Features Unregulated Converters Description ECONOLINE Pot-Core Transformer - separated windings High 5.2kVDC Isolation in compact size Optional Continuous Short Circuit Protected Pin Compatible with RH and RK Series Approved for Medical and IGBT Applications UL and EN Certified Efficiency to 82 % DC/DC-Converter with 3 year Warranty The RP series has very high isolation of 5.2 kVDC in a compact size. The converters are EN-60601-1 certified, making them suitable for medical as well as IGBT driver applications. 1 Watt SIP 7 Single & Dual Output The /X2 version has rearranged pins to permit an input output seperation of more than 9mm. Selection Guide Part Number SIP 7 Input Voltage (VDC) Output Voltage (VDC) Output Current (mA) RP-xx3.3S* 5, 9, 12, 15, 24 3.3 303 70 2200F RP-xx05S* 5, 9, 12, 15, 24 5 200 70-72 1000F RP-xx09S* 5, 9, 12, 15, 24 9 111 75 1000F RP-xx12S* 5, 9, 12, 15, 24 12 84 75-78 470F RP-xx15S* 5, 9, 12, 15, 24 15 66 80 470F RP-xx24S* 5, 9, 12, 15, 24 24 42 80 220F RP-xx3.3D* 5, 9, 12, 15, 24 3.3 152 70 1000F RP-xx05D* 5, 9, 12, 15, 24 5 100 74-76 470F RP-xx09D* 5, 9, 12, 15, 24 9 56 75 470F RP-xx12D* 5, 9, 12, 15, 24 12 42 79-82 220F RP-xx15D* 5, 9, 12, 15, 24 15 33 80-82 220F RP-xx24D* 5, 9, 12, 15, 24 24 21 80 100F 5, 12, 24 +15/-9 42 70-85 220F (%) Max Capacitive Load(1) RoHS 2011/65/EU 6/6 * +15/-9 Version excluded xx = Input Voltage. Other input and output voltage combinations available on request * add Suffix "P" for Continuous Short Circuit Protection, e.g. RP-0505S/P, RP-0505D/P * add Suffix "/X2" for single output with alternative pinning e.g. RP-0505S/X2, RP-0505S/P/X2 Specifications (measured at TA = 25C, nominal input voltage, full load and after warm-up) Input Voltage Range 5% Line Voltage Regulation 3.3V output types 20% max. (10% to 100% full load) 5V output type 15% max. 9V, 12V, 15V, 24V output types, RP-xx1509D 10% max. Output Ripple and Noise (20MHz limited) 100mVp-p max. Operating Frequency 50kHz min. / 100kHz typ. / 120kHz max. RP-xx1509D 50kHz min / 94kHz typ. Efficiency at Full Load 70% min. / 80% typ. Minimum Load = 0% Specifications valid for 10% minimum load only. (tested for 1 second) 5200VDC (rated for 1 minute**) 2600VAC / 60Hz Isolation Capacitance 80 60 30 40 Safe Operating Area 20 0 -40 0 50 100 85 Operating Temperature C 150 **Any data referred to in this datasheet are of indicative nature and based on our practical experience only. For further details, please refer to our Application Notes. 20 GW min. Short Circuit Protection 1 Second P-Suffix Operating Temperature Range (free air convection, without derating) 100 4pF min. / 10pF max. Isolation Resistance Continuous -40C to +85C (see Graph) continued on next page E-66 (Ambient Temperature) 1.2%/1% of Vin typ. Load Voltage Regulation Isolation Voltage RP Derating-Graph 10% Output Voltage Accuracy E-358085 EN-60950-1 Certified IEC/EN-60601-1 Certified* CSA/UL-60950-1 Certified* Output Power (%) RP RP-xx1509D Efficiency REV: 3/2017 www.recom-power.com/eval-ref-boards www.recom-power.com RP Series ECONOLINE DC/DC-Converter Specifications (measured at TA = 25C, nominal input voltage, full load and after warm-up) Storage Temperature Range -55C to +125C Relative Humidity 95% RH Package Weight 2.4g Packing Quantity 25 pcs per Tube MTBF (+25C) (+85C) } Detailed Information see Application Notes chapter "MTBF" using MIL-HDBK 217F 928 x 103 hours using MIL-HDBK 217F 150 x 103 hours Certifications CSA General Safety Report: E358085 CSA C22.2 No. 60950-1-03 UL General Safety Report: E358085 EN General Safety Report: SPCLVD1109103 EN Medical safety Report: SPCMDD1205098-4 UL 60950-1 2nd Ed. EN60950-1:2006 + A12:2011 IEC/EN60601-1:2006, 3rd Edition Notes Note 1 Maximum capacitive load is defined as the capacitive load that will allow start up in under 1 second without damage to the converter. Typical Characteristics RP-xx12S RP-xx05S RP-xx15S Efficiency / Load Efficiency / Load 100 0505 80 100 1205 Efficiency / Load 60 100 80% 60% 40 100% Deviation / Load 25.000 10.000 5.000 0.000 1205 -5.000 -10.000 0 Deviation / Load 40% 0% 20% 0% 20% 40% 60% Total Output current (%) 80% 100% 0.000 1212 -5.000 0% 20% 40% 60% Total Output current (%) 0505 Efficiency % 40 20 40% 60% Total Output current (%) 80% 100% -10.000 80% 100% 1215 Efficiency / Load 0512 1212 60 40 40 20 0% 20% 40% 60% Total Output current (%) 80% 0515 80 60 0 0% 20% 40% 60% Total Output current (%) 0.000 -5.000 RP-xx15D Efficiency % 60 Efficiency % 100% 5.000 100 100 80 20% 80% 0515 10.000 RP-xx12D 1205 100% 15.000 Efficiency / Load 80 80% 20.000 5.000 Efficiency / Load 100 60% 25.000 10.000 -10.000 40% 20% Deviation / Load 100% 0512 15.000 RP-xx05D 0% 80% 60% Total Output current (%) 20.000 0505 Deviation from Nominal (%) Deviation from Nominal (%) 20.000 0% Total Output current (%) 25.000 15.000 0 20 Deviation from Nominal (%) 40% 20% 20 100% 1215 20 0 0% 20% 40% 60% 80% 100% Total Output current (%) continued on next page www.recom-power.com REV: 3/2017 E-67 RP 0% 1215 40 60 Total Output current (%) 0 1212 Efficiency % 20 60 0512 80 Efficiency % Efficiency % 40 0 0515 80 RP Series ECONOLINE DC/DC-Converter Typical Characteristics RP-xx05D RP-xx12D Deviation / Load 25.000 25.000 20.000 Deviation from Nominal (%) 0505 15.000 10.000 5.000 0.000 1205 -5.000 0% 20% 40% 60% Total Output current (%) 100% 80% 20.000 0512 15.000 Deviation from Nominal (%) 20.000 Deviation from Nominal (%) Deviation / Load Deviation / Load 25.000 -10.000 RP-xx15D 10.000 5.000 0.000 1212 -5.000 -10.000 0% 20% 40% 60% Total Output current (%) 15.000 10.000 5.000 0.000 -5.000 -10.000 100% 80% 0515 1215 0% 20% 40% 60% Total Output current (%) 80% 100% Application IGBT Application Circuit Rg IGBT Driver Control Signal IGBT +Vout 7 1 C2 + -Vin Isolated DC/DC Converter C1 + 6 C3 + 5 2 RP -Vout Package Style and Pinning (mm) 7 PIN SIP Package 10.20 4.10 1.27 2.0 7.05 RECOM RP-xxxxD **** 2.0 Dual Output RECOM RP-xxxxS **** RECOM RP-xxxxD **** 0.51 typ. 0.51 typ. 19.65 Bottom View 0.25 Bottom View /X2 Pin Connections Top View Standard Version 1.00 o+0.15/0 2.54 Pin # Single Dual /X2 1 +Vin +Vin +Vin 2 -Vin -Vin -Vin 5 -Vout -Vout No Pin 6 No Pin Com -Vout 7 +Vout +Vout +Vout XX.X 0.5 mm XX.XX 0.25 mm 2.54 1 2 5 6 7 Single Output/X2 9.65 pin clearance 7 5 2.54 2.54 0.25 1 2 Recommended Footprint Details 7.11 pin clearance 19.65 1.27 Single Output RECOM RP-xxxxS/X2 **** 1 2 6 7 Dual Output RECOM RP-xx1509D **** Top View /X2 Version 1 2 5 6 7 The product information and specifications may be subject to changes even without prior written notice. The product has been designed for various applications; its suitability lies in the responsibility of each customer. The products are not authorized for use in safety-critical applications without RECOM's explicit written consent. A safety-critical application is an application where a failure may reasonably be expected to endanger or cause loss of life, inflict bodily harm or damage property. The applicant shall indemnify and hold harmless RECOM, its affiliated companies and its representatives against any damage claims in connection with the unauthorized use of RECOM products in such safety-critical applications. E-68 REV: 3/2017 www.recom-power.com