Model SP-M05-05 SP-M05-12 SP-M05-15 SP-M05-24
Output Requirements
Voltage (1)
5V
12V
15V
Rated Current
1A
0.42A
0.33A
Current Range
0~1A 0 ~ 0.42A 0 ~ 0.3 3A 0 ~ 0.21A
Rated Power 5W 5.04W 4.95W 5.04W
Ripple & Noise (Max)
(2)
80mV 150mV 150mV 240mV
Voltage Adjustment
Range
±10%
Voltage Tolerance (3)
± 2%
± 1%
± 1%
Line Regulation
±0.5%
±0.5%
±0.5%
Load Regulation
± 1%
±0.5%
±0.5%
Setup, Rise Time
100ms, 25ms/230VAC 100ms, 25ms/115VAC at full load
Hold-up Time 100ms / 230VAC 25ms / 115VA C a t full load
Input
Requirements
Voltage (4) 85V ~ 264VAC 125 ~ 373VDC
Frequency
47Hz ~ 63Hz
Efficiency (Typ.)
71%
75%
75%
AC Current (max.)
0.13 A / 115VAC 0.08A / 230VAC
Inrush Current (Ty p.)
Cold Start 25A / 115VA C 45A / 230VAC
Protectio
n
Over Load 110% rated output power minimum
Protection type : Hiccup mode, recovers automatically after fault condition is removed
Over Volta ge
115% ~ 145% rated output voltage
Protection type : latch-off mode, recycle AC to restart
Environmental
Conditions
Operating Temperature -20°C ~ +70°C (Refer to output load de-rating curve)
Operating Humidity
20 ~ 90% RH no n -condensing
Storage Temperature,
Humidity
- 40 +85
℃ / 10 ~ 95%
R.H
Temperature Coefficient ±0.03%/
℃ (0 ~ 50℃)
Vibration 10 ~ 500HZ, 2G 10min./ 1 cycle, period for 60 min. Each along X,Y,Z axes
5W AC/DC Medical Open Frame SP-M series
Universal AC input / Full range Withstand 2G vibration test
Cooling by free air convection Green design, No-load power consumption < 0.3W
Brown-out ( Low AC Input voltage ) 100% full load burn-in test
Medical safety approved Protections: Short circuit / Over load / Over voltage
Isolation class 3 Year Warranty
All using 105°C long life electrolytic capacitors High operation temperature up to 70 C
SPECIFICATION
FEATURES
Page 2
Autec Power Systems
667 E Cochran St, Simi Valley, CA93065
Tel: (805)522-0888
Fax: (805)522-8777
www.autec.com
26 January 2012
Safety & EMC (5)
Safety Standards UL60601-1/ TUVEN60601-1/ IEC60601-1Approved
Green Energy ENERGY STAR® Compliant Single Voltage External AC DC and AC AC Power Supplies Eligibility Criteria ( Version 1.1 )
Withstand Voltage I/P -O/P: 4KVAC
Isolation
Resistance I/P -O/P : 100M Ohms / 500VDC
EMI Conduction &
Radiation EN55011: 2007+A2: 2007 Class B
Harmonic Current EN61000-3-2: 2006 Class A, EN61000-3-3: 1995+A1: 2001+A2: 2005
EMS Immunity EN60601-1-2: 2001+A1: 2006, IEC61000-4-2,3,4,5,6,8,11 light industry level, criteria A
Others
MTBF
217.4K HRS Compliance: MIL-HDBK-217F
Dimension
(W*H*D) 57.9 x 45 x 19.1(mm) or 2.28 x 1.77 x 0.75(inches)
Packing 0.033kg ; 192Pcs/6.33kg
Model SP-M05-05 SP-M05-12 SP-M05-15 SP-M05-24
NOTES:
1. All parameters NOT specially mentioned are measured at 230 VAC input, rated load and 25C ambient temperatur e.
2. Ripple & noise are measured at 20MHz of bandwidth by using a 12" twisted pair-wire terminated with a 0.1uf & 47 uf parallel
capacitor.
3. Tolerance: includes set up tolerance, line regulation and load regulation.
4. Line regulation is measured from low line to high line at rated load.
5. Load regulation is measured from 0% to 100% rated load.
6. The power supply is considered a component which will be installed into a final system. The final system must be re-tested
to meet EMC directives.
7. Length of set up time is measured at cold first start. Turning ON/OFF the power supply very quickly may lead to increase of the