Revised: January 7, 2009
135
© 2009 Littelfuse, Inc.
Specifications are subject to change without notice.
Radial Lead Fuses
303 Series
Please refer to www.littelfuse.com/series/303.html for current information.
TR3® > Fast-Acting > 303 Series
303 Series
Description
Agency Approvals
Agency Agency File Number Ampere Range
E67006 50mA-5A
051378 50mA-5A
Features
Electrical Characteristics
% of Ampere
Rating Opening Time
200 60 Seconds, Maximum
Applications
Electrical Characteristics
Note: 1.00 means the number one with two decimal places. 1,000 means the number one thousand.
303 Series, TR3®, Fast-Acting Fuse
Amp Code Rated
Current
Voltage
Rating Breaking Capacity
Voltage
Drop
1.0 x IN
max. (mV)
Power
Dissipation
1.0 x IN
max. (mW)
Melting
Integral
10 x IN
max. (A2s)
Approvals
0050 50mA 125V
50A / 125VAC
60-60 Hz/cos ϕ - 1
50A / 63 VDC
800 40 0.00007 XX
0063 63mA 125V 780 50 0.00013 XX
0080 80mA 125V 730 60 0.0002 XX
0100 100mA 125V 700 70 0.0004 XX
0125 125mA 125V 650 85 0.0022 XX
0160 160mA 125V 600 100 0.0029 XX
0200 200mA 125V 550 110 0.0042 XX
0250 250mA 125V 500 125 0.0082 XX
0315 315mA 125V 450 145 0.015 XX
0400 400mA 125V 400 160 0.025 XX
0500 500mA 125V 380 190 0.042 XX
0630 630mA 125V 160 100 0.015 XX
0800 800mA 125V 155 125 0.025 XX
1100 1.00A 125V 150 155 0.039 XX
1125 1.25A 125V 145 185 0.059 XX
1160 1.60A 125V 140 225 0.11 XX
1200 2.00A 125V 130 260 0.17 XX
1250 2.50A 125V 125 315 0.23 XX
1315 3.15A 125V 120 380 0.45 XX
1400 4.00A 125V 110 440 1.0 XX
1500 5.00A 125V 105 525 1.5 XX
t 3FEVDFE1$#TQBDF
requirements
t %JSFDUTPMEFSBCMFPS
plug-in versions
t *OUFSOBUJPOBMMZ
approved
t -PXJOUFSOBMSFTJTUBODF
t 4IPDLTBGFDBTJOH
t 7JCSBUJPOSFTJTUBOU
t )BMPHFOGSFF
t -FBEGSFF
t "WBJMBCMFGSPNN"
to 5A
The 303 Series are TR3®, fast-acting type, 125V rated
fuses designed in accordance to UL 248–14.
t #BUUFSZDIBSHFST
t $POTVNFSFMFDUSPOJDT
t 1PXFSTVQQMJFT
t *OEVTUSJBMDPOUSPMMFST