Page 1
3863X Series
Single Color φ3 Flush Mount Round Shape Type
Recommended Applications
Amusement Equipment, Electric Household Appliances, OA/FA, Other General Applications
Outer Dimension φ3 Flush Mount Round shape type
Operation temperature range.
Storage Temperature :-40℃~100
Operati ng Tem p erat ure :-40℃~85
Lead–free soldering compatible
RoHS compliant
Dominant wavelength Yellow Green : 572nm (YPY)
Yellow : 590nm (FY)
Orange : 605nm (FA)
Red : 626nm (FR)
Product features
Half Intensity Angle
Die materi als YPY,FY,FA,FR : AlGaInP
YPY,FY,FA,FR : 20 deg.
Features
Package Φ3 Round shape type,
YPY,FY : Pale Yellow Clear epoxy
FA : Pale Orange Clear epoxy
FR : Pale Red Clear epoxy
Rank grou pi n g p ar am et er
Soldering methods
ESD
Packing
TTW (Through The Wave) soldering and manual soldering
AlGaInP : More than 2kV(HBM)
Bulk : 200pcs(MIN.)
Sorted by luminous intensity per rank taping
2008.11.27
Color and Luminous Intensity
Page 2
TYP. I
F
M I N. TYP. I
F
YPY3863X AlGaInP Ye llow Gree n 572 20 180 360 20
FY3863X AlGaInP Yellow 590 20 360 720 20
FA3863X AlGaInP Orange Pale
Orange 605 20 400 800 20
FR3863X AlGaInP Red Pale
Red 626 20 320 640 20
Iv ( mcd)
Luminous Intensity
Dominant
Wavelength
λd (nm)
Palle
Yellow
P art No. Material Emitted
Color Lens
Color
Clear
Single Col or φ3 Flush Mount Round Shape Type
3863X Series
(Ta=25)
2005.7.29
Page 3
Absolute Maximum Ratings
YPY FY FA FR
Power D issipation P
d
130 125 125 125 mW
For ward Cur rent I
F
50 50 50 50 mA
Pulse Forwar d
Cur r e nt
1
I
FRM
200 200 200 200 mA
Deratin
g
(
Ta=25 or hi
g
her
)
I
F
0.67 0.67 0.67 0.67 mA/
Reverse Voltage V
R
5555V
Operatin
g
Tem
p
erature T
opr
Storage Temperatur e T
stg
Absolut e Ma ximum Ra t ings
-40+85
-40+100
Item Symbol Unit
2005.7.29
Single Col or φ3 Flush Mount Round Shape Type
3863X Series
1 IFRM Measurement condition : Pulse Width1ms., Duty1/20.
(Ta=25)
Electro-Optical Characteristics
Page 4
2005.7.29
Single Col or φ3 Flush Mount Round Shape Type
3863X Series
Conditions YPY FY FA FR
TYP. 2.1 1.9 1.9 1.9
MAX. 2.5 2.4 2.4 2.4
Reverse Current V
R
=5V I
R
MAX. 100 100 100 100 μA
Peak Wav elen gth I
F
=20mA λ
p
TYP. 575 592 609 635 nm
Dominant
Wavelength I
F
=20mA λ
d
TYP. 572 590 605 626 nm
Spectr al Line Half
Width I
F
=20mA ⊿λ TYP. 15 15 15 15 nm
Half Intensity Angle I
F
=20mA 2θ1/2TYP.20202020deg.
Item Symbol Unit
Forw ard Voltage I
F
=20mA V
F
V
Characteristics
(Ta=25)
Luminous Intensity Rank
Page 5
Please contact our sales staff concerning rank designation.
2005.7.29
Single Col or φ3 Flush Mount Round Shape Type
3863X Series
(Ta=25)
MIN. MAX. MIN. MAX. MIN. MAX. MIN. MAX.
A
180 360 360 720 400 800 320 640
B
250 500 500 1,000 560 1,120 450 900
C
360 780 720 1,440 800 1,600 640 1,280
D
500 1,000 1,000 2,000 1,120 2,240 900 1,800
E
780 - 1,440 - 1,600 - 1,280 -
I
F
= 20 mA
Condition
I
V
mcd
Rank
FRYPY FY FA
Page 6
2005.7.29
Single Col or φ3 Flush Mount Round Shape Type
3863X Series
Spatial Distri bution Example
Condition : Ta = 25
Spectral Distribution
Relative Intensity vs. Wavelength
Condition : Ta = 25, IF= 20mA
Wavelength [nm]
Relative Intensity
Forward Voltage vs. Forward Current
Condition : Ta = 25
Forward Voltage VF(V)
Forward Current IF(mA)
Forward Current vs. Relative Intensity
Condition : Ta = 25
Forward Current IF(mA)
Relative Intensity
Technical Data(YPY)
Power Dissipation vs. Ambient Temperature
Ambient Temperature : Ta()
Page 7
2005.7.29
Single Col or φ3 Flush Mount Round Shape Type
3863X Series
Ambient Temperature vs. Relativ e Intensity
Condition : IF=20mA
Ambient Temperature : Ta()
Derating
Ambient Temperature vs. Maximum Forward Current
Repetition Frequency : f 50Hz
Ambient Temperature : Ta()
Maximum Forward Current : IFMAX. (mA)
Relative Intensity
Technical Data(YPY)
Ambient Temperature vs. Forward Voltage
Ambient Temperature : Ta()
Forward Voltage VF(V)
Power Dissipation : Pd (mW)
Page 8
2005.7.29
Single Col or φ3 Flush Mount Round Shape Type
3863X Series
Technical Data(YPY)
Pulse Width vs. Maximum Tolerable Peak Current
Condition : Ta = 25
Pulse Width : tw (μs)
Dynamic Drive Rating
Duty cycle vs. Maximum Forward Current
Condition : Ta = 25
Duty (%)
Maximum Forward Current : IF MAX. (mA)
IFpeak Max./IFDC MAX.
Page 9
2005.7.29
Single Col or φ3 Flush Mount Round Shape Type
3863X Series
Spatial Distri bution Example
Condition : Ta = 25
Spectral Distribution
Relative Intensity vs. Wavelength
Condition : Ta = 25, IF= 20mA
Wavelength [nm]
Relative Intensity
Forward Voltage vs. Forward Current
Condition : Ta = 25
Forward Voltage VF(V)
Forward Current IF(mA)
Forward Current vs. Relative Intensity
Condition : Ta = 25
Forward Current IF(mA)
Relative Intensity
Technical Data(FY)
Ambient Temperature vs. Relativ e Intensity
Condition : IF=20mA
Ambient Temperature : Ta()
Page 10
2005.7.29
Single Col or φ3 Flush Mount Round Shape Type
3863X Series
Derating
Ambient Temperature vs. Maximum Forward Current
Repetition Frequency : f 50Hz
Ambient Temperature : Ta()
Maximum Forward Current : IFMAX. (mA)
Relative Intensity
Technical Data(FY)
Ambient Temperature vs. Forward Voltage
Ambient Temperature : Ta()
Forward Voltage VF(V)
Power Dissipation vs. Ambient Temperature
Ambient Temperature : Ta()
Power Dissipation : Pd (mW)
Page 11
2005.7.29
Single Col or φ3 Flush Mount Round Shape Type
3863X Series
Technical Data(FY)
Pulse Width vs. Maximum Tolerable Peak Current
Condition : Ta = 25
Pulse Width : tw (μs)
Dynamic Drive Rating
Duty cycle vs. Maximum Forward Current
Condition : Ta = 25
Duty (%)
Maximum Forward Current : IF MAX. (mA)
IFpeak Max./IFDC MAX.
Page 12
2005.7.29
Single Col or φ3 Flush Mount Round Shape Type
3863X Series
Spatial Distri bution Example
Condition : Ta = 25
Spectral Distribution
Relative Intensity vs. Wavelength
Condition : Ta = 25, IF= 20mA
Wavelength [nm]
Relative Intensity
Forward Voltage vs. Forward Current
Condition : Ta = 25
Forward Voltage VF(V)
Forward Current IF(mA)
Forward Current vs. Relative Intensity
Condition : Ta = 25
Forward Current IF(mA)
Relative Intensity
Technical Data(FA)
Ambient Temperature vs. Relativ e Intensity
Condition : IF=20mA
Ambient Temperature : Ta()
Page 13
2005.7.29
Single Col or φ3 Flush Mount Round Shape Type
3863X Series
Derating
Ambient Temperature vs. Maximum Forward Current
Repetition Frequency : f 50Hz
Ambient Temperature : Ta()
Maximum Forward Current : IFMAX. (mA)
Relative Intensity
Technical Data(FA)
Ambient Temperature vs. Forward Voltage
Ambient Temperature : Ta()
Forward Voltage VF(V)
Power Dissipation vs. Ambient Temperature
Ambient Temperature : Ta()
Power Dissipation : Pd (mW)
Page 14
2005.7.29
Single Col or φ3 Flush Mount Round Shape Type
3863X Series
Technical Data(FA)
Pulse Width vs. Maximum Tolerable Peak Current
Condition : Ta = 25
Pulse Width : tw (μs)
Dynamic Drive Rating
Duty cycle vs. Maximum Forward Current
Condition : Ta = 25
Duty (%)
Maximum Forward Current : IF MAX. (mA)
IFpeak Max./IFDC MAX.
Page 15
2005.7.29
Single Col or φ3 Flush Mount Round Shape Type
3863X Series
Spatial Distri bution Example
Condition : Ta = 25
Spectral Distribution
Relative Intensity vs. Wavelength
Condition : Ta = 25, IF= 20mA
Wavelength [nm]
Relative Intensity
Forward Voltage vs. Forward Current
Condition : Ta = 25
Forward Voltage VF(V)
Forward Current IF(mA)
Forward Current vs. Relative Intensity
Condition : Ta = 25
Forward Current IF(mA)
Relative Intensity
Technical Data(FR)
Ambient Temperature vs. Relativ e Intensity
Condition : IF=20mA
Ambient Temperature : Ta()
Page 16
2005.7.29
Single Col or φ3 Flush Mount Round Shape Type
3863X Series
Derating
Ambient Temperature vs. Maximum Forward Current
Repetition Frequency : f 50Hz
Ambient Temperature : Ta()
Maximum Forward Current : IFMAX. (mA)
Relative Intensity
Technical Data(FR)
Ambient Temperature vs. Forward Voltage
Ambient Temperature : Ta()
Forward Voltage VF(V)
Power Dissipation vs. Ambient Temperature
Ambient Temperature : Ta()
Power Dissipation : Pd (mW)
Page 17
2005.7.29
Single Col or φ3 Flush Mount Round Shape Type
3863X Series
Technical Data(FR)
Pulse Width vs. Maximum Tolerable Peak Current
Condition : Ta = 25
Pulse Width : tw (μs)
Dynamic Drive Rating
Duty cycle vs. Maximum Forward Current
Condition : Ta = 25
Duty (%)
Maximum Forward Current : IF MAX. (mA)
IFpeak Max./IFDC MAX.
Package Dimensions
Page 18
(Unit: mm)
Single Col or φ3 Flush Mount Round Shape Type
3863X Series
2007.10.12
Single Col or φ3 Flush Mount Round Shape Type
3863X Series
Page 19
The detail is described to LED and Photodetector handling precautions of home page:
"Mounting through-hole Type Devices“ and "Soldering", and use it after the confirmation,
please.
TTW (Through The Wave) soldering Conditions
Solder Bath Temp.
Dipping Time
1) The dip solderi n g proc e ss shall b e 2 times maximu m.
2) The product shall be cooled to room temp. before the second dipping process.
Manual Soldering Conditions
Iron tip temp.
Soldering time and frequency
265
5 s
Pre-heating 100 (MAX.
)
(MAX.)
(MAX.)
3 s
2 times
400
(MAX.)
(MAX.)
(MAX.)
The detail is described to LED and Photodetector handling precautions of home page:
"Mounting through-hole Type Devices“ and "Soldering", and use it after the confirmation, please.
2006.3.31
Single Col or φ3 Flush Mount Round Shape Type
3863X Series
Page 20
Reliability Testing Result
Failure Criteria
Reliability Test ing
Result Applic able S tandard T est ing Conditions Dur ation F ailur e
Room T emp.
O per a ting Lif e EIAJ ED-
4701/100(101) Ta = 25, I
F
= Maxium Rated Curr ent 1, 000 h 0/25
Resist anc e to
Solde r ing Heat EIAJ ED-
4701/300(302) 260±5, 1.6mm from package bas e 10s 0/25
T empera ture Cycling EIAJ ED-
4701/100(105)
Minimum Rated Storage Temperature(30min)
Normal T emperature(15min)
Maximum Rated Storage Temperature(30min)
Normal T emperature(15min)
5 cycle s 0/25
W et High T emp.
Storage Life EIAJ ED-
4701/100(103) Ta = 60±2, RH = 90±5% 1, 000 h 0/25
High Temp.
Storage Life EIAJ ED-
4701/200(201) T a = Maximum Rated Storage Temperature 1,000 h 0/25
Low Temp.
Storage Life EIAJ ED-
4701/200(202) T a = Minimum Rated Storage Temperature 1,000 h 0/25
Lead Tension EIAJ ED-
4701/400(401) 10N,1time (
0.4 and F lat Package : 5N) 10s 0/10
Vibration,
Var iable Frequenc y EIAJ ED-
4701/400(403) 98.1m/s
2
(10G), 100 2K Hz s weep for 20min .,
XY Z each direction 2 h 0/10
Items Symbols Conditions Failure criteria
Luminous Intensity Iv I
F
Value of eac h pr oduc t
Luminous Intensity Testing Min. Value Spec. Min. Value x 0.5
F orward Voltage V
F
I
F
Value of eac h pr oduc t
Forward Voltage T es ting Max. Value Spec. Max. Value x 1.2
Reverse Current I
R
V
R
= Ma ximum Rated
Revers e Voltage V T es ting Max. Value Spec. Max. Value x 2.5
Cosmetic Appearance - - Occurrence of notable decoloration,
deformation and cracking
2007.8.31
Special Notice to Customers Using the Products and
Technical Information Shown in This Data Sheet
Single Col or φ3 Flush Mount Round Shape Type
3863X Series
Page 21
1) The technical information shown in the data sheets are limited to the typical characteristics and circuit
examples of the referenced products. It does not constitute the warranting of industrial property nor the
granting of any license.
2) For the purpose of product improvement, the specifications, characteristics and technical data described
in
the data sheets are subject to change without prior notice. Therefore it is recommended that the most
updated specifications be used in your design.
3) When using the products described in the data sheets, please adhere to the maximum ratings for
operating
voltage, heat dissipation characteristics, and other precautions for use. We are not responsible for any
damage which may occur if these specifications are exceeded.
4) The products that have been described to this catalog are manufactured so that they will be used for the
electrical instrument of the benchmark (OA equipment, telecommunications equipment, AV machine,
home
appliance and measuring instrument).
The application of aircrafts, space borne application, transportation equipment, medical equipment and
nuclear power control equipment, etc. needs a high reliability and safety, and the breakdown and the
wrong
operation might influence the life or the human body. Please consult us beforehand if you plan to use our
product for the usages of aircrafts, space borne application, transportation equipment, medical equipment
and nuclear power control equipment, etc. except OA equipment, telecommunications equipment, AV
machine, home appliance and measuring instrument.
5) In order to export the products or technologies described in this data sheet which are under the
“Foreign Exchange and Foreign Trade Control Law,” it is necessary to first obtain an export permit from
the
Japanese government.
6) No part of this data sheet may be reprinted or reproduced without prior written permission from Stanley
Electric Co., Ltd.
7) The most updated edition of this data sheet can be obtained from the address below:
http://www.stanley-components.com
2007.8.31