& ORTEX INTEGRATED PASSIVE INFRARED & MICROWAVE DETECTOR a Veco @ Separate Relay Output for Automatic Trouble Monitoring @ Alarm Memory, Selectable Positive or Negative Input lM LED Remote On/Off Control Input from Control Panel a DETECTION AREA SPECIFICATIONS DX-40/60 TOP VIEW (ft) Detection method Passive Infrared and Microwave 12m x 12m (40ft x 40ft 18m x 18m (60ft x 6Oft Coverage BoB wide soB wide DX-40 AREA Detection zones 82 zones (PIR) Mounting height 1.5 ~ 2.4m (5 ~ Bit) 1.8 ~ 2.4m (6 ~ Bit) DX-60 AREA Sensitivity 2BC (3.6BF ) 2BC (3.6BF ) at 0.6m/s(2ft/s), 12m(40ft) | at 0.6m/s(2ft/s), 18m (60ft) Detectable speed 0.3 ~1.5m/s(1 ~ 5ft/s) Alarm period Approx. 2 sec Alarm output N.C. 28VDC 0.2A max. Tamper switch N.C., Open when cover is removed. ae Warm-up period Approx. 30 sec i . Flicker during warm-up . RED : ALARM, ALARM MEMORY and TROUBLE indicator LED indicator YELLOW : MW and TROUBLE indicator | GREEN : P.I.R. and TROUBLE indicator | Power input 9 ~ 18VDC \) Current draw 12mA (normal), 35mA (max.) at 12VDC RF interference NO Alarm 30V /m y Operating temperature -10BC ~ +50BC (14BF ~ 122BF) , Environment humidity 95% max. y : 9.900GHz/10.525GHz - Microwave frequency 10.687GHz:(U.K. Version) : y Weight 150g (5.30z) DX-40/60PLUS Current draw 17mA (normal), 40mA (max.) at 12VDC TT D.L. terminal LED remote control terminal is Alarm memory Selectable positive and negative control 0 10 15 18(m) Trouble output N.C., 28VDC 0.2A max. . 9.900GHz/10.525GHz Rae 10.687GHz:(U.K.Version) @ue : DX-40, DX-60, DX-40PLUS, DX-60PLUS OPTIONAL BRACKETS FA-1W 70 (2.76) 48.6 (1.91) Wall Mount Bracket, | | Adjustable +45 Horizontally, 0-20 Vertically Downwards 125 (4.92) FA-3 Compact Wall & Ceiling Mount Bracket _ 41 Adjustable +45 Horizontally, TS 0-10 Vertically Downwards aS A 6 U lan vimtnen Combining Quad Zone PIR Technology *Specifications and design are subjected to change without prior notice and Unique Microwave Detection NOTE:This unit is designed to detect movement of an intruder and activate an alarm control panel. Being only a part of a complete system, we cannot accept responsibility for any damages or other consequences resulting from an intrusion. This product conforms to security product category of EMC Directive 89/336 EEC. DX-40/60 models are the result of Optex's advanced research with PIR and Microwave technology. Unique advancements include "Microwave Area Shaping Technology" ob & ORTEX and Spherical Lens PIR technology with Quad Zone Logic. The design of this product V OPTEX CO., LTD. (180 9001 Gertied by LRGA) offers easy, trouble-free installation in a compact and attractive housing. These models 4-7-5 Nionohama Otsu, 520-0801 Japan . . . Kas || TEL(77S20047, Fax 077) 822-9022 have features necessary to accommodate virtually any installation. MARC EMER T OPTEX INCORPORATED (USA) Del OPTEX (EUROPE) LTD. (UK) OPTEX SECURITY SAS (FRANCE) OPTEX KOREA CO., LTD. (KOREA) OPTEX SECURITY Sp. z 0.0. (POLAND) No. 75020-06-909-0610 Take Care of the Environment This catalogue uses recycled paperVgc att Microwave sar Area Shaping Technology [- Conventional Model 10 20 Area Shaping Technology Optex Research and Development Department have created a breakthrough in Microwave Detection. The DX-40/60 reduce one of the biggest weak points of microwave detection, that is the penetration of walls and unwanted detection of movement outside the coverage area. In addition, the detection area has uniform sensitivity which minimises false activation's caused by spot movement in the detection area, i.e. small animals. The DX-40/60 are new dimensions in microwave technology. ne . | , Optex Integrated Technology offers - | Oe Pein a New: Dimensions 1 in sae Performance __ Per aeaee a ray Microwave Range Selector Trouble Output Selector ! ADK- -40/60 Only) * The shape of Microwave . ; = Unit is different by its frequency. a 9s ey a . Microwave Sensitivity. . Adjustment C + ahte7 Y it "ih S oo 1 as o3: : 'uitorowalve Unit : : . bo e ; A r ) / se 7 ' { ~ : az Detection Mode ai HDs ge la PAE Sensor era aoe +: Alar Memory Selector fa (DX*40/60 PLUS Only) _ ee LED ON/OFF Switch 3LEDIndicators >) 4": Tamper, Switch 7 ws Easy Knockout ia eee and Mechanical sae Quick and Easy Installation with Unique Compact Housing Mi Easy installation and wiring are engineered into this compact housing. Mi Easy Microwave Area Adjustment: Long or Short Distance Selector Switch Low, Medium or High Sensitivity Adjustment pn meee) ea Patented Quad Zone Logic with New Spherical Lens By utilising Optex Advanced Optical Technology, the DX-40/60 create evenly distributed sensitivity throughout the detection area. Accurate focus creates even sensitivity and high resistance to spot temperature changes. Other detectors may have inconsistent detection creating hot spots (false alarm can occur) and dead spots (no detection). In addition, the New Spherical Lens contributes to a superior aesthetic appearance which end users will appreciate. Integrated Microwave & Passive Infrared Technology Improved Tolerance to Spot Movements No Temperature or Light Disturbance Re-Enforced with Electronic Analysis No Penetration The DX-40/60 achieve Protection against False Alarms by utilising an integrated analysis of both PIR and Microwave signals. Fail-Safe Technology Automatic Trouble Monitoring Passive Infrared does not detect through walls and is never affected by movement beyond these boundaries. Anti-PIR Tamper Function (Patent Pending) When PIR Detection fails (something near the detector = blocking the field of view), a i trouble output will generate via the * alarm output (selectable option with DX-40/60) and LED Display. * DX-40/60 PLUS have separate Relay Output PIR Tamper Detection @ Microwave Watchdog Circuit (Self-Checking Function) When microwave operation fails, DX-40/60 automatically switch to single PIR operation in Enhanced Reliability Mode avoiding Missed Alarms. Trouble-Free Installation Microwave Area Shaping allows for simple two step adjustment. By making minor adjustments to the Long or Short Range Selector and the Low, Medium, High Sensitivity Volume, the microwave can be shaped to match room size. This technology will not only reduce installation hassle but will reduce false alarms caused by penetration of walls by the microwave detector. @Wiring Guide & Wide Space at @High Visibility LED Display Terminals (3 LEDs) Increases ease Selectable =. of installation on/off = Easy Knockout \ LOT @ Easy to operate Pin Switches (with instruction directly on the detector) Detection Area Size Configuration Microwave Area Shaping Technology and Quad Zone Logic The Microwave Area can be easily shaped to fit the desired area and have even sensitivity. In addition, Quad Zone Logic in the PIR provides high tolerance to spot temperature changes and ts movements (m) 2.4 caused by small | 6 | animals, heating vents, moving curtains and vibrations a ti caused by big machinery. 0 5 #10 15 20 25 30 35 40 45 50 55 60(ft) 0 0 10 15 18(m) 4. No False Alarms due to Penetration through walls Passive Infrared does not detect through walls and is never affected by movement beyond these boundaries. No False Alarms by Spot Temperature Changes DX-40/60 are not affected by spot temperature changes or by sunlight caused by the movement of sunlight through a detection area. Enhanced Sealed Optics (Patent Pending)