SYSMAC CS-series Controller Link Units CS1W-CLK CSM_CS1W-CLK_DS_E_5_1 New Controller Link Units, Now with 4,000 Send Words * The Controller Link is an FA network that can send and receive large amounts of data easily and at high speed. The Controller Link supports data links that enable sharing data between PLCs and computers and a message service that enables sending and receiving data whenever required. * With Wired Controller Link Units, systems can be flexibly built by using Repeater Units to enable Tbranches, long-distance wiring, and converting part of the network to optical cable. CS1W-CLK23 CS1W-CLK13 CS1W-CLK53 Features * * * * * * Large-capacity data links are easily achieved without programming simply by setting data link tables. Up to 20,000 *1 send/receive words can be set per node for Units (up to 62,000 words for Boards). Data links can be performed with up to 4,000 *2 words per node while ensuring data concurrency. User-set data link tables can be changed while data links are operating. *3 Errors for the entire system can be monitored by using error diagnosis support software and a variety of status flags. With the token ring mode of Optical Ring Controller Link Units/Boards, duplex communications paths enable communications to continue normally even if the cable becomes disconnected. * Detecting locations of disconnection greatly shortens time required for maintenance. * Installing Controller Link Units in a CS1D system enables Duplex Communications Units to further enhance reliability. *4 *1. Supported for unit version 1.2 or later. *2. CS1W-CLK@3 and 3G8F7-CLK@3 are supported. *3. Supported for CS1W-CLK@3, 3G8F7-CLK@3, and models ending with "-V1" (CS1W-CLK12-V1 *5 and CS1W-CLK52-V1 *5 with lot numbers 0306@@_@@@ or later ). *4. Supported for CS1W-CLK13/CLK12-V1 *5/CLK53/CLK52-V1 *5 and CS1D Duplex and Simplex Systems. *5. Discontinuation models in July 2012. 1 CS1W-CLK System Configuration Wired Controller Link Units Basic Wiring (Daisy Chain Connections) A A A T-Branch Wiring and Partial Conversion to Optical Cable B B A A A (1) B 1 km Max. * (1) C D A Long-distance Wiring A B A (2) A C (1) D (1) 1 km Max. * A: Wired Controller Link Unit B: Wired Controller Link Support Board C: Wire-to-Optical Repeater Unit D: Wire-to-Wire Repeater Unit * At 500 kbits/s A (1) D (1) 1 km Max. * A B 1 km Max. * (1) (1): Twisted-pair cable (2): Optical cable Optical Controller Link Units Token Ring Mode A Token Bus Mode B A A B A B B (1) (1) A A A A A A A: Optical Ring Controller Link Unit B: Optical Ring Controller Link Support Board (1): Optical cable 2 CS1W-CLK Ordering Information Controller Link Units Unit classification Specifications Product name Controller Link Unit CS1 CPU Bus Unit Controller Link Unit Communications cable Communications type Wired shielded twisted-pair cable *1 Optical ring H-PCF cable *2 Controller Link Unit Optical ring GI cable *3 Duplex support Max. Units mountable per CPU Unit No 8 Yes. Unit duplexing and cable loop back are supported. Non-duplex: 8, Duplex: 11 (6 Units comprising 3 sets of Duplex Units + 5 Non-duplex Units) Data links and message service No. of unit numbers allocated Current consumption (A) Model 5V DC 26 V DC 1 0.33 - CS1W-CLK23 1 0.52 - CS1W-CLK13 1 0.65 - CS1W-CLK53 Standards UC1, N, L, CE *1. Use the following special cable for shielded, twisted-pair cable. * ESVC0.5x2C-13262 (Bando Electric Wire : Japanese Company) * ESNC0.5x2C-99-087B (Nihon Electric Wire & Cable Corporation : Japanese Company) * ESPC 1Px0.5mm2 (Nagaoka Electric Wire Co.,Ltd. : Japanese Company) * Li2Y-FCY2x0.56qmm (Kromberg & Schubert, Komtec Department : German Company) * 1x2xAWG-20PE+Tr.CUSN+PVC (Draka Cables Industrial : Spanish Company) * #9207 (Belden : US Company) *2. When using a wire-to-optical (H-PCF) cable, use a H-PCF cable (for both Controller Link and SYSMAC LINK) or a H-PCF optical fiber cable with connector. *3. When using a wire-to-optical (GI) cable, use a GI optical cable that matches the specifications. Accessories The Optical Fiber Cable Bracket is included in CS1W-CLK13 and CS1W-CLK53. 3 CS1W-CLK Controller Link Support Boards Specifications Product name Communications cable Controller Link Support Board for PCI Bus Wired shielded twisted-pair cable H-PCF optical model Accessories Communications type Data links and message service GI optical model Model * CD-ROM x 1 * * INSTALLATION GUIDE (W467) x 1 * Communications connector x 1 * CD-ROM x 1 * * INSTALLATION GUIDE (W467) x 1 * Optical Fiber Cable Bracket x 1 * Power supply connector x 1 Standards 3G8F7-CLK23-E CE 3G8F7-CLK13-E 3G8F7-CLK53-E * The CD-ROM contains the following software. * Controller Link (PCI) Driver * FinsGataway Version 2003 (PCI-CLK Edition) * FinsGataway Version 3 (PCI-CLK Edition) * Setup Diagnostic Utility * C Library Repeater Units Name Specifications Controller Link Repeater Unit CS1W-RPT0 PWR T/R1 1 T/R2 Model Wire-to-Wire Model CS1W-RPT01 Wire-to-Optical (H-PCF) Model (See note 1.) CS1W-RPT02 Wire-to-Optical (GI) Model (See note 2.) CS1W-RPT03 Standards UC1, CE SL1 TER SW SW1 1 BAUD 2 RATE ON TER SW SL2 DC24V INPUT Using Repeater Units enables T-branches and long-distance wiring for Wired Controller Link networks, 62-node configurations, and converting part of the network to optical cable. Note: 1. When using wire-to-optical (H-PCF) cable, use a H-PCF cable (for both Controller Link and SYSMAC LINK) or a H-PCF optical fiber cable with connector. 2. When using wire-to-optical (GI) cable, use a GI optical cable (for Controller Link). Relay Terminal Block Name Specifications Model Standards Relay Terminal Blocks for Wired Controller Link Units Used for Wired Controller Link Units (set of 5) - CJ1W-TB101 Controller Link Units can be replaced without stopping the communications of the entire network if a Relay Terminal Block is installed in advance on the Unit in a Wired Controller Link network. Relay Terminal Blocks cannot be used on Controller Link Support Boards. Duplex Optical Fiber Cable (H-PCF Cable) Name Duplex Optical Fiber Cable Application Specifications CS1W-CLK13 or H-PCF cable for connecting Duplex Controller Link Units CS1W-CLK12-V1 * in a CS1D system Cable length: 50 cm Model CS1D-CN051 Standards - This cable is used to connect Units in active mode (ACT) and standby mode (STB) in a CS1D Duplex System. * Discontinuation models in July 2012. 4 CS1W-CLK H-PCF Cables and Optical Connectors Name Application/construction Specifications 1 2 3 4 Optical Fiber Cables Controller Link, SYSMAC LINK, SYSBUS 5 6 1. Optical fiber single-core cord 2. Tension member (plastic-sheathed wire) 3. Filler (plastic) 4. Filler surrounding signal wires (plastic, yarn, or fiber) 5. Holding tape (plastic) 6. Heat-resistant PV sheath Controller Link: SYSMAC LINK: Optical Connectors (Crimp-cut) Controller Link: SYSMAC LINK: Two-core optical cable with tension member Model Standards Black 10 m S3200-HCCB101 Black 50 m S3200-HCCB501 Black 100 m S3200-HCCB102 Black 500 m S3200-HCCB502 Black 1000 m S3200-HCCB103 Orange 10 m S3200-HCCO101 Orange 50 m S3200-HCCO501 Orange 100 m S3200-HCCO102 Orange 500 m S3200-HCCO502 Orange 1000 m S3200-HCCO103 CS1W-CLK13 CS1W-CLK12-V1 *1 3G8F7-CLK13-E 3G8F7-CLK12-EV1 *1 CS1W-RPT02 CS1W-SLK11 3G8F7-SLK11-E C200HW-SLK13/14 Half lock S3200-COCF2571 CS1W-CLK13 CS1W-CLK12-V1 *1 3G8F7-CLK13-E 3G8F7-CLK12-EV1 *1 CS1W-RPT02 3G8F7-SLK11-E Full lock S3200-COCF2071 *2 - *1. Discontinuation models in July 2012. *2. Full-lock Optical Connectors (Crimp-cut) (S3200-COCF2071) cannot be used with the CS1W-SLK11. Use a Half-lock Cable (S3200COCF2571) or a H-PCF Optical Fiber Cable with Connector (S3200-CN@@@-@@-@@). H-PCF Optical Fiber Cables with Connectors (Black Composite Cables with Two-Optical Lines and Two Power Supply Lines) Application Appearance Model Standards S3200-CN@@@-20-20 Controller Link, SYSMAC LINK S3200-CN@@@-20-25 - S3200-CN@@@-25-25 Optical connectors for H-PCF Optical Cables with Connectors are adhesive polished. Cable Length The following cable lengths are available: 2 m, 5 m, 15 m, and 20 m. For lengths of 21 m or more, contact your OMRON sales representative. Model Numbers (1) 2 m, 5 m, 10 m, 15 m, or 20 m (2) 21 m or longer S3200-CN@@@ @@@-20-25 1. 1. H-PCF Optical Fiber Cable 2. S3200-CN-20-20 1. 3. 2. Cable length @@@ Length 201 2m 501 5m 102 10 m 152 15 m 202 20 m 3. Specify the cable length in meters. 3. Connectors (both ends) Number Connector lock 20 Full-lock 25 Half-lock Cable length 5 CS1W-CLK Optical Connector Assembly Tool Name Applicable Unit Model Manufacturer Standards Optical This tool is used on site for mounting crimp-cut connectors and hard Fiber Sumitomo Electric CAK-0057 - Assembly plastic-clad silica optical fiber for optical transmission systems of Industries, Ltd. SYSMAC C-series SYSBUS, SYSMAC LINK, and Controller Link. Tool (See note.) Note: There is a risk of quality problems when using cables assembled by typical users, so we recommend purchasing cables with preattached connectors or having a qualified technician assemble the cables. GI Optical Cables A qualified technician must select, assemble, and install GI Optical Fiber Cable, so always let an optical cable specialist handle the GI cable. Usable Optical Cables and Optical Connectors * Optical fiber types: Graded, indexed, multi-mode, all quartz glass, fiber (GI-type AGF cable) * Optical fiber construction (core diameter/clad diameter): 62.5/125 m or 50/125 m * Optical fiber optical characteristics of optical fiber: Refer to the tables. * Optical connector: ST connector (IEC-874-10) * 50/125-m AGF Cable Item Minimum Numerical aperture (N.A) - Transmission loss (dB) Transmission bandwidth (MHz-km) Standard Maximum - - - - 500 Conditions Item Minimum - Numerical aperture (N.A) - - 0.21 - Connection loss (dB) * 62.5/125-m AGF Cable 3.0Lf 0.5 km Lf 3.0Lf+0.2 0.2 km Lf 0.5 km 3.0Lf+0.4 Lf 0.2 km 1.0 - = 0.8 m Ta = 25C Transmission loss (dB) = 0.8 m, one location Connection loss (dB) = 0.85 m (LD) Transmission bandwidth (MHz-km) Lf is fiber length in km, Ta is ambient temperature, and is the peak wavelength of the test light source. - - 200 Standard Maximum Conditions - - 0.28 - - 3.5Lf 0.5 km Lf 3.5Lf+0.2 0.2 km Lf 0.5 km 3.5Lf+0.4 Lf 0.2 km 1.0 = 0.8 m, one location - - = 0.8 m Ta = 25C = 0.85 m (LD) Lf is fiber length in km, Ta is ambient temperature, and is the peak wavelength of the test light source. International Standards * The standards indicated in the Standards column are those current for UL, CSA, cULus, cUL, NK, and Lloyd standards and EC Directives as of the end of July 2007. The standards are abbreviated as follows: U: UL, U1: UL (Class I Division 2 Products for Hazardous Locations), C: CSA, UC: cULus, UC1: cULus (Class I Division 2 Products for Hazardous Locations), CU: cUL, N: NK, L: Lloyd, and CE: EC Directives. * Ask your OMRON representative for the conditions under which the standards were met. Mountable Racks CS1 System Model CPU Rack CS1W-BC @@3 CS1W-CLK23 CS1W-CLK13 CS1W-CLK53 Unit version 2.0 CS1W-CLK21-V1 CS1W-CLK12-V1 *1 CS1W-CLK52-V1 Unit version 1.2 CS1W-CLK21-V1 CS1W-CLK12-V1 *1 CS1W-CLK52-V1 Pre-Ver. 1.2 @@2 Expansion Backplane (including Long-distance Expansion Rack) CS1W-BI @@3 @@2 CS1D System SYSBUS Remote I/O Slave Rack C200HX/HG/ HE Expansion I/O Rack CPU Rack CS1D-BC 052 042D Expansion Backplane CS1D-BI 082S 092 082D 8 Units (per CPU Unit) 8 Units (per CPU Unit) Not supported 4 Units (per CPU Unit) Not supported 8 Units *2 (per CPU Unit) 4 Units *3 (per CPU Unit) *1. Discontinuation models in July 2012. *2. Optical Ring Controller Link Units support 11 Units maximum for duplex (6 Units comprising 3 sets of Duplex Units + 5 Non-duplex Units). *3. Optical Ring Controller Link Units support 7 Units maximum for duplex (6 Units comprising 3 sets of Duplex Units + 1 Non-duplex Unit). 6 CS1W-CLK Communications Specifications Items Specifications Model CS1W-CLK23 3G8F7-CLK23-E CS1W-CLK21-V1 *1 3G8F7-CLK21-EV1 *1 CS1W-CLK13 3G8F7-CLK13-E CS1W-CLK12-V1 *1 3G8F7-CLK12-EV1 *1 CS1W-CLK53 3G8F7-CLK53-E CS1W-CLK52-V1 *1 3G8F7-CLK52-EV1 *1 Type Optical Ring (GI cable) Wired (shielded twisted-pair cable) Optical Ring (H-PCF cable) Communications method N:N token-bus method N:N token-ring method (token-ring mode) N:N token-bus method (token-bus mode) Code Manchester code Modulation Baseband code Synchronization Flag synchronization (conforms to HDLC frames) Transmission path format Multidrop method (bus type) The following are the maximum transmission distances depending on the transmission speed. 2 Mbits/s: 500 m Maximum 1 Mbits/s: 800 m transmission distance 500 kbits/s: 1 km Transmission speed * Ring method (token-ring mode) * Daisy-chain method (token-ring mode) 2 Mbits/s 20 km 30 km Maximum distance between nodes Not specified. (Maximum transmission Crimp-cut: 800 m distance must be satisfied for the Adhesive polishing: 1 km *2 entire system.) 62.5/125 m: 2 km 50/125 m: 1 km Medium Specified shielded twist-pair cable Two signal wires, one shield H-PCF cable (two-core optical cable) GI cable (two-core optical cable: 62.5/125 m, 50/125 m) Node connection method PLC: Connection to terminal block Computer: Connection using special (supplied) connector Connection using special connector (full-lock connector or half-lock connector) Connection using ST connector Maximum number of nodes 32 or 62 nodes *3 *4 62 *5 Applicable CX-Integrator in CX-One, CX-Net in CX-Programmer *4, and Programming Console Programming Devices Communications functions Data links and message service Number of data link words Send words per node: 4,000 words max. (CS1W-CLK@3), 1,000 words max. (All other Units) Number of send/receive words per node: 12,000 words max. (Pre-Ver. 1.2) 20,000 words max. (unit Ver. 1.2 or later) Total number of send words per network: 62,000 words max. Data link areas PLC: Bit areas (CIO Area, Work Area, Link Area *6), Data Memory (DM), Extended DM Area (EM) Computer: FinsGateway event memory Message length 2,012 bytes max. (including the header) RAS functions * Polling node backup function * Self-diagnosis function (hardware checking at startup) * Echoback test and broadcast test (using the FINS command) * Watchdog timer * Error log function Error control Manchester code check CRC check (CCITT X16+X12+X5+1) * Polling node backup function * Self-diagnosis function (hardware checking at startup) * Echoback test and broadcast test (using the FINS command) * Watchdog timer * Error log function * Node bypass function * Transmission path duplication (for ring method in token-ring mode only) * Disconnect detection and notification (token-ring mode only) * Node connection configuration data reading (for ring method in token-ring mode only) * Duplex operation of Communications Units *7 *1. Discontinuation models in July 2012. *2. The maximum distance between nodes depends on the processing method for connectors and cables. *3. With wired models, the maximum number of nodes is 32 if Repeater Units are not used. A Repeater Unit is required when building a network with more than 32 nodes. If a Repeater Unit is used, be sure to use only the following Controller Link Units or Boards and set the Wired Network 62 Node Enable Bit in the DM Parameter Area software switches at all nodes. CS1W-CLK23/CLK21-V1 *1 CJ1W-CLK23/CLK21-V1 *1 3G8F7-CLK23-E/CLK21-EV1 *1 *4. CX-Net in CX-Programmer version 3.1 or earlier can be used only in a system with a maximum of 32 nodes (node address 1 to 32). If a system is to be used with a maximum of 62 nodes (node addresses 1 to 62), use CX-Net in CX-Programmer version 3.2 or higher or the CX-Integrator. *5. If duplex Controller Link Units are used, the effective maximum number of nodes will be 62 (i.e., the maximum number of nodes in standby mode (STB)). *6. CS-series PLCs do not have a Link Area, but LR000 to LR199 are automatically converted CIO 1000 to CIO 1199. *7. Only when a CS1W-CLK13/12-V1 *1/53/52-V1 *1 installed in a CS1D system is used in token ring mode. 7 CS1W-CLK Individual Specifications Controller Link Units Item Model Supported PLC Number of mountable Units Installation site Storage location for network parameters and manually set data tables Storage location for routing tables Weight Specifications CS1W-CLK23 CS1W-CLK13 CS1W-CLK53 CS1W-CLK21-V1 * CS1W-CLK12-V1 * CS1W-CLK52-V * All CS-series CPU Units Unit version 1.2 or later: 8 Units max., Pre-Ver. 1.2: 4 Units max. Install onto a CPU Backplane or CS-series Expansion Backplane (classified as a CPU Bus Unit). CPU Bus Unit Area (in the CPU Unit parameter area) CPU Unit parameter area 220 g 5 V in PLC 26 V in PLC External 24 V * Discontinuation models in July 2012. Current consumption 0.33 A - - 300 g (excluding mounting bracket) 0.52 A - 0.20 A 300 g (excluding mounting bracket) 0.65 A - 0.26 A Controller Link Support Boards (for PCI Bus), New Models Item Specifications 3G8F7-CLK23-E 3G8F7-CLK13-E 3G8F7-CLK53-E IBM PC/AT or compatible * CPU: Intel Celeron 400 MHz or better * Main memory: 128 MB minimum * One or more PCI bus slots (PCI bus revision 2.0 or higher, power supply: 5 V) Applicable computers * Available hard disk space: 70 MB min. * CD-ROM drive: One required for installation * Display: VGA (640 x 480 (pixels) min.) (Other conditions conform to the OS.) * FinsGateway Version 2003 (See note 1.) Windows 7 (32bit) Professional Windows 7 (32bit) Home Premium Windows Vista Business Windows Vista Home Premium Windows XP Professional Windows XP Home Edition Compatible OS Windows 2000 Professional * FinsGateway Version 3 (See note 2.) Windows XP Professional Windows XP Home Edition Windows 2000 Professional Windows NT 4.0 (Service Pack 3 or higher) Windows ME Windows 98SE Weight 104 g 120 g (excluding mounting bracket) 124 g (excluding mounting bracket) 5 V in PLC 0.35 A 0.54 A 0.60 A Current consumption External 24 V - 0.35 A 0.35 A Note: 1. Install the software from CD Ver. 3.10 or higher if the operating system is Windows 7 (32bit) or Windows Vista. 2. Install FinsGateway version 3 if the operating system is Windows NT 4.0 (Service pack 3 or higher), Windows ME, or Windows 98SE. In that case, however, the new functions of Controller Link Support Boards for the PCI Bus cannot be used (i.e., automatic data link creation with 1:N allocation, changing data link tables with active data links, 62-node setting for wired models, and maximum of 4000 send words). Models Controller Link Support Boards (for PCI Bus), Old Models Models *1 Item Applicable computers Compatible OS *2 Specifications 3G8F7-CLK21-EV1 3G8F7-CLK12-EV1 3G8F7-CLK52-EV1 IBM PC/AT or compatible * CPU: Intel Celeron 400 MHz or better * Main memory: 128 MB minimum * One or more PCI bus slots (PCI bus revision 2.0 or higher, power supply: 5 V) * Available hard disk space: 70 MB min. * CD-ROM drive: One required for installation * Display: VGA (640 x 480 (pixels) min.) (Other conditions conform to the OS.) * FinsGateway Version 2003 Windows XP Professional Windows XP Home Edition Windows 2000 Professional * FinsGateway Version 3 Windows XP Professional Windows XP Home Edition Windows 2000 Professional Windows NT 4.0 (Service Pack 3 or higher) Windows ME Windows 98SE 104 g 120 g (excluding mounting bracket) 124 g (excluding mounting bracket) 0.35 A 0.54 A 0.60 A - 0.35 A 0.35 A Weight 5 V in PLC Current consumption External 24 V *1. Discontinuation models in July 2012. *2. Install FinsGateway version 3 if the operating system is Windows NT 4.0 (Service pack 3 or higher), Windows ME, or Windows 98SE. In that case, however, the new functions of Controller Link Support Boards for the PCI Bus cannot be used (i.e., automatic data link creation with 1:N allocation, changing data link tables with active data links, 62-node setting for wired models, and maximum of 4000 send words). 8 CS1W-CLK Repeater Units Item Specifications CS1W-RPT01 CS1W-RPT02 CS1W-RPT03 All wired Controller Link Units and Boards Supported Units and Boards Note: If a maximum of 62 nodes is used, models that support 62 nodes must be used. Transmission path Wire-to-wire Wire-to-optical (H-PCF) Wire-to-optical (GI) Multi-drop Transmission path format 1:1 1:1 Tree Repeater Units are not mounted to the PLC. They are mounted separately with screws or on a DIN Installation Track. 113 g 116 g Weight 126 g (excluding mounting bracket) (excluding mounting bracket) Allowable power supply voltage range 20.4 to 26.4 VDC (24 VDC -15 V to +10%) Current consumption 0.06 A at 24 VDC 0.06 A at 24 VDC 0.07 A at 24 VDC Inrush current 2.5 A max. (24 VDC with rise time of 5 ms) Model Repeater Units are used to expand the Controller Link network for wired models. For Wired-to-optical Repeater Units, always use a set of two (1:1). Optical Ring Controller Link Units and Boards cannot be connected to the optical cable section between Repeater Units. External Interfac CS1W-CLK23/CS1W-CLK21-V1 * LED Indicators Display the Unit and network status. Unit Number Switch One rotary switch. The unit number of the Unit on the PLC is set in single-digit hexadecimal. Node Address Switches Two rotary switches. The node address of the Unit on the Controller Link Network is set in 2-digit decimal. Baud Rate Switches A four-pin DIP switch. The following setting is made. Pins 1 and 2: Baud rate Pins 3 and 4: Not used (always OFF). Terminating Resistance Switch A slide switch. Use this switch to set the terminating resistance to ON for nodes at both ends of the Controller Link Network. * Discontinuation models in July 2012. Terminal Block for the Communications Cable Terminals to connect to the Controller Link Network communications cable (twisted-pair cable). Definition of Terminal Block Pin Names for Communications Cables Marking Notation Signal name Line color BD H Communications data, high Black @ BD L Communication data, low White None SHLD Shield None Crimp Terminals Use crimp terminals (M3) having the dimensions shown below. 6.2 mm max. 6.2 mm max. 9 CS1W-CLK CS1W-CLK13/CS1W-CLK12-V1 * LED Indicators Display the Unit and network status. Unit Number Switch One rotary switch. The unit number of the Unit on the PLC is set in single-digit hexadecimal. Node Address Switches Two rotary switches. The node address of the unit on the Controller Link Network is set in 2-digit decimal. Optical Connectors Connect to communications cables (H-PCF fiber optical cables) for the Controller Link network. * Discontinuation models in July 2012. Power Supply Terminal Block Connect to a backup power supply for the node bypass function. Crimp Terminals Use crimp terminals (M3) having the dimensions shown below. 6.2 mm max. 6.2 mm max. CS1W-CLK53/CS1W-CLK52-V1 * LED Indicators Display the Unit and network status. Unit Number Switch One rotary switch. The unit number of the Unit on the PLC is set in single-digit hexadecimal. Node Address Switches Two rotary switches. The node address of the unit on the Controller Link Network is set in 2-digit decimal. Optical Connectors Connect to communications cables (GI optical cables) for the Controller Link network. Power Supply Terminal Block Connect to a backup power supply for the node bypass function. * Discontinuation models in July 2012. Crimp Terminals Use crimp terminals (M3) having the dimensions shown below. 6.0 mm max. 6.0 mm max. 10 CS1W-CLK Differences in Specifications of New and Old Models Controller Link Units CS1W-CLK23 CS1W-CLK13 CS1W-CLK53 Model Note: The following models are discontinued. Note: The following models are discontinued. Note: The following models are discontinued. CS1W-CLK21-V1 CS1W-CLK12-V1 CS1W-CLK52-V1 CS1W-CLK21-V1 CS1W-CLK12-V1 CS1W-CLK52-V1 CS1W-CLK21 CS1W-CLK12 CS1W-CLK52 Unit version 1.2 Pre-Ver. 1.2 Pre-Ver. 1.2 Unit version 2.0 Number of data link send words (data link areas that are created for a single node in a single PLC) 20,000 words max. Number of send words 4,000 words max. per node (total of area 1 (user-set links only) and area 2) 12,000 words max. 1,000 words max. Data link areas Allocation setting can be performed for same areas in areas 1 and 2. Allocation setting can be performed for same areas in areas 1 and 2. Max. Units mountable per PLC 8 4 Automatic data link setting Choose from equality layout or 1:N allocations (common type, 1:1, chain type) Supported for equality layout only. Changing data link allocations during active data links Supported (Data link tables can be changed during active data links.) Not supported. Maximum connectable nodes 62 nodes (See note 1.) Wired model: 32 nodes Optical ring model: 62 nodes Duplex support Supported (optical ring model only) (See note 2.) Not supported Mixed use Yes (See note 3.) Compatible support software CX-Integrator for CX-One V2.1or higher, or CX-Net for CX-Net for CX-Programmer CX-Net for CX-Programmer CX-Net for CX-Programmer CX-Programmer Ver. 7.2 or Ver. 5.0 or higher Ver. 3.2 or higher Ver. 1.0 or higher higher Note: 1. For wired models, the maximum number of nodes is 32 if Repeater Units are not used. 2. Use models with lot numbers 0306@@ (June 2003 production) or later to enable duplexing in a CS1D System using the Pre-Ver. 1.2 CS1W-CLK12-V1 or CS1W-CLK52-V1. 3. Old models and new models can be used mixed on the same network. In that case, however, build the system using the specifications for the old models. The data link send/receive words can be separately set to their maximums when new and old models are mixed. Controller Link Support Boards (for PCI Bus) Model 3G8F7-CLK23-E 3G8F7-CLK13-E 3G8F7-CLK53-E Note: The following models are discontinued. Note: The following models are discontinued. 3G8F7-CLK21-EV1 3G8F7-CLK12-EV1 3G8F7-CLK52-EV1 3G8F7-CLK21-E 3G8F7-CLK12-E 3G8F7-CLK52-E Number of data link send/ receive words (data link areas for sending/receiving that are created for a single node in a single computer) 62,000 words max. Send words per node 4,000 words max. (user-set links only) Changing data link allocations during active data links Supported. (Data link tables can be changed during active data links.) 32,000 words max. 1,000 words max. Wired model: 32 nodes Optical ring model: 62 nodes Maximum connectable nodes 62 nodes (See note 1.) Mixed use Yes (See note 2.) Compatible FinsGateway (See note 3.) FinsGateway Version 2003.21 or higher (In CD Ver. 3.00 or higher) CX-Integrator for CX-One Ver. 2.1 Compatible support software or higher, or CX-Net for CX-Programmer Ver. 7.2 or higher Not supported. FinsGateway Version 2003.00 or higher (In CD Ver. 2.00 or higher) FinsGateway Version 3.00 or higher (In CD Ver. 1.00 or higher) CX-Net for CX-Programmer Ver. 3.2 or higher CX-Net for Ver. 1.0 or higher Note: 1. For wired models, the maximum number of nodes is 32 if repeater units are not used. 2. Old models and new models can be used mixed on the same network. In that case, however, build the system using the specifications for the old models. The data link send/receive words can be separately set to their maximums when new and old models are mixed. 3. FinsGateway Version 2003 is compatible with Windows 7 (32bit) (CD Ver.3.10 or higher), Windows Vista (CD Ver.3.10 or higher), Windows XP and Windows 2000. For Windows NT4.0 (Service Pack 3 or higher), Windows ME, or Windows 98SE, use FinsGateway Version3. (With FinsGateway Version 3, only functions supported by the 3G8F7-CLK21/CLK12/CLK52 can be used.) 11 CS1W-CLK Usage Precautions * Old models and new models can be used mixed on the same network. In that case, however, build the system using the specifications for the old models. The data link send/receive words can be separately set to their maximums when new and old models are mixed. * Repeater Units can be used to expand a Wired Controller Link Network. For Wired-to-optical Repeater Units, always use a set of two (1:1). Optical Ring Controller Link Units and Boards cannot be connected to the optical cable section between Repeater Units. * Connect Repeater Units so that there are no more than two stages between any two nodes. One set of two Wire-to-Optical Repeater Units is counted as one stage. 12 CS1W-CLK Dimensions (Unit: mm) 130 CS1W-CLK23/CS1W-CLK21-V1 * 35 101 35 101 130 CS1W-CLK13/CS1W-CLK12-V1 * 130 CS1W-CLK53/CS1W-CLK52-V1 * 35 10 (13.5) 101 Note: The dimensions in parentheses are for the CS1W-CLK53 (including the terminal cover). * Discontinuation models in July 2012. 13 CS1W-CLK Related Manuals Cat. No. Models Name Application Description W309 CS1W-CLK23 CS1W-CLK21-V1 CJ1W-CLK23 CJ1W-CLK21-V1 C200HW-CLK21 CVM1-CLK21 CQM1H-CLK21 CS1W-RPT01/02/03 Controller Link Units Operation Manual W422 3G8F7-CLK12-V1 3G8F7-CLK52-V1 3G8F7-CLK21-V1 Used when information Controller Link Support Boards for PCI Bus regarding setup procedures for Controller Link Support Installation Guide Boards for PCI bus (3G8F7-CLK12/21/52-V1) connections is needed. Describes the setup method for the Controller Link Support Boards for PCI bus connections. W467 3G8F7-CLK13 3G8F7-CLK12-V1 3G8F7-CLK53 3G8F7-CLK52-V1 3G8F7-CLK23 3G8F7-CLK21-V1 Used when information Controller Link Support Board for PCI Bus regarding setup procedures for Controller Link Support Installation Guide (3G8F7-CLK13/12-V1/53/52-V1/23/21-V1) Boards for PCI bus connections is needed. Describes the setup method for the Controller Link Support Boards for PCI bus connections. W383 3G8F7-CLK13 3G8F7-CLK12-V1 3G8F7-CLK53 3G8F7-CLK52-V1 3G8F7-CLK23 3G8F7-CLK21-V1 Used when information regarding setup procedures Controller Link Support Boards for PCI Bus for Controller Link Support Operation Manual Boards for PCI bus connections is needed. Describes the setup method for the Controller Link Support Boards for PCI bus connections. Used when information regarding operating procedures for Wired Controller Link Units is needed. Describes operating procedures for Controller Link Units. Controller Link Units can connect to Wired Controller Link Units. W370 CS1W-CLK13 CS1W-CLK12-V1 CVM1-CLK12 CS1W-CLK53 CS1W-CLK52-V1 CVM1-CLK52 Optical Ring Controller Link Units Operation Manual Describes the operating procedures for Controller Link Units. Controller Link Units can Used when information connect to Controller Link regarding operating Networks (Optical Ring System procedures for Optical Ring for H-PCF Cable, or GI Cable) . Model Controller Link Units is Refer to this manual for needed. information regarding the discontinued CS1W-CLK11 Optical Bus Controller Link Unit. W464 CXONE-AL@@C-V@/ AL@@D-V@ CX-Integrator Operation Manual Used when network setup or network monitoring needs to be performed. Describes the operating procedures for the CX-Integrator. W463 CXONE-AL@@C-V@/ AL@@D-V@ CX-One FA Integrated Tool Package Setup Manual Used when installing software from the CX-One. Provides an overview of the FA Integration Tool Package CX-One, and describes the CX-One installation procedures. 14 Read and Understand This Catalog Please read and understand this catalog before purchasing the products. Please consult your OMRON representative if you have any questions or comments. Warranty and Limitations of Liability WARRANTY OMRON's exclusive warranty is that the products are free from defects in materials and workmanship for a period of one year (or other period if specified) from date of sale by OMRON. OMRON MAKES NO WARRANTY OR REPRESENTATION, EXPRESS OR IMPLIED, REGARDING NON-INFRINGEMENT, MERCHANTABILITY, OR FITNESS FOR PARTICULAR PURPOSE OF THE PRODUCTS. ANY BUYER OR USER ACKNOWLEDGES THAT THE BUYER OR USER ALONE HAS DETERMINED THAT THE PRODUCTS WILL SUITABLY MEET THE REQUIREMENTS OF THEIR INTENDED USE. OMRON DISCLAIMS ALL OTHER WARRANTIES, EXPRESS OR IMPLIED. LIMITATIONS OF LIABILITY OMRON SHALL NOT BE RESPONSIBLE FOR SPECIAL, INDIRECT, OR CONSEQUENTIAL DAMAGES, LOSS OF PROFITS OR COMMERCIAL LOSS IN ANY WAY CONNECTED WITH THE PRODUCTS, WHETHER SUCH CLAIM IS BASED ON CONTRACT, WARRANTY, NEGLIGENCE, OR STRICT LIABILITY. In no event shall the responsibility of OMRON for any act exceed the individual price of the product on which liability is asserted. IN NO EVENT SHALL OMRON BE RESPONSIBLE FOR WARRANTY, REPAIR, OR OTHER CLAIMS REGARDING THE PRODUCTS UNLESS OMRON'S ANALYSIS CONFIRMS THAT THE PRODUCTS WERE PROPERLY HANDLED, STORED, INSTALLED, AND MAINTAINED AND NOT SUBJECT TO CONTAMINATION, ABUSE, MISUSE, OR INAPPROPRIATE MODIFICATION OR REPAIR. Application Considerations SUITABILITY FOR USE OMRON shall not be responsible for conformity with any standards, codes, or regulations that apply to the combination of products in the customer's application or use of the products. At the customer's request, OMRON will provide applicable third party certification documents identifying ratings and limitations of use that apply to the products. This information by itself is not sufficient for a complete determination of the suitability of the products in combination with the end product, machine, system, or other application or use. The following are some examples of applications for which particular attention must be given. This is not intended to be an exhaustive list of all possible uses of the products, nor is it intended to imply that the uses listed may be suitable for the products: Outdoor use, uses involving potential chemical contamination or electrical interference, or conditions or uses not described in this catalog. Nuclear energy control systems, combustion systems, railroad systems, aviation systems, medical equipment, amusement machines, vehicles, safety equipment, and installations subject to separate industry or government regulations. Systems, machines, and equipment that could present a risk to life or property. Please know and observe all prohibitions of use applicable to the products. NEVER USE THE PRODUCTS FOR AN APPLICATION INVOLVING SERIOUS RISK TO LIFE OR PROPERTY WITHOUT ENSURING THAT THE SYSTEM AS A WHOLE HAS BEEN DESIGNED TO ADDRESS THE RISKS, AND THAT THE OMRON PRODUCTS ARE PROPERLY RATED AND INSTALLED FOR THE INTENDED USE WITHIN THE OVERALL EQUIPMENT OR SYSTEM. PROGRAMMABLE PRODUCTS OMRON shall not be responsible for the user's programming of a programmable product, or any consequence thereof. Disclaimers CHANGE IN SPECIFICATIONS Product specifications and accessories may be changed at any time based on improvements and other reasons. It is our practice to change model numbers when published ratings or features are changed, or when significant construction changes are made. However, some specifications of the products may be changed without any notice. When in doubt, special model numbers may be assigned to fix or establish key specifications for your application on your request. Please consult with your OMRON representative at any time to confirm actual specifications of purchased products. DIMENSIONS AND WEIGHTS Dimensions and weights are nominal and are not to be used for manufacturing purposes, even when tolerances are shown. PERFORMANCE DATA Performance data given in this catalog is provided as a guide for the user in determining suitability and does not constitute a warranty. It may represent the result of OMRON's test conditions, and the users must correlate it to actual application requirements. Actual performance is subject to the OMRON Warranty and Limitations of Liability. ERRORS AND OMISSIONS The information in this document has been carefully checked and is believed to be accurate; however, no responsibility is assumed for clerical, typographical, or proofreading errors, or omissions. 2012.7 In the interest of product improvement, specifications are subject to change without notice. OMRON Corporation Industrial Automation Company http://www.ia.omron.com/ (c)Copyright OMRON Corporation 2012 All Right Reserved. Mouser Electronics Authorized Distributor Click to View Pricing, Inventory, Delivery & Lifecycle Information: Omron: CS1W-CLK21-V1 3G8F7-CLK52-EV1 CVM1-CLK52 CS1W-SLK11 CS1W-CLK52-V1 CS1W-CLK53 CS1W-CLK13 CS1W-CLK23