120 VAC, 5AAC, 60 Hz, input powered
Watt 1P2W, 0-1mA output (1 Element)
Watt 1P2W, 4-20mA output (1 Element)
Watt 3P3W, 0-1mA output (2 Element)
Watt 3P3W, 4-20mA output (2 Element)
Watt 3P4W, 0-1mA output (21⁄2Element)
Watt 3P4W, 4-20mA output (21⁄2Element)
Watt 3P4W, 0-1mA output (3 Element)
Watt 3P4W, 4-20mA output (3 Element)
2469 2489
0-1 Amp AC or 0-5 Amp AC
10 to 200% of rated input 0-200% of rated input
200% of rated input continuous
1000% of rated input for 5 seconds
< 0.2VA per element
120V 240V 120V 240V
100-135VAC 200-264VAC 85-135VAC 170-264VAC
0-120% rated input 0-120% of rated input
< 0.5VA < 1.0VA < 0.3VA < 0.6VA
150% of rated input without damage (Auxiliary powered only)
0 to ±1mADC into 10kΩmax. load; 10VDC output compliance
4-20 mADC into 750Ωmax. load; 15VDC output compliance
0 ± 1mADC = 0.5% of full scale 0±1mADC = ±0.1% rdg. ± 0.05%FS
4-20mADC = 0.5% of span 4-20mADC = ±0.2% of span
120VAC: 1 Amp = 0-100 Watts; 5 Amp = 0-500 Watts
240VAC: 1 Amp = 0-200 Watts; 5 Amp = 0-1000 Watts
Zero: ± 1% minimum Zero: ± 5% minimum
Span: ± 2% minimum Span: ± 10% minimum
< 400 milliseconds (0-99% of output)
0.3% of span peak-to-peak max. 0.5% of span peak-to-peak max.
2500 VAC input to output, power and case
2000 VAC aux. power to output and case
500 VAC output to case
IEEE472/ANSI C37.90.1 - 1989, JIS C1111 (5KV 1.2 x 50 microseconds)
> 10 megohm / 500VDC input/output/power/case
-20°C to +60°C 1mA (-20°to+70°C), 4-20mA(-20°to+60°C)
0 - 90% relative humidity (non-condensing)
±250 PPM / °C of span 1mA ±50FS, 4-20mA ±75span (PPM/°C)
< 0.2% at 400 AT/m
<0.5% <0.2%
<0.25%, 45-65 Hz, fundamental through 9th harmonic
1200g (2.65 lbs.)
<0.2% after 50G, 3 Axis and 6 repetitions
<0.2% after 16.7 Hz, 4 mmp-p 1 hour, 3 Axis
File # E60579
Model #
Current input / range
Current input over range capability
Current input burden
Voltage inputs and range:
Input powered range
Auxiliary powered range
Voltage input burden per element
Sustained Voltage input overange
Rated outputs
Accuracy
Output calibration / element
External calibration adjustment
Response time
Output ripple
Isolation
Surge Withstand Capability
Insulation resistance
Operating temperature
Operating humidity
Temperature effect
External magnetic field
Influence : unbalanced currents /
phase interaction / Power Factor
Influence of frequency
Weight
Shock
Vibration
UL Recognition
NOTE: See order format on next page for additional ratings, frequency calibrations, power-up and output options.
Auxiliary power supply options <5.0 VA burden.
8
2469 (0.5% Accuracy) 2489 (0.2% Accuracy)
246951-540-AFA-0 248951-540-AFA-0
246951-540-AHD-0 248951-540-AHD-0
246953-540-AFA-0 248953-540-AFA-0
246953-540-AHD-0 248953-540-AHD-0
246954-540-AFA-0 248954-540-AFA-0
246954-540-AHD-0 248954-540-AHD-0
246955-540-AFA-0 248955-540-AFA-0
246955-540-AHD-0 248955-540-AHD-0
1) GENERAL
The 2469 and 2489 AC Watt transducers produce an analog output equal to the Watts measured by the
input. The typical calibration is 500 Watts / element for 120V and 5A AC transformer secondary inputs.
2) SPECIFICATIONS
3) STANDARD MODELS
JUXTA AC WATT TRANSDUCERS