15 August 2012 Page 1 5W AC/DC Medical Open Frame FEATURES Universal AC input / Full range Withstand 2G vibration test Cooling by free air convection Green design, No-load power consumption < 0.3W Brown-out ( Low AC Input voltage ) 100% full load burn-in test Medical safety approved Protections: Short circuit / Over load / Over voltage Isolation class 3 Year Warranty All using 105C long life electrolytic capacitors High operation temperature up to 70 C SP-M series SPECIFICATION Rated Power Voltage (4) Over Load Environmental Conditions Input Requirements Ripple & Noise (Max) (2) Voltage Adjustment Range Voltage Tolerance (3) Line Regulation Load Regulation Setup, Rise Time Hold-up Time Protectio n Output Requirements Model Voltage (1) Rated Current Current Range Frequency Efficiency (Typ.) AC Current (max.) Inrush Current (Typ.) Over Voltage Operating Temperature Operating Humidity Storage Temperature, Humidity Temperature Coefficient Vibration www.autec.com SP-M05-05 5V 1A SP-M05-12 12V 0.42A SP-M05-15 15V 0.33A SP-M05-24 24V 0.21A 0~1A 0 ~ 0.42A 0 ~ 0.33A 0 ~ 0.21A 5.04W 4.95W 5.04W 150mV 150mV 240mV 5W 80mV 10% 2% 0.5% 1% 1% 1% 0.5% 0.5% 0.5% 0.5% 100ms, 25ms/230VAC 100ms, 25ms/115VAC at full load 100ms / 230VAC 25ms / 115VAC at full load 1% 0.5% 0.5% 85V ~ 264VAC 125 ~ 373VDC 47Hz ~ 63Hz 71% 75% 75% 77% 0.13 A / 115VAC 0.08A / 230VAC Cold Start 25A / 115VAC 45A / 230VAC 110% rated output power minimum Protection type : Hiccup mode, recovers automatically after fault condition is removed 115% ~ 145% rated output voltage Protection type : latch-off mode, recycle AC to restart -20C ~ +70C (Refer to output load de-rating curve) 20 ~ 90% RH non-condensing - 40 +85 / 10 ~ 95% R.H 0.03%/ (0 ~ 50) 10 ~ 500HZ, 2G 10min./ 1 cycle, period for 60 min. Each along X,Y,Z axes Autec Power Systems Tel: (805)522-0888 667 E Cochran St, Simi Valley, CA93065 Fax: (805)522-8777 26 January 2012 Page 2 Model Safety Standards Safety & EMC (5) Green Energy Withstand Voltage SP-M05-12 SP-M05-15 ENERGY STAR(R) Compliant Single Voltage External AC - DC and AC - AC Power Supplies Eligibility Criteria ( Version 1.1 ) I/P -O/P: 4KVAC I/P -O/P : 100M Ohms / 500VDC EMI Conduction & Radiation EN55011: 2007+A2: 2007 Class B Harmonic Current EN61000-3-2: 2006 Class A, EN61000-3-3: 1995+A1: 2001+A2: 2005 MTBF Dimension (W*H*D) Packing SP-M05-24 UL60601-1/ TUVEN60601-1/ IEC60601-1Approved Isolation Resistance EMS Immunity Others SP-M05-05 EN60601-1-2: 2001+A1: 2006, IEC61000-4-2,3,4,5,6,8,11 light industry level, criteria A 217.4K HRS Compliance: MIL-HDBK-217F 57.9 x 45 x 19.1(mm) or 2.28 x 1.77 x 0.75(inches) 0.033kg ; 192Pcs/6.33kg NOTES: 1. All parameters NOT specially mentioned are measured at 230VAC input, rated load and 25C ambient temperature. 2. Ripple & noise are measured at 20MHz of bandwidth by using a 12" twisted pair-wire terminated with a 0.1uf & 47 uf parallel capacitor. 3. Tolerance: includes set up tolerance, line regulation and load regulation. 4. Line regulation is measured from low line to high line at rated load. 5. Load regulation is measured from 0% to 100% rated load. 6. The power supply is considered a component which will be installed into a final system. The final system must be re-tested to meet EMC directives. 7. Length of set up time is measured at cold first start. Turning ON/OFF the power supply very quickly may lead to increase of the setup time. www.autec.com Autec Power Systems Tel: (805)522-0888 667 E Cochran St, Simi Valley, CA93065 Fax: (805)522-8777 26 January 2012 Page 3 www.autec.com Autec Power Systems Tel: (805)522-0888 667 E Cochran St, Simi Valley, CA93065 Fax: (805)522-8777