screws
Operating
Characteristics
Model D4BL-@@R@-@
Key insertion force
Key extraction force
19.61 N max.
19.61 N max.
Pre-travel distance 15 mm max.
Movement before being locked
4 mm min.
31.5
17
7 37.5
86
+1
0
112+1
0
16
39.6
42.6
Conduit outlet
Conduit outlet
Indictor
(Orange: Switch OFF)
Indicator
(Green:
Solenoid ON).
5.5
Conduit outlet
(116.5) 10
34.2
74±0.1
100±0.1
6.8
(123.5)
Cover
Four, 5.3 dia.
Mounting
holes
Four, M3.5 head
clamping screws
Four, M4
cover
clamping
screws
Operating
Characteristics
Model D4BL-2GRD-AT
Key insertion force
Key extraction force
19.61 N max.
19.61 N max.
Pre-travel distance 15 mm max.
Movement before being locked
4 mm min.
D4BL-2GRD-AT
Red
7
D4BL
Operation Keys
78.7 20
12
40.7
25.8 15.6 7.3 15
5.3 5.3
36
11.8
5.6
2.6 7.5
20
4 dia.
Two, 2.65R
Long mounting hole
D4BL-K1 Red
36
11.8
(37.8)
19.5
2.6
17.5
34.6
(80.7)
40
30
30 5.6
26
18
°
18
°
15.6
12
420
40
M4 Allen-head bolt
5.3 dia.
4 dia.
D4BL-K3 Red
Red
53.7 13
40 52.4
15.6
25.8
11.8
5.6
36
2.6
5.3 11.9 7.5
20
5.3 x 7.3 long mounting hole
4 dia.
D4BL-K2
Red
D4BL
8
With Operation Key Inserted
Note: 1. Unless otherwise specified, a tolerance of ±0.4 mm applies to all dimensions.
2. In the above diagrams, the Operation Key is inserted from the front.
*1. The insertion radii apply when the rotational center of the Operation Key in on surface A in the figures.
*2. The insertion radii apply when the rotational center of the Operation Key in on the Operation Key installation surface.
(20±0.15)
(20±0.15)
(35)
(41)
(41) (12)
53.5 min. 57 max.
53.5 min. 57 max.
Horizontal direction
Operation Key
insertion radius
R 1200 *1
Vertical direction
Operation Key
insertion radius
R 1000 *1
Surface A
D4BL + D4BL-K1
Red
(41) (13)
(40±0.15)
(41)
(35)
54.5 min. 58 max.
54.5 min. 58 max.
Horizontal direction
Operation Key
insertion radius
R 1200 *2
Vertical direction
Operation Key
insertion radius
R 1000 *2
D4BL + D4BL-K2
Red
(30±0.15)
(41) (40)
(35)
(41)
81.5 min. 85 max.
81.5 min. 85 max.
Horizontal direction
Operation Key
insertion radius
R 250 *2
Vertical direction
Operation Key
insertion radius
R 1000 *2
D4BL + D4BL-K3
Red
9
D4BL
Indicator Unit
Connections
Internal Circuit Diagram
Indicator Solenoid
(16)
(16)
(7)
(35) 26.2
(61.2)
0.3
5.6
26.8 53.2 57.2
2 10.6
(12.6)
Two, 7 dia.
Four terminal plates
Two LED
LED
10 to 115 VAC/VDC
Constant-current diode
R
ZDR
E1 (+)
24 VDC
E2 ()
D4BL
10
Circuit Connection Example
Terminals 11 and 32 are connected internally.
When using indicators, connect them to the auxiliary circuit side (monitor circuit) or in parallel between E1 and E2 as shown below.
Do not connect the indicators in parallel with the direct opening contact. If the indicators are broken, a short-circuit current may flow, causing
equipment to malfunction.
The 24 VDC solenoid terminals have polarity. Confirm the polarity before wiring.
1112 31
E2 ()
E1 (+)
32
23 24
1112 31
E2 ()
E1 (+)
32
23 24
1112 31
E2 ()
E1 (+)
32
21 22
1112 31
E2 ()
E1 (+)
32
2221
1. Orange: Lights when the solenoid turns ON.
Green: Lights when the door opens.
(Power supply side)
Solenoid
LED (orange)
LED (green)
Auxiliary circuit
(monitor circuit) Safety circuit
2. Orange: Lights when the solenoid turns ON.
Green: Lights when power turns ON.
(Power supply side)
Solenoid
LED (orange)
LED (green)
Auxiliary circuit
(monitor circuit) Safety circuit
3. Orange: Lights when the solenoid turns ON.
Green: Lights when door closes.
(Power supply side)
Solenoid
LED (orange)
LED (green)
Auxiliary circuit
(monitor circuit) Safety circuit
4. Orange: Lights when the solenoid turns ON.
Green: Lights when power turns ON.
(Power supply side)
Solenoid
LED (orange)
LED (green)
Auxiliary circuit
(monitor circuit) Safety circuit
D4BL
11
Safety Precautions
Be sure to read the precautions for All Safety Door Switches in the website at: http://www.ia.omron.com/.
Do not use the Switch submersed in oil or water or in locations
continuously subject to splashes of oil or water. Doing so may
result in oil or water entering the Switch. (The IP67 degree of
protection of the Switch specifies the amount of water penetration
after the Switch is submerged in water for a certain period of time.)
Always attach the cover after completing wiring and before using
the Switch. Also, do not turn ON the Switch with the cover open.
Doing so may result in electric shock.
Make sure the Switch is mounted securely to prevent it from falling
off. Otherwise injury may result.
Stopper Installation
Do not use a Switch as a stopper. Be sure to install a stopper as
shown in the following illustration when mounting the Switch so that
the Operation Key is within 0.5 to 5 mm of the set zone.
Do not subject the Switch to a shock that exceeds the Switch's shock
resistance of 1,000 m/s2.
Appropriate Tightening Torque
Loose screws may result in malfunction.
Be sure to tighten each screw of the Switch properly.
*Use M5 screws. Apply a torque of 4.90 to 5.88 N·m for an
Allen-head bolt. For a pan head screw, apply a torque of 2.35 to
2.75 N·m
Auxiliary Release Key
The auxiliary release key is used to unlock the D4BL in case of
emergency or in case the power supply to the D4BL fails.
Use the enclosed Release Key to change the lock from LOCK to
UNLOCK so that the lock will be released and the door can be
opened. (Applies only to mechanical locks. Release key is not
provided with D4BL-2GRD-AT.)
When a Switch with a solenoid lock is in a locked state (i.e., when
the solenoid is ON), do not change the release key from the LOCK
to the UNLOCK position. Internal parts may be damaged.
Whenever the lock has been changed to UNLOCK, always return
it to LOCK before using the Switch.
Do not use the auxiliary release key to start or stop machines.
Make sure that the auxiliary release key is kept with the person in
charge.
To prevent the release key from being used by unauthorized
personnel, set it to LOCK and seal the provided seal cap with
sealing wax to ensure IP67.
Before attaching the cover to the D4BL, make sure that the
auxiliary release key position is set to LOCK.
Injury may occasionally occur. Always check to make
sure that the safety functions operate correctly before
using the machine. The safety functions may not operate
correctly because of wiring mistakes, setting mistakes,
or Switch malfunction, causing some machines to
continue operating in situations where they should be
stopped.
Injury may occasionally occur. If the machine is used
with the release key in the UNLOCK position, the
electromagnetic lock may not operate, causing some
machines to continue operating in situations where they
should be stopped. Be sure to put the release key in the
LOCK position before using the machine. Also, check
the condition of the lock and safety circuits.
Injury may occasionally occur. When the
electromagnetic lock function or Switch function is
damaged, some machines may continue operating in
situations where they should be stopped. Do not use the
electromagnetic lock function of the Switch in place of a
door lock. Always provide a lock separate from the
Switch, attach a warning seal to prevent people from
using excessive force to open the door when it is locked,
or provide an indicator lamp to show the locked/unlocked
status of the door.
Precautions for Safe Use
DANGER
Switch
Stopper
Incorrect
Correct
Gap
Set zone
Correct
Incorrect
Precautions for Correct Use
No. Type Appropriate
tightening
torque
1M3.5 terminal screw
(including terminal screw) 0.59 to 0.78 N·m
2 Cover mounting screw 1.18 to 1.37 N·m
3 Head mounting screw 0.78 to 0.98 N·m
4 M5 body mounting screw *4.90 to 5.88 N·m
5 Operation Key mounting screw 2.35 to 2.75 N·m
6 Cable gland 1.77 to 2.16 N·m
7 Conduit cap screw 1.27 to 1.67 N·m
5. Two, M5 Operation Key mounting screw
3. Four, M3.5 head-mounting screw
6. Cable gland 7. Conduit cap screw
2. Four, M4 cover-mounting
screw
4. Four, M5
switch-mounting screw
UNLOCK
LOCK
Auxiliary
release key
12
D4BL
Solenoid Lock Models
The solenoid lock locks the door only when power is supplied to the
solenoid. Therefore, the door will be unlocked if the power supply to
the solenoid stops. Therefore, do not use solenoid lock models for
machines that may be operating and dangerous even after the
machine stops operating.
Switch and Operation Key Mounting
Use four M5 screws and spring washers to mount the Switch and
Operation Key, and tighten the screws to a suitable torque.
To ensure safety, use screws that cannot be easily removed or
another means to prevent the Switch and Operation Key from easily
being removed.
Mounting Dimensions
Switch Mounting Dimensions
Operation Key Mounting Holes
D4BL-K1
D4BL-K2
D4BL-K3
Operation Key
The D4BL is provided with a shock-absorbing damper to protect
the D4BL from damage that may result from dropping the D4BL
during transportation. Be sure to remove the damper after
mounting the D4BL.
The mounting tolerance of the Operation Key is ±0.3 mm vertically
or horizontally. Be sure to mount the D4BL correctly without
misalignment, otherwise the D4BL may soon break or wear out.
Observe the specified insertion radius for the Operation Key and
insert it in a direction perpendicular to the key hole.
Do not use the D4BS operation key.
Use only the designated Operation Key. The Head has been
designed so that operation is not possible with a screwdriver or
other tools. Using anything other than the designated Operation
Key may damage the Switch or affect machine safety.
Do not operate the Switch with anything other than the special
OMRON Operation Key, otherwise the Switch may break or the
safety of the system may not be maintained.
Do not impose excessive force on the Operation Key while the Key
is inserted into the Switch or drop the Switch with the Operation
Key inserted. Doing either of these may deform the Key or break
the Switch.
Head Direction
The head can be mounted in four directions by loosening the four
screws holding the head. To remove the head, turn the head at the
surface mating with the Switch body by 45° as shown in figures (A)
and (B) below.
To change the direction of the head, make sure that the protruding
part of the rotating lever engages with the groove of the plunger.
Then turn the head clockwise or counterclockwise to the desired
direction. At that time, make sure that the groove of the plunger is
located under the rotating lever. If the direction of the head is not
set when the plunger is rotated by 45°, the groove of the plunger
presses the rotating lever. The head, plunger, or the built-in switch
may be damaged as a result.
Head Direction Changes
Be sure to check the mechanical lock and solenoid release
functions when mounting the D4BL.
If the head direction is changed, recheck the tightening torque of
each of screw. Make sure that no foreign materials will enter
through the key hole on the head.
100±0.1
74±0.1
Four, M5
20±0.1
Two, M5
40±0.1
Two, M5
30±0.1
Two, M5
Greater
than ±0.3
Greater
than ±0.3
Incorrect
Incorrect
(A) (B)
(45°)
(45°)
Left
Front
Back
Right
Head Bottom View Switch Top View
Operation plunger and
groove mechanism
Rotation lever and
protruding part
Switch body
Plunger (with groove)
Built-in switch
Normal Positions of Rotating Lever and Plunger
Rotating lever (with
protruding part)
D4BL
13
Processing and Connecting Cable/
Conduit Outlet
The following procedures are recommended for mounting and
wiring the indicator unit securely.
To ensure IP67, use OMRON’s SC-@M and Nippon Flex’s
ABS-08Pg13.5 and ABS-12 Pg13.5 Connectors.
Recommended cable: UL2464-type cable that is AWG20 to
AWG18 (0.5 to 1.0 mm2) in size and has seven conductors
Connect the indicator unit after connecting the seven-conductor
cable.
Properly attach and securely tighten the provided conduit cap
screw to the unused conduit outlet to the suitable tightening torque
when wiring the D4BL.
Cable Connection Example
1. Connect the wires to the terminals in the order shown below for
wiring efficiency.
Tighten each wired terminal clockwise to a torque of 0.59 to
0.78 N·m.
Twist the wire two or three times and make sure that no bare wire
exists outside the terminal when tightening the terminal.
2. The insulation sheath of the seven-conductor cable must come into
contact with the wall of the conduit mouth, side A or side B.
Others
Do not touch the solenoid because the solenoid radiates heat while
power is being supplied.
Terminal no. Lp (mm) Lv (mm) a (mm)
E130±280±2
8±1
E235±275±2
31 45±260±2
12 55±250±2
23 (21) 65±245±2
24 (22) 70±235±2
90±250±2
Insulation sheath edge
Terms and Conditions Agreement
Read and understand this catalog.
Please read and understand this catalog before purchasing the products. Please consult your OMRON representative if you
have any questions or comments.
Warranties.
(a) Exclusive Warranty. Omrons exclusive warranty is that the Products will be free from defects in materials and workmanship
for a period of twelve months from the date of sale by Omron (or such other period expressed in writing by Omron). Omron
disclaims all other warranties, express or implied.
(b) Limitations. OMRON MAKES NO WARRANTY OR REPRESENTATION, EXPRESS OR IMPLIED, ABOUT
NON-INFRINGEMENT, MERCHANTABILITY OR FITNESS FOR A PARTICULAR PURPOSE OF THE PRODUCTS. BUYER
ACKNOWLEDGES THAT IT ALONE HAS DETERMINED THAT THE
PRODUCTS WILL SUITABLY MEET THE REQUIREMENTS OF THEIR INTENDED USE.
Omron further disclaims all warranties and responsibility of any type for claims or expenses based on infringement by the
Products or otherwise of any intellectual property right. (c) Buyer Remedy. Omrons sole obligation hereunder shall be, at
Omrons election, to (i) replace (in the form originally shipped with Buyer responsible for labor charges for removal or
replacement thereof) the non-complying Product, (ii) repair the non-complying Product, or (iii) repay or credit Buyer an amount
equal to the purchase price of the non-complying Product; provided that in no event shall Omron be responsible for warranty,
repair, indemnity or any other claims or expenses regarding the Products unless Omrons analysis confirms that the Products
were properly handled, stored, installed and maintained and not subject to contamination, abuse, misuse or inappropriate
modification. Return of any Products by Buyer must be approved in writing by Omron before shipment. Omron Companies shall
not be liable for the suitability or unsuitability or the results from the use of Products in combination with any electrical or
electronic components, circuits, system assemblies or any other materials or substances or environments. Any advice,
recommendations or information given orally or in writing, are not to be construed as an amendment or addition to the above
warranty.
See http://www.omron.com/global/ or contact your Omron representative for published information.
Limitation on Liability; Etc.
OMRON COMPANIES SHALL NOT BE LIABLE FOR SPECIAL, INDIRECT, INCIDENTAL, OR CONSEQUENTIAL DAMAGES,
LOSS OF PROFITS OR PRODUCTION OR COMMERCIAL LOSS IN ANY WAY CONNECTED WITH THE PRODUCTS,
WHETHER SUCH CLAIM IS BASED IN CONTRACT, WARRANTY, NEGLIGENCE OR STRICT LIABILITY.
Further, in no event shall liability of Omron Companies exceed the individual price of the Product on which liability is asserted.
Suitability of Use.
Omron Companies shall not be responsible for conformity with any standards, codes or regulations which apply to the
combination of the Product in the Buyers application or use of the Product. At Buyers request, Omron will provide applicable
third party certification documents identifying ratings and limitations of use which apply to the Product. This information by itself
is not sufficient for a complete determination of the suitability of the Product in combination with the end product, machine,
system, or other application or use. Buyer shall be solely responsible for determining appropriateness of the particular Product
with respect to Buyers application, product or system. Buyer shall take application responsibility in all cases.
NEVER USE THE PRODUCT FOR AN APPLICATION INVOLVING SERIOUS RISK TO LIFE OR PROPERTY OR IN LARGE
QUANTITIES WITHOUT ENSURING THAT THE SYSTEM AS A WHOLE HAS BEEN DESIGNED TO ADDRESS THE RISKS,
AND THAT THE OMRON PRODUCT(S) IS PROPERLY RATED AND INSTALLED FOR THE INTENDED USE WITHIN THE
OVERALL EQUIPMENT OR SYSTEM.
Programmable Products.
Omron Companies shall not be responsible for the users programming of a programmable Product, or any consequence
thereof.
Performance Data.
Data presented in Omron Company websites, catalogs and other materials is provided as a guide for the user in determining
suitability and does not constitute a warranty. It may represent the result of Omrons test conditions, and the user must correlate
it to actual application requirements. Actual performance is subject to the Omrons Warranty and Limitations of Liability.
Change in Specifications.
Product specifications and accessories may be changed at any time based on improvements and other reasons. It is our
practice to change part numbers when published ratings or features are changed, or when significant construction changes are
made. However, some specifications of the Product may be changed without any notice. When in doubt, special part numbers
may be assigned to fix or establish key specifications for your application. Please consult with your Omrons representative at
any time to confirm actual specifications of purchased Product.
Errors and Omissions.
Information presented by Omron Companies has been checked and is believed to be accurate; however, no responsibility is
assumed for clerical, typographical or proofreading errors or omissions.
2018.10
In the interest of product improvement, specifications are subject to change without notice.
OMRON Corporation
Industrial Automation Company
http://www.ia.omron.com/ (c)Copyright OMRON Corporation 2018 All Right Reserved.