1:
2:
3:
4:
5:
+72 °C
+55 °C
+25 °C
0 °C
−30 °C
1.2
1.0
0.8
0.6
0.4
0.2
0.0
Capacity to 2 Volts / Ah
0.01 0.1 1 10 100 1000
Current / mA
Available Capacity
1
2
3
4
5
1:
2:
3:
4:
5:
6 mA
2 mA
0.6 mA
0.2 mA
0.02 mA
1
2
3
4
5
Operating Voltage
Temperature / °C
Voltage / V
3.8
3.6
3.4
3.2
3.0
2.8
2.6
2.4
−50 −35 −20 −5 10 25 40 55 70 85 100
Typical Discharge Curves at +25 °C
4.0
3.5
3.0
2.5
2.0
1.5
1.0
0.5
0.0
Voltage / V
0.1 1 10 102103104105
Time / h
1:
2:
3:
4:
5:
6:
7:
560 Ω
1.8 kΩ
5.6 kΩ
18 kΩ
56 kΩ
180 kΩ
560 kΩ
~6 mA
~2 mA
~0.6 mA
~0.2 mA
~0.06 mA
~0.02 mA
~0.006 mA
0.90 Ah
1.10 Ah
1.20 Ah
1.15 Ah
1.05 Ah
0.95 Ah
0.85 Ah
1 2 3 4 5 6 7
Ø 4.2
0.15 thick
0.2 thick
1–0.1
4+0.5
3.5
0.2 thick
1–0.1 10.16
4+0.5
3.5
45 45
3.17
Ø 14.7–1.2
Ø 0.8
Ø 0.8
25.2
–1.2
0.7
±0.3
7
±0.5
+0.2
−0.3
Any values given here are for informational purposes only. They also depend on actual
conditions of use and are not warranties of future performance. Subject to change.
Tadiran Batteries GmbH • Industriestr. 22 • 63654 BÜDINGEN
GERMANY • Tel.: +49 (0)6042 954-0 • www.tadiranbatteries.de
PDC13Eng
6
LTC Batteries
Performance Data
(Typical values for batteries stored at +25 °C for one year)
WARNING:
Fire, explosion, and
severe burn hazard. Do not
recharge, disassemble, heat
above 100 °C, incinerate, or
expose contents to water.
SL-350 Size: ½AA
System Lithium Thionyl Chloride
Nominal voltage 3.6 V
Nominal capacity 1.2 Ah
Nominal current 0.6 mA
Max. continuous discharge current 6 mA
Anode surface area 6 cm2
Lithium content 0.35 g
Weight 9.6 g
Volume 4 cm3
Temperature range −55 °C ... +85 °C
› Standard use and stand-by
Available Terminations Catalogue No.
SL-350/S Standard 11 1 03501 00
SL-350/T Tags 11 1 03502 00
SL-350/P Pins 11 1 03503 00
SL-350/PR Pins radial 11 1 03506 00
SL-350/PT Polarized tags 11 1 03508 00
SL-350/S SL-350/T
SL-350/P
SL-350/PTSL-350/PR