Technical Catalogue Solid State Relays
Interface Relays
ABB STOTZ-KONTAKT GmbH 3
1SAC 1009 01 D0201
Solid-state relays
Terminal modules
Contents
Solid-state relays SIGMASWITCH®........................................................................................................................................ 5
Ordering details..................................................................................................................................................................................... 6
Technical data
R 111 / R 300 ......................................................................................................................................................................................... 10
Technical data
R 111 / R 115, HS-25/50, R 12x .................................................................................................................................................. 12
Technical data R 111 / R 115 / R 1100.................................................................................................................................... 13
Technical data R 311, HDS-50..................................................................................................................................................... 14
Derating curves, limiting overload characteristics,
dimension diagrams ............................................................................................................................................................................ 15
Technical data HDS R2 .................................................................................................................................................................... 17
Selection table for heat sinks
dimension diagrams ............................................................................................................................................................................... 18
Terminal modules .............................................................................................................................................................................. 21
Ordering details...................................................................................................................................................................................... 22
Technical data ........................................................................................................................................................................................ 24
4ABB STOTZ-KONTAKT GmbH
1SAC 1009 01 D0201
ABB STOTZ-KONTAKT GmbH 5
1SAC 1009 01 D0201
Solid-state relays
SIGMASWITCH®
Type Series 111/311
General features
Load side:
Single-phase devices:
Thyristors for AC 1 and AC 3 up to 660 V
AC and 125 A, with or without internal
RC circuit 3-phase devices:
Thyristors for AC 1 and AC 3 up to 530 V
AC and 50 A, with internal RC circuit
Electrical isolation by means of
optocoupler between control circuit and
load circuit
Zero voltage switch, radio interference-
suppressed
Screw mounting, snap-on mounting with
adapter for 35 mm top-hat rail to
DIN EN 50 022
Shock-hazard protection with additional
terminal shroud
Electrical connection:
Screw connection
Application
Contactless and wear-free switching of
AC and 3-phase loads up to cos PHI 0.5
Semiconductor three-phase contactors HDS
General features
Load side:
HDS R2: Triacs for AC 1 / AC 3 up to
460 V AC and 3.4 A with internal
overvoltage protection HDS-50:
Thyristors for AC 1 / AC 3 up to 530 V AC
and 50 A, with internal RC circuit and
overvoltage protection
Electrical isolation by means of
optocouplers between control circuit and
load circuit
Switch-position indication by LED
Control circuit protected against reverse
polarity
Zero voltage switch, radio interference-
suppressed
Snap-on mounting for 35 mm top-hat rail
to EN DIN 50 022
Integrated shock-hazard protection
Electrical connection: Screw connection
Integrated heat sink, ready-to-use
Application
Contactless and wear-free switching of
ohmic and inductive AC and three-phase
loads
General features
Load side:
Thyristors for AC 3 + AC 4 up to 460 V
AC and 10 A, AC 1 25 A with RC
circuit and overvoltage protection
Electrical isolation by means of inductive
transformers between control and load
circuit
Instantaneous switch to prevent unwanted
arcing-through of the thyristors
Control circuit protected against reverse
polarity
Switch position indicator LED
Screw mounting, snap-on mounting
with adapter for 35 mm top-hat rail to
EN DIN 50 022
Integrated shock-hazard protection
Electrical connection:
Screw or plug-in connection
Application
Contactless and wear-free switching of
ohmic and inductive AC and 3-phase
loads
SST 004 96 R
SST 073 98
SST 072 98
Type Series R 100
SST 07500
SST 07600
SST 07700
6ABB STOTZ-KONTAKT GmbH
1SAC 1009 01 D0201
SIGMASWITCH® Solid-state relays
Ordering details
R120/25
SST 072 98
RD112
SST 580 92
Device series R 12x
Thyristor units for R loads and general loads cos. ϕ 0.5 - 1
• Modern connection system using box terminals
• LED status indicator
Type Rated Rated Rated Order code Price Weight / Pack.
control circuit operating current piece unit
voltage voltage
UcUe Ie AC1 kg piece
R 120/25 3 ... 32 V DC 24 ... 280 V AC 25 A 1SAR 111 025 R 5102 0.090 1
R 122/50 4 ... 32 V DC 24 ... 660 V AC 50 A 1SAR 111 050 R 5107 0.090 1
R 122/90 4 ... 32 V DC 48 ... 660 V AC 90 A 1SAR 111 090 R 5107 0.090 1
R 122/125 4 ... 32 V DC 48 ... 660 V AC 125 A 1SAR 111 125 R 5107 0.090 1
Accessories for thyristor unit R 12x
Type Order code Price Weight / Pack.
piece unit
kg piece
Heat sink KK-120-1.4, 1.4 K/W a b 1SAR 118 014 R 0000 0.470 1
a Use heat transfer compound when mounting solid-state relays!
b Suitable for butt mounting, with clip for top-hat rail mounting
Device Series Rdxxx; DC switches
Type Rated Rated Rated Order code Price Weight / Pack.
control circuit operating current piece unit
voltage voltage
UcUe max Ie DC1 kg piece
RD 112 4 ... 32 V DC 100 V DC 12 A 1SAR 112 012 R 0210 0.100 1
RD 120 4 ... 32 V DC 100 V DC 20 A 1SAR 112 020 R 0210 0.100 1
RD 140 4 ... 32 V DC 100 V DC 40 A 1SAR 112 040 R 0210 0.100 1
RD 212 4 ... 32 V DC 200 V DC 12 A 1SAR 112 012 R 0211 0.100 1
RD 412 4 ... 32 V DC 400 V DC 12 A 1SAR 112 012 R 0212 0.100 1
RD 510 4 ... 32 V DC 500 V DC 10 A 1SAR 112 010 R 0213 0.100 1
ABB STOTZ-KONTAKT GmbH 7
1SAC 1009 01 D0201
R 111/25
R 1141
SST 281 92 R
SST 280 92 R
R 112/80
SST 004 96 R
SIGMASWITCH® Solid-state relays
Ordering details
Thyristor units for R loads and general loads (cos.ϕϕ
ϕϕ
ϕ 0.5-1).
with integrated RC circuit (R111/R115, R1041, R1042)
for ohmic and general loads with cos. ϕ 0.5 - 1
without integrated RC circuit (with increased surge current strength) R112 for ohmic loads
Type Rated Rated Rated Order code Price Weight / Packing
control circuit operating current piece unit
voltage voltage
UcUe Ie AC1 kg piece
R 111/10 3... 32 V DC 24...280 V AC 10 A GHV 111 0001 R 0001 0.100 1
R 111/25 3... 32 V DC 24...280 V AC 25 A GHV 111 0001 R 0002 0.100 1
R 111/45 3... 32 V DC 24...280 V AC 50 A GHV 111 0001 R 0003 0.100 1
R 111/08 3... 32 V DC 80...530 V AC 10 A GHV 111 0002 R 0001 0.100 1
R 111/20 3... 32 V DC 80...530 V AC 25 A GHV 111 0002 R 0003 0.100 1
R 111/40 3... 32 V DC 80...530 V AC 50 A GHV 111 0002 R 0005 0.100 1
R 111/90 3... 32 V DC 80...530 V AC 90 A GHV 111 0002 R 0006 0.200 1
R 111/120 3... 32 V DC 80...530 V AC 125 A GHV 111 0002 R 0007 0.200 1
R 112/40 4... 32 V DC 80...660 V AC 50 A GHV 112 0001 R 0003 0.100 1
R 112/80 4... 32 V DC 80...660 V AC 90 A GHV 112 0001 R 0004 0.200 1
R 115/10 90...280 V AC 24...280 V AC 10 A GHV 115 0001 R 0001 0.100 1
R 115/25 90...280 V AC 24...280 V AC 25 A GHV 115 0001 R 0002 0.100 1
R 115/45 90...280 V AC 24...280 V AC 50 A GHV 115 0001 R 0003 0.100 1
R 115/20 90...280 V AC 80...530 V AC 25 A GHV 115 0002 R 0003 0.100 1
R 115/40 90...280 V AC 80...530 V AC 50 A GHV 115 0002 R 0005 0.100 1
Triac units
R 1141 3... 32 V DC 24...280 V AC 10 A GHV 114 0001 R 0001 0.100 1
R 1142 3... 32 V DC 24...280 V AC 25 A GHV 114 0002 R 0001 0.100 1
Accessories for thyristor and triac units R111, R112, R115, R114.
Type Order code Price Weight / Packing
piece unit
kg piece
Quick-fastening plate GHR 110 1105 R 0001 0.045 1
Terminal shroud GHR 110 6605 P 0001 0.005 1
Heat sink with heat resistance 2.6 K/W aGHR 110 9401 P 0001 0.120 1
Heat sink with heat resistance 1.8 K/W aGHR 110 9401 P 0002 0.200 1
Heat sink with heat resistance 0.7 K/W
aGHR 110 9404 P 0001 0.650 1
KK-R111-2.1 Heat sink 2.1 K/W a b GHR 110 9402 P 0001 0.290 1
KK-R111-1.5 Heat sink 1.5 K/W
a b GHR 110 9405 P 0001 0.420 1
KK-R111-0.7 Heat sink 0.7 K/W a b GHR 110 9406 P 0001 1.020 1
KK-R111-0.5 Heat sink 0.5 K/W a b GHR 110 9407 P 0001 1.300 1
R 1591, protective circuit 230 V AC GHR 159 0001 R 0002 0.020 1
R 1592, protective circuit 400 V AC GHR 159 0002 R 0002 0.020 1
EMV - 100 EMC filter, single-phase GHR 110 0000 R 0001 0.100 1
Heat-conductive foil TP01 GHR 110 9500 P 0001 0.001 1
aUse heat transfer compound when mounting solid-state relays!
bSuitable for butt mounting, with clip for top-hat rail mounting
8ABB STOTZ-KONTAKT GmbH
1SAC 1009 01 D0201
SIGMASWITCH® Solid-state relays
Ordering details
HS 25
SST 028 97
HS 50
SST 001 96 R
SST 073 98
HS 65
SST 075 00 SST 076 00 SST 077 00
R300.25
R100.35
R100.12
Semiconductor types R100 / R300
Compact design with integrated heat sink, LED indication, integrated protective circuit
Mounting for DIN-rail or on mounting plate
Type Rated Rated Rated Order code Price Weight / Packing
control circuit operating current piece unit
voltage voltage
UcUeIe AC1 kg piece
Semiconductor relay (triac), 1 phase, zero voltage switching, max. 12 A
R100.12 4-32 V DC 24-280 V AC 12 A 1SAR 114 012 R8202 0.250 1
Semiconductor relay (thyristor), 1 phase, standard switching, max. 25 A
R100.25 replace R102.43!
R100.25 4-32 V DC 48-660 V AC 25 A 1SAR 113 025 R8207 0.250 1
Semiconductor relay (thyristor), 1 phase, zero voltage switching, max. 35 A, width: 45 mm
R100.35 4-32 V DC 48-660 V AC 35 A 1SAR 111 035 R8207 0.490 1
"Self guard" Semiconductor relay (thyristor), with current monitor and indication for service,
zero voltage switching, max. 35 A, width: 45 mm
R100.35 SG 4-32 V DC 48-660 V AC 35 A 1SAR 111 035 R9207 0.490 1
Semiconductor relay (thyristor), 3 phase, zero voltage switching, max. 3 x 25 A, width: 90 mm
R300.25 4-32 V DC 48-660 V AC 3x25 A 1SAR 131 025 R8207 0.940 1
HS 25 4 ... 32 V DC 12...280 V AC 25 A GHV 111 0011 R 0002 0.260 1
HS 25 4 ... 32 V DC 45...530 V AC 25 A GHV 111 0012 R 0003 0.260 1
HS 50 3 ... 32 V DC 80...530 V AC 50 A GHV 111 0012 R 0005 0.520 1
HS 50-AC 90...280 V AC 80...530 V AC 50 A GHV 115 0012 R 0005 0.520 1
HS 50-H 4 ... 32 V DC 80...660 V AC 50 A GHV 112 0011 R 0003 0.520 1
HS 90/0.7 3 ... 32 V DC 80...530 V AC 90 A GHV 111 0022 R 0006 1.120 1
HS 125/0.7 3 ... 32 V DC 80...530 V AC 125 A GHV 111 0022 R 0007 1.120 1
HS 125/0.5 3 ... 32 V DC 80...530 V AC 125 A GHV 111 0032 R 0007 1.400 1
HS 45 4 ... 32 V DC 48...660 V AC 45 A 1SAR 111 045 R 6107 0.260 1
HS 65 4 ... 32 V DC 48...660 V AC 65 A 1SAR 111 065 R 6107 0.260 1
HS 25 Compact semiconductor switch (25 A at 40 °C) with LED indicator for top-hat rail mounting
HS 50 Semiconductor relay, mounted ready-to-use on heat sink (1.5 K/W), complete with terminal
shroud, thyristor and clip for top-hat rail mounting (28 A at 45 degrees C)
HS 90/0.7 Semiconductor relay, mounted ready-to-use on heat sink (0.7 K/W), complete with terminal
shroud, varistor and clip for top-hat rail mounting (62 A at 45 degrees C)
HS 125/0.7 Semiconductor relay, mounted ready-to-use on heat sink (0.7 K/W), complete with terminal
shroud, varistor and clip for top-hat rail mounting (62 A at 45 degrees C)
HS 125/0.5 Semiconductor relay, mounted ready-to-use on heat sink (0.5 K/W), complete with terminal
shroud, varistor and clip for top-hat rail mounting (80 A at 45 degrees C)
HS 45 45 A at 25 degrees C ambient temperature, new design with status LED and box terminals
HS 65 65 A at 25 degrees C ambient temperature, new design with status LED and box terminals
ABB STOTZ-KONTAKT GmbH 9
1SAC 1009 01 D0201
SST 003 96 R
SST 014 93
R 311/20
HDS-50
SST 002 96 R
HDS-R2
SIGMASWITCH® Solid-state relays
Ordering details
Dimension diagrams
Dimension diagrams
HS 90 / 0.7, KK-111-0.7
HS 125 / 07
Dimensions:
W x H x D = 72 x 75 x 124 mm
HS 125 / 0.5, KK-111-0.5
Dimensions:
W x H x D = 120 x 100 x 135 mm
HS 45 / HS 65
Dimensions in inches and (mm)
R 12x
Dimensions in inches and (mm)
Thyristor units, 3-phase, for R loads (and general loads up to cos PHI 0.5 - 1)
R 311/20 3... 32 V DC 45 ... 530 V AC 25 A GHV 311 0001 R 0001 0.450 1
R 311/40 3... 32 V DC 45 ... 530 V AC 50 A GHV 311 0001 R 0002 0.450 1
R 315/40 90...280 V AC 45 ... 530 V AC 50 A GHV 315 0001 R 0002 0.450 1
HDS semiconductor three-phase contactors (mounted ready-to-use, suitable for butt mounting)
HDS R2 17... 32 V DC 400 V AC 3.4 A GHR 302 0004 R 0001 0.270 1
HDS-50 3... 32 V DC 45 ... 530 V AC 50 A GHV 311 0011 R 0002 1.500 1
HDS-50-AC 90...280 V AC 45 ... 530 V AC 50 A GHV 315 0011 R 0002 1.500 1
HDS-50 semiconductor relay R311/40, mounted ready-to-use on heat sink (0.8 K/W), complete with
terminal shroud, varistors and clip for top-hat rail mounting (3 x 24 A at 45°C)
Accessories for 3-phase thyristor units R311
Type Order code Price Weight / Pack.
piece unit
kg piece
Quick-fixing plate GHR 310 1105 R 0001 0.050 1
Terminal shroud GHR 310 6605 P 0001 0.050 1
Heat sink with heat resistance 0.8 K/W aGHR 310 9401 P 0001 1.000 1
EMV - 300 EMC filter three-phase GHR 310 0000 R 0001 0.100 1
Heat conductive foil TP03 GHR 310 9500 P 0001 0.005 1
a Use heat transfer compound when mounting solid-state relays!
10 ABB STOTZ-KONTAKT GmbH
1SAC 1009 01 D0201
Solid-state relays, R 100/R 300
Technical data
Output data Unit R100.12 R100.25 R100.35 R300.25
Contact element TRIAC Thyristoren Thyristoren Thyristoren
Operating voltage range Ue (Veff max) V AC 24-280 48-660 48-660 48-660
Periodic peak off-state voltage (VSpitze) V ss 600 1200 10001) 1200
Thermal continuous current A 12 25 35 3x 25
Operating frequency Hz 47-80 47-80 47-80 47-80
Max. off-state leakage current
(at Vmax and T=25°C) mA 15 20 4 20 per phase
Minimal load current mA eff 50 100 100 100 per phase
Max. surge current ITSM (t=20ms) A 100 7 50 750 500
Max. overcurrrent (t =1s) A 30 145 145 145
Max. load integral i2dt (t=10 ms) A2s 312 1250 1260 1260
Conducting-stage voltage at I max and
T= 25° C (Vpeak) V 1,6 1,6 1,6 1, 6
Permissible rate of voltage rise du/dt V/µs 200 500 500 500
cos ϕ (nullspannungsschaltend) >0,5-1 Quick-act. switching >0,5-1 >0,5-1
Thermal resistance
Rth barrier junction/ambient air °C/W 4,9 2,5 3,78 1
Suppressor circuit (RC-filter, varistor) yes yes yes yes
Input data
Control voltage V DC 4-32 4-32 4-32 4-32
Conducting-stage voltage V DC 1 1 1 1
Input impedance k3333
Input current max. (bei Vmax) mA 12 12 12 1 0
Turn-on time ms 0,5 max. period <100 µs 0,5 max. period 0,5 max. period
Turn-off time ms 0,5 max. period 0,5 max. period 0,5 max. period 0,5 max. period
General datadata
datadata
data
Weight g 250 250 490 940
Max. wire range
Input terminals mm22222
Output terminals mm22 2 5,6 2
Operating temperature range °C -20 up to +80
Storage temperature range °C -40 up to +100
Test voltage V 4000
Electric strength V 2500
Capacitance pF 8
Material casing Self-extinguishing (UL 94 V0)
base Aluminium
1) Peak voltage 1200 V, relay protected up to 1100 V +/- 10 %
ABB STOTZ-KONTAKT GmbH 11
1SAC 1009 01 D0201
Solid-state relays, R 100/R 300
Technical data
Block diagrams
R100.12 (TRIAC) R 100.35
(Thyristors, quick-action switching)
R 300.25
(Thyristors, no-voltage switching)
R 100.12 (TRIAC) R 100.25 R 100.35-SG
R 300.25
R 100.12
R 100.25 R 100.35-SG R 300.25 R 100/R 300
Reduction Curves
Dimension diagrams
R 100.25
(Thyristors, no-voltage switching)
12 ABB STOTZ-KONTAKT GmbH
1SAC 1009 01 D0201
Solid-state relays, R 111/115 / HS-50, R 12x, HS 25
Technical data
Dimension diagrams
Dimension diagram R111 / R112 / R115 / R 100 / RDxxx
Solid-state relay
Type Series R110 without terminal
shroud with terminal
shroud
ABB 86 6243
Connection screws with inch thread
Control circuit: 6-32" Load circuit: 8-32"
Dimension diagram HS-25
Dimension diagrams
F
F
37.1 F
F
79.4
F
F
90.0
(Dimensions in mm)
Output data Unit HS 25
R111/10 R111/25 R111/45 R111/08 R111/20 R111/40 R120/25 R122/50 R122/90 R122/125
R115/10 R115/25 R115/45 R115/20 H S-50
Rated operating voltage UeV AC 230 / 240 230 / 240 400 / 480 230/240 600 600 600
Operating voltage range V AC 12 ... 280 24 ... 280 80 ... 530 24 ...280 48 ...660 48 ...660 48 ...660
Periodic peak off-state voltage V pp 600 650 1200 600 1200 1200 1200
Operating frequency Hz 47 ... 63 47 ... 63 47 ... 63 47 ... 63 47 ... 63 47 ... 63 47 ... 63
Thermal cont. current Ie(AC 1) A 30 10 25 50 10 25 50 25 50 90 125
Minimum load current mA AC 150 40 40 40 40 40 40 15 15 15 15
Max. surge current A AC 625 160 250 600 160 250 600 250 625 1200 1200
ITSM( t = 20 m s) (16.6 ms)
Max. overcurrent (t = 1 s) A AC 50 80 175 50 8 0 175
Max. voltage drop V AC 1.6 1.6 1.6 1.6 1.6 1.6 1.5 1.6 1.6 1.6 1.6
Max. load integral A2s 1620 130 310 1800 130 310 1800 260 1620 6000 12700
i2dt (t = 1 0 ms ) (8.3 ms)
Leakage current in OFF state mA 0.1 10 10 10 10 10 10 10 10 1 0 10
Perm. rate of voltage rise du/dt V/µs 500 500 500 500 500 500 500 500 500 500 500
Perm. rate of current rise di/dt A/µs 100 100 100 100 100 100 100 100 100 100 100
Thermal resistance °C/W 2 1.25 0.65 2 1.25 0.65 1.02 0.63 0.29 0.22
Max. heat loss W 4 8 16 40 80 16 40 80
RC circuit +µF 33+0.033 47+0.022
Input data HS Series R111 Series R115 Series R12x
Control voltage V 4...32 V DC 3 ... 32 V DC 90 ... 280 V AC 3...32 V DC 4...32 V DC
Dielectric strength V -32 V DC -32 V DC 310 V AC -32 V AC
Minimum voltage for signal "1" V 4 V DC 3 V DC 90 V AC 4 V DC
Max. voltage for signal "0" V 1 V DC 1 V DC 10 V DC 1 V DC
Input impedance kΩ≥1.5 44
Input current mA Typ. 5 mA 3 mA (5 VDC) 3 mA (110 V AC) Max. 30 mA
(5 V DC) 16 mA (24 V AC) 6 mA (240 V AC) Typical 17 mA
Turn-on time f = 50 Hz ms 10 20 10
Turn-off time f = 50 Hz ms 10 20 10
Test voltage kV 4000 V
Coupling capacitance I/O pF <8 <8
Creepage distance I/O mm >8
Ambient temperature range °C -30 ... +80 -40 ... +80
Storage temperature range °C -40 ... +100 -40 ... +80
Utilisation categories
(DIN 40040) Humidity: FShock and vibration: VClimate: Z
ABB STOTZ-KONTAKT GmbH 13
1SAC 1009 01 D0201
ABB 86 6754 /x
SST 207 95 M
*
*
*
SST 238 93 S
SST 238 93 S1 S
L1
N
2
1
U
e
U
c
A1
A2
Output data
Rated operating voltage Ue
Operating voltage range
Periodic peak off-state voltage
Operating frequency
Thermal continuous current Ie(AC 1)
Minimum load current
Max. surge current ITSM (t = 20 ms)
Max. overcurrent (t = 1 s)
Max. voltage drop
Max. load integral
i2dt (t = 10 ms)
Leakage current in OFF state
Permissible rate of voltage rise du/dt
Permissible rate of current rise di/dt
Thermal resistance
Max. heat loss
RC circuit
Input data
Control voltage
Dielectric strength
Minimum voltage for signal "1"
Max. voltage for signal "0"
Input impedance
Input current
Turn-on time f = 50 Hz
Turn-off time f = 50 Hz
Test voltage
Coupling capacitance I/O
Creepage distance I/O
Ambient temperature range
Storage temperature range
Utilisation categories
(DIN 40040)
R111/90 R111/120 R112/40 R112/80 R1141 R1142
V AC
V AC
Vpp
Hz
A
mA AC
A AC
A AC
V AC
A2s
mA
V/µs
A/µs
°C/W
W
+µF
V DC
V DC
V DC
V DC
k
mA
ms
ms
kV
pF
mm
400/480 530/600 230/ 240
80...530 80...660 24...280
1200 1200 650
47 - 63 47 - 63 47 - 63
125
40
1750
360
1.7
12700
10
500
50
0.25
160
10
40
90
30
1.6
40
10
250
10
2.1
16
47 + 0.022 33 + 0.033
3...32 V DC (R112: 4...32 V DC)
–32 V DC
3 V DC (R112: 24 V DC)
1 V DC
1.5
4 mA (5 V DC), 17 mA (24 V DC) (R112: 25 mA)
10
10
Input-output: 4; input-baseplate: 2.5; output baseplate: 2.5
< 8pF
> 8
-30...+ 80 °C
-40...+ 100 °C
Humidity: F, Shock and vibration: V, Climate: Z
90
40
1200
360
1.7
6000
10
500
50
0.28
98
47 + 0.022
50
40
625
175
1.7
1620
5
500
50
0.63
55
90
40
1200
360
1.7
6000
5
500
50
0.28
98
25
40
250
80
1.6
310
10
500
100
1.40
40
33 + 0.033
Solid-state relays
Type Series R 111 / R 112 / R 1100
Technical data
Unit
Heat sink GHR 110 9405 P 0001
Dimension diagram HS-50
Basic circuit diagrams R112, R111/115, R1100
Wiring diagram
* Recommended protective circuit in installations with high peak interference voltages
(already integrated in the case of HS-50)
R 1100
R 111 / R 115
R 112
Dimensions in mm
14 ABB STOTZ-KONTAKT GmbH
1SAC 1009 01 D0201
Output data
Rated operating voltage Ue
Operating voltage range
Periodic peak off-state voltage
Operating frequency
Thermal continuous current Ie(AC 1)
Minimum load current
Max. surge current ITSM (t = 20 ms)
Max. overcurrent (t = 1 s)
Max. voltage drop
Max. load integral
i2dt (t = 10 ms)
Leakage current in OFF state
Permissible rate of voltage rise du/dt
Permissible rate of current rise di/dt
Thermal resistance
Max. heat loss
RC circuit
Input data
Control voltage
Dielectric strength
Minimum voltage for signal "1"
Max. voltage for signal "0"
Input impedance
Input current
Turn-on time f = 50 Hz
Turn-off time f = 50 Hz
Test voltage
Coupling capacitance I/O
Creepage distance I/O
Ambient temperature range
Storage temperature range
Utilisation categories
(DIN 40040)
Solid-state relays, R 311, 3-phase
Semiconductor three-phase contactor HDS-50
Technical data
R 311/20 R 311/40 R 315/40
HDS-50 HDS-50-AC
Unit
V AC
V AC
Vpp
Hz
A
mA AC
A AC
A AC
V AC
A2s
mA
V/µs
A/µs
°C/W
W
+µF
V DC
V DC
V DC
V DC
k
mA
ms
ms
kV
pF
mm
400/480
45 ... 530
1200
25 - 65
Dimension diagram R 311 /315
Dimensionsin mm
Heat sink GHR 310 9401 P0001
3
5.3
20
54
22
73.5
20
47.6
10
10
30 44.5
L1 L2 L3
T2T1 T3
104
92
A1+ A2
SST 206 95 M
SST 208 95 M
25
50
300
80
1.6
450
10
500
50
1.4
105
47 + 0.022
50
50
500
175
1.6
1250
10
500
50
0.65
170
47 + 0.022
50
50
500
175
1.6
1250
10
500
50
0.65
170
47 + 0.022
3 ... 32 V DC
- 32 V DC
> 3 V DC
< 1 V DC
>1.5
< 4 mA (5 V DC), < 17 mA (24 V DC)
< 10
< 10
Input-output: 4; input-baseplate: 2.5; output baseplate: 2.5
< 8pF
> 8
- 30 ... + 80 °C
- 40 ... + 100 °C
90 ... 280 V AC
310 V AC
> 90 V AC
< 10 V AC
> 44
< 3 mA (110 V AC),
< 6 mA (240 V AC)
< 20
< 20
Humidity: F, Shock and vibration: V, Climate: Z
Dimension diagram HDS-50 / HDS-50-AC
Dimensions in mm
145
85
114
ABB STOTZ-KONTAKT GmbH 15
1SAC 1009 01 D0201
R1141 R111/25 R115/25 R311/20 HS 25
R111/20 R115/20 R1142/2
Limiting overload characteristics
Derating curves
Dimension diagrams
Dimensions in mm
SST 08391 M
ABB 86 6755
GHR 1109401 P1 and P2 Heat sink
GHR 1109404 P1, length 100 mm
Heat sink
GHR 1109401 P2 GHR 1109401 P1
SST 233 93 K
SST 231 93 K
R111/10 R115/10
R111/08 R115/10
SST 236 93 K
SST 235 93 K
SST 233 93 K
SST 234 93 K
I = rms value of operating current
TA= Ambient temperature Thermal resistance of the heat sink:
a = Self-cooling f = HS 25
b = 5.0 K/W
c = 2.6 K/W
d = 1.7/1.8 K/W
e = 0.7 K/W
0 20 40 60 80 100 °C
Ambient temperature T
A
Operating current I
A
10
7,5
5
2,5
0
1
2
3 4 5
0 20 40 60 80 100 °C
Ambient temperature T
A
Operating current I
A
30
25
20
15
10
5
0
1
2
3
456
Peak current
Overcurrent duration
Peak current
Overcurrent duration
Peak current
Overcurrent duration
0 20 40 60 80 100 °C
Ambient temperature T
A
Operating current I
A
10
7,5
5
2,5
0
1
2
3 4 5
Solid-state relays
Derating curves, Limiting overload characteristics
Dimension diagrams
A surge current near to the max. surge current influences the expected service life of the unit and is therefore permissible only in exceptional
cases, e.g. in the event of a short-circuit or malfunction.
Periodic surge currents may not exceed approx. 50 % of the max. surge current.
16 ABB STOTZ-KONTAKT GmbH
1SAC 1009 01 D0201
I
Peak current
Overcurrent duration
R111/90 R112/80 R111/120
Dimension diagrams
Dimensions in mm (height including top-hat rail)
Heat sink KK-R111-1.5
GHR 110 9405 P 0001
Derating curves
Limiting overload characteristics
I = rms value of operating current
TA= Ambient temperature Thermal resistance of the heat sink:
a = Self-cooling
b = 5.0 K/W
c = 2.6 K/W
d = 1.7/1.8 K/W
e
= 0.7 K/W
A surge current near to the max. surge current influences the expected service life of the unit and is therefore permissible only in exceptional
cases, e.g. in the event of a short-circuit or malfunction.
Periodic surge currents may not exceed approx. 50 % of the max. surge current.
SST 232 93 K
Heat sink
GHR 310 9401 P0001
SST 207 95 M
SST 209 95 M
HS-50 R315/44 HDS-50-AC
R111/45 R115/45 R111/40
R112/40 R311/40 HDS-50
SST 215 95 K
SST 217 95 K
SST 236 93 K
R 1591, R 1592
Protective circuits
Width:
11.25 mm
Operating current
Ambient temperature
Operating current
Ambient temperature
Operating current
Ambient temperature
Peak current
Overcurrent duration
I
Peak current
Overcurrent duration
Solid-state relays, R 1100
Derating curves, Limiting overload characteristics
Dimension diagrams
139
85
114
SST 221 95 M
ABB STOTZ-KONTAKT GmbH 17
1SAC 1009 01 D0201
75
99
53,5
+
+
24VDC
L1 L2 L3
T1 T2 T3
ABC
HDS
Type HDS R2
Rated operating voltage UeV AC 230 / 400
Operating voltage range V AC 24...460
Peak off-state voltage AC V 800
Max. operating current I e (AC3) A 3.4
Thermal continuous current (AC1) A 3.4
Switching capacity ckW 1.5
Max. surge current (10 ms) ITSM A 120
Max. load integral
i2dt b A2s72
Max. voltage drop UTVrms 2
Max. residual current IDRM mA 1.7
Minimum load current IHmA 10
Permissible rate of current rise di/dt A/µs 100
Permissible rate of voltage rise du/dt V/µs 200
Control voltage UcV D 24
High-signal V DC 17...32
Low-signal V DC 8
Control current mA 16
Input impedance k1.5
On delay ms 10
Off delay ms 10
Test voltage
Input-output / heat sink kVrms 2.5
Input-output kVrms 4
Operating temperature range °C -20...+55
Storage temperature range °C -25...+85
a
At Tu = 45 °C
b Pulse duration 10 ms, Tvj = 125 °C.
c At cos ϕ 0.75; device is not suitable for reversing circuits!
Semiconductor three-phase contactor HDS R2
Technical data
Dimensions
24VDC
+
L1
L2
L3
N
SST 215 93 S
SST 216 93 K1+2
Derating curve
SST 217 93 M
Remarks
Wiring diagram
10 20 30 40 50 60 70
6
5
1
2
3
4
A
Ambient temperature C
18 ABB STOTZ-KONTAKT GmbH
1SAC 1009 01 D0201
Selection table for solid-state relays / heat sinks
Dimension diagrams
Dimensions
Type Dimensions
BTH
KK-R111-2.1 51 65 65
KK-111-1.5 45 65 97
KK-R120-1.4 45 77 97
Type Dimensions
BTH
KK-R120-1.4 45 77.5 114
with mounted
solid-state relay R12x
3-phase solid-state relays for general loads (cos-Phi 0.5-1)
Type Remarks Max. thermal continuous current per phase,
without/with heat sink, at ambient temperature
Self-cooling KK 0.8 K/W
25 °C 45 °C 25 °C 45 °C
R 311/20 Zero voltage switch 5 A 4 A 22 A 18 A
R 311/40 Zero voltage switch 6 A 4 A 28 A 24 A
R 315/40 Zero voltage switch.
AC-operation
6 A 4 A 28 A 24 A
Dimensions in mm
Single-phase solid-state relays for general loads (cos. Phi 0.5-1)
Type Remarks Max. thermal continuous current without/with heat sink, at ambient temperature
Self-cooling KK 2.1 K/W KK1.5 K/W KK0.7 K/W KK 0.5 K/W
25 °C 45 °C 25 °C 45 °C 25 °C 45 °C 25 °C 45 °C 25 °C 45 °C
R 111/10 Zero voltage switch 5 A 4 A 8 A 6 A 10 A 8 A 10 A 10 A 10 A 10 A
R 111/08 Zero voltage switch 5 A 4 A 8 A 6 A 10 A 8 A 10 A 10 A 10 A 10 A
R 115/10 Zero voltage switch.
AC-operation
5 A 4 A 8 A 6 A 10 A 8 A 10 A 10 A 10 A 10 A
R 1141 Zero voltage switch, triac 5 A 4 A 8 A 6 A 10 A 8 A 10 A 10 A 10 A 10 A
R 111/25 Zero voltage switch 5 A 4 A 16 A 13 A 22 A 18 A 25 A 23 A 25 A 25 A
R 111/20 Zero voltage switch 5 A 4 A 16 A 13 A 22 A 18 A 25 A 23 A 25 A 25 A
R 115/25 Zero voltage switch.
AC-operation
5 A 4 A 16 A 13 A 22 A 18 A 25 A 23 A 25 A 25 A
R 115/20 Zero voltage switch.
AC-operation
5 A 4 A 16 A 13 A 22 A 18 A 25 A 23 A 25 A 25 A
R 120/25 Zero voltage switch,
new design
10 A 8 A 25 A 25 A
R 1142 Zero voltage switch, triac 5 A 4 A 16 A 13 A 22 A 18 A 25 A 23 A 25 A 25 A
R 111/45 Zero voltage switch 6 A 4 A 18 A 16 A 32 A 28 A 45 A 37 A 50 A 50 A
R 111/40 Zero voltage switch 6 A 4 A 18 A 16 A 32 A 28 A 45 A 37 A 50 A 50 A
R 112/40 Zero voltage switch, R-loads 6 A 4 A 18 A 16 A 32 A 28 A 45 A 37 A 50 A 50 A
R 115/45 Zero voltage switch.
AC-operation
6 A 4 A 18 A 16 A 32 A 28 A 45 A 37 A 50 A 50 A
R 115/40 Zero voltage switch.
AC-operation
6 A 4 A 18 A 16 A 32 A 28 A 45 A 37 A 50 A 50 A
R 122/50 Zero voltage switch,
new design
10 A 8 A 40 A 35 A
R 111/90 Zero voltage switch 8 A 7 A 25 A 20 A 35 A 30 A 71 A 62 A 90 A 77 A
R 112/80 Zero voltage switch, R-loads 8 A 7 A 25 A 20 A 35 A 30 A 71 A 62 A 90 A 77 A
R 122/90 Zero voltage switch,
new design
10 A 8 A 45 A 40 A
R 111/120 Zero voltage switch 8 A 7 A 25 A 20 A 35 A 30 A 71 A 62 A 95 A 80 A
R 122/125 Zero voltage switch,
new design
10 A 8 A 50 A 45 A
ABB STOTZ-KONTAKT GmbH 19
1SAC 1009 01 D0201
Notes
20 ABB STOTZ-KONTAKT GmbH
1SAC 1009 01 D0201
ABB STOTZ-KONTAKT GmbH 21
1SAC 1009 01 D0201
Terminal modules
SST 037 95 R
SST 002 99 R
Interface relays are electromechanical and electronic input and output modules for electrical
isolation, level adaptation, interference suppression or signal amplification between control
system and process.
Housing material: alphamide
Snap-on mounting on 35mm top-hat rail or mounting on C-rails (only series R1500/R1600)
Status indication by LED
Rated insulation voltage UI: 250/380V AC (Group C)
Conductor connection single-core or stranded, max 2x1.5mm2
Installation position: any
Enclosure: Housing IP40, terminals IP20
Electrical isolation by optocoupler or relay
Temperature range: Operational: -20 ... + 55 °C
Storage: -40 ... + 80 °C
Type Series R 1000 Type Series R1500/R1600
- Housing width: 6.2 mm - Housing width: 11.25 mm
- Electromechanical: 1 NO, 1 changeover - Electromechanical: 1 NO, 1 NC, 2 NO,
2 NC, 1 ch., 2 ch.
- Electronic: R1084 Transistor, - Electronic: R1584/R1585
100 mA Transistor, 100 mA
R1062 TRIAC, 0.5 A R1552, R1662 TRIAC
R1064 Transistor, 1 A R1664 Transistor, 3 A
R1048 MOSFET, 2 A, R1647/R1648 MOSFET,
Short-circuit-proof Short-circuit-proof
Approvals and Certifications
UL CSA GL
R1000 Applied for Applied for In preparation
R1500/R1600 Awarded Awarded Awarded
22 ABB STOTZ-KONTAKT GmbH
1SAC 1009 01 D0201
SIGMA® terminal modules
Type Series R 1500 S / R 1600
Ordering details
SST 268 92 R
SST 268 92 R SST 268 92 R
R 1561
R 1584
R 1564
Input modules
Type Rated Rated Rated Order code Price Weight / Pack.
contr. circuit operating current
Product No. (add the code
piece unit
voltage voltage À
number for connection type
UcUeIe max.
to order code if necessary)
kg piece
Input stage (transistor) + protective circuit
R 1584 24 V DC 24 V DC 10 0mA GHR 158 0004 R 0002 0.020 1/10
R 1585 230 V AC/DC 24 V DC 1 00 mA GHR 158 0005 R 0002 0.020 1/10
Input relay, 1 NO contact (contact material Ag Au 5µ)
R 1571 24 V AC/DC 230 V AC/DC* 3 A GHR 157 4001 R 0002 0.020 1/10
230 V AC/DC 230 V AC/DC* 3 A GHR 157 4051 R 0002 0.020 1/10
Input relay, 1 NC contact (contact material Ag Au 5µ)
R 1571 24 V AC/DC 230 V AC/DC* 3 A GHR 157 4101 R 0002 0.020 1/10
230 V AC/DC 230 V AC/DC* 3 A GHR 157 4151 R 0002 0.020 1/10
*DC rated switching capacity, see Technical data
3-channel interface relay (1 changeover contact, 1 changeover contact, 2 NO contacts
R 1530 24 V DC 230 V AC/DC* 6 A GHR 153 0001 R 0001 0.1 1
and
230 V AC
Output modules
Output relay, 1 NO contact
R 1561 24 V DC 230 V AC/DC* 5 A GHR 156 1001 R 0002 0.020 1/10
R 1561+RC 24 V DC 230 V AC/DC* 5 A GHR 156 0001 R 0002 0.022 1/10
R 1561 24 V AC/DC 230 V AC/DC* 5 A GHR 156 9001 R 0002 0.020 1/10
Univ. current
60 V AC/DC GHR 156 9021 R 0002 0.020 1/10
110 V AC/DC GHR 156 9041 R 0002 0.020 1/10
230 V AC/DC GHR 156 0051 R 0002 0.020 1/10
R 1561 24V DC 230 V AC/DC* 5 A GHR 156 8001 R 0002 0.020 1/10
Low Power
Output relay, 1 NC contact
R 1561 24 V DC 230 V AC/DC* 5 A GHR 156 1111 R 0002 0.020 1/10
R 1561+RC 24 V DC 230 V AC/DC* 5 A GHR 156 0111 R 0002 0.020 1/10
R 1561 24 V AC/DC 230 V AC/DC* 5 A GHR 156 9101 R 0002 0.020 1/10
Univ. current
60 V AC/DC GHR 156 9121 R 0002 0.020 1/10
110 V AC/DC GHR 156 9141 R 0002 0.020 1/10
230 V AC/DC GHR 156 0101 R 0002 0.020 1/10
Connection type: Control side Load side
Screw Screw 2
Plug Screw 4
Output relay, 2 NO contacts, 2 NC contacts or 1 changeover contact
R 1551 2S 24 V DC 230 V AC/DC* 4 A GHR 155 1201 R 0002 0.050 1
R 1551 24 V DC 230 V AC/DC* 4 A GHR 155 1301 R 0002 0.050 1
R 1551 1W 24 V DC 230 V AC/DC* 6 A GHR 155 1501 R 0002 0.050 1
Output relay, 1 or 2 changeover contacts, universal current
R 1541 1W 24 V DC/AC 230 V AC/DC* 4 A GHR 154 1501 R 0002 0.050 1
R 1541 1W 230 V DC/AC 230 V AC/DC* 4 A GHR 154 1601 R 0002 0.050 1
R 1542 2W 24 V DC/AC 230 V AC/DC* 2 A GHR 154 2501 R 0002 0.050 1
R 1542 2W 230 V DC/AC 230 V AC/DC* 2 A GHR 154 2601 R 0002 0.050 1
*DC rated switching capacity, see Technical data
Output stage (triac)
R 1552 230 V AC 400 V AC 1 A GHR 155 2052 R 0002 0.020 1
R 1662 24 V DC 230 V AC 3 A GHR 166 0002 R 0002 0.048 1
Output relay (Mosfet) short-circuit-proof output
R 1647 24 V DC 24 V DC 4 A GHR 164 0007 R 0002 0.048 1
R 1648 24 V DC 60 V DC 3 A GHR 164 0008 R 0002 0.048 1
Output relay (transistor)
R 1664 24 V DC 60 V DC 3 A GHR 166 0004 R 0002 0.048 1
Protective circuits for protecting electronic relay (RC + varistor)
R 1591 - 230 V AC a-GHR 159 0001 R 0002 0.020 1/10
R 1592 - 400 V AC b-GHR 159 0002 R 0002 0.020 1/10
a Max: 280 V AC, residual current 7 mA b Max. 440 V AC, residual current 12 mA
ABB STOTZ-KONTAKT GmbH 23
1SAC 1009 01 D0201
SIGMA® terminal modules - compact design
Type series R 1000, overall width 6.2mm
Ordering details
SST 002 99
SST 002 99
Overall width only: 6.2mm
Same space requirement as a standard terminal block
Electrical isolation by means of relay or optocoupler
Simplification of wiring through plug-in potential jumpers for A2 and ground of the
switching output in addition to the screw connections
Status indication by LED
Ultra-modern product technology, latest design
Certifications for worldwide use have been applied for or are in preparation (UL, CSA, GL)
Type Rated Rated Rated Order code Price Weight / Pack.
control circuit operating current piece unit
voltage voltage
UcUeIe max. kg piece
R 1061 electromechanical interface relay, 1 NO contact
R 1061 24V AC/DC 230V AC/DC 3 A GHR 106 9001 R0001 1/10
R 1061 115V AC/DC 230V AC/DC 3 A GHR 106 9041 R0001 1/10
R 1061 230V AC/DC 230V AC/DC 3 A GHR 106 9051 R0001 1/10
R 1041 electromechanical interface relay, 1 changeover contact
R 1041 24V AC/DC 230V AC/DC 3 A GHR 104 1501 R0001 1/10
R 1041 115V AC/DC 230V AC/DC 3 A GHR 104 1701 R0001 1/10
R 1041 230V AC/DC 230V AC/DC 3 A GHR 104 1601 R0001 1/10
R 1084 electronic interface relay with transistor output and electrical isolation by optocoupler
R 1084 24V DC 5-50V DC 100 mA GHR 108 0004 R0001 1/10
R 1064 electronic interface relay with transistor output and electrical isolation by optocoupler
R 1064 24V DC 5-50V DC 1 A GHR 106 0004 R0001 1/10
R 1062 electronic interface relay with TRIAC output and electrical isolation by optocoupler
R 1062 24V DC 12-250V AC 0.5 A GHR 106 0002 R0001 1/10
R 1048 short-circuit-proof electronic interface relay with MOSFET output and electrical isolation
by optocoupler
R 1048 24V DC 5-50V DC 2 A GHR 104 0008 R0001 1/10
Plug-in potential jumpers
P-1010 10-pin potential jumper GHR 100 0010 R0001 1/10
P-1024 24-pin potential jumper GHR 100 0024 R0001 1/10
SIGMA® Terminal module R 1530
Multi-channel interface relay in special design
Two independent output channels for signal amplification (ohmic: 6 A AC)
One checkback channel (1 ch.)
Overall width: 27 mm
Type Rated Rated Rated Order code Price Weight / Pack-
control circuit operating current piece unit
voltage voltage
UcUeIe max. kg piece
R 1530 3-channel, electromechanical interface relay (1 ch. contact, 1 ch. contact, 2 NO contacts)
R 1530 24V DC + 230V AC/DC 6 A GHR 153 0001 R0001 0.100 1
230V AC
R 1530 115V AC 230V AC/DC 6 A GHR 153 0002 R0001 0.100 1
R 1530 3-channel, electromechanical interface relay (1 ch. contact, 1 ch. contact, 2 NC contacts)
R 1530 115V AC 230V AC/DC 6 A GHR 153 0002 R0011 0.100 1
24 ABB STOTZ-KONTAKT GmbH
1SAC 1009 01 D0201
Relay stages Type R 1061/1041 are suitable
for "protective separation" in accordance with
VDE 0106, Part 101 up to 250 V, installation
category 2, pollution degree 3.
They are used preferably in the output stages of
electronic control systems.
Insulation group: VDE 0110 Gr. C 250 V AC
R1061/1S
SIGMA® terminal modules - compact design,
Type R 1041, R 1061
Technical data
Input data R 1061 (1 NO) Univ. current R 1041 (1 ch.) Univ. current
Rated control circuit voltage U c24 V AC/DC 230 V AC/DC 24 V AC/DC 230 V AC/DC 24 V AC/DC 230 V AC/DC
for "ON" 19.2 ... 30 V 90 ... 125 V 185 ... 255 V 19.2 ... 125 V 90 ... 125 V 185 ... 255 V
for "OFF" 0 ... 4 V 0 ... 10 V 0 ... 25 V 0 ... 4 V 0 ... 10 V 0 ... 25 V
Current consumption at Uc rated approx. 15 mA approx. 5 mA approx. 5 mA approx. 15 mA approx. 5 mA approx. 5 mA
Polarity reversal-protected (Input / Output) Yes Yes Yes Yes Yes Yes
Overvoltage suppression Yes Yes Yes Yes Yes Yes
Input impedance
Maximum switching frequency 10 Hz 10 Hz 10 Hz 10 Hz 10 Hz 10 Hz
Output data
Contact material AgSnO2AgSnO2AgSnO2AgSnO2AgSnO2AgSnO2
Rated operating voltage Ue250 V AC/AC 250 V AC/AC 250 V AC/AC 250 V AC/AC 250 V AC/AC 250 V AC/AC
Permissible voltage range for AC 12 V ... 380 V 12 V ... 380 V 12 V ... 380 V 12 V ... 380 V
for DC 12 V ... 300 V 12 V ... 300 V 12 V ... 300 V 12 V ... 300 V
Max. switching current AC 12 6 A 6 A 6 A 6 A 6 A 6 A
Operating current AC 15 at 220 V 3 A 3 A 3 A 3 A 3 A 3 A
DC 13 at 24 V 1 A 1 A 1 A 1 A 1 A 1 A
Rated switching capacity for AC 1500 VA 1500 VA 1500 VA 1500 VA 1500 VA 1500 VA
for DC 120 W 120 W 120 W 120 W 120 W 120 W
On delay tE10 ms 10 ms 10 ms 10 ms 10 ms 10 ms
Off delay tA15 ms 15 ms 15 ms 15 ms 15 ms 15 ms
Ambient temperature -20...+50 °C -20...+50 °C -20...+50 °C -20...+50 °C -20...+50 °C -20...+50 °C
Service life:
mechanical > 20 Mio > 20 Million > 20 Million > 20 Million > 20 Million > 20 Million
electrical at 220 V AC/3 A
24 V DC/4 A
Electrical isolation / Relay Yes Yes Yes Yes Yes Yes
Test voltage Input / output 4 kV 4 kV 4 kV 4 kV 4 kV 4 kV
Creepage distance Input / output > 8 mm > 8 mm > 8 mm > 8 mm
Accessories: Potential jumpers P-1010, P-1024
MBGE
Dimensions (in mm)
Width =6.5
Height= 85
Depth= 81
R1041/1W
ABB STOTZ-KONTAKT GmbH 25
1SAC 1009 01 D0201
SIGMA® terminal modules - compact design
Type series R 1048, R 1062, R 1064, R 1084
Technical data
MBGE
Dimensions (in mm)
Width = 6.5
Height = 85
Depth = 81
Input data R 1048 R 1062 R 1064 R 1084
Switching element FET TRIAC Transistor Transistor
Rated control circuit voltage Uc24 V DC 24 V DC 24 V DC 24 V DC
for "ON" 10 ... 45 V DC 10 ... 45 V DC 10 ... 45 V DC 10 ... 45 V DC
for "OFF" 0 ... 4 V DC 0 ... 4 V DC 0 ... 4 V DC 0 ... 4 V DC
Current consumption at Uc rated ca 5 mA ca 5 mA ca 5 mA ca 5 mA
Polarity reversal-protected (Input / Output) Yes Yes Yes Yes
Input impedance
Maximum switching frequency 10 Hz 20 Hz 10 Hz 50 Hz
Protective circuit Varistor Varistor Varistor Varistor
Output data
Rated operating voltage Ue max. 48 V DC 230 V AC 48 V DC 48 V DC
Permissible voltage range for AC - 12 ... 250 V AC - -
for DC 5 ... 50 V DC - 5 ... 50 V DC 5 ... 50 V DC
Switching current min. 1 mA 0.1 mA 1 mA 0.1 mA
Rated continuous current Iu (at 45°C) 2 A 0.5 A 1 A 0.1 A
On delay tE< 5 ms < 5 ms < 1 ms < 5 ms
Off delay tA10 ms 15 ms 5 ms 5 ms
Short-circuit-proof Yes No No No
Service life Virtually unlimited Virtually unlimited Virtually unlimited Virtually unlimited
Electrical isolation Yes Yes Yes Yes
Test voltage Input / output 2.5 kV 2.5 kV 2.5 kV 2.5 kV
Ambient temperature, operation -20 °C ... 60 °C -20 °C ... 60 °C -20 °C ... 60 °C -20 °C ... 60 °C
26 ABB STOTZ-KONTAKT GmbH
1SAC 1009 01 D0201
Input stages Type R1584 and R1585
Technical data
The input stages R 1584 and R 1585 are used
for electrically isolated connection of DC
(R1584) or AC (R1585) voltage signals to an
electronic controller.
Input data
Rated control circuit voltage U c
for „ON“
for „OFF“
Operating frequency
Current consumption bei UC Rated
Polarity reversal-protected
Input impedance
Maximum switching frequency
Output data
Switching element
Overvoltage protection
Rated operating voltage Ue
Permissible voltage range for DC
Rated continious current IU
Voltage drop in ON state
Leakage current in OFF state
in the case of Ue = 30 V DC
On delay tE
Off delay tA
Bounce time
Electrical isolation
Test voltage input / output
Creepage distance input / output
R1585
230 V AC/DC
180... 280 V AC/DC
0... 10 V AC/DC
47... 63 Hz
< 6.5 mA
yes
44 k
20 Hz
R1584
24 V DC
17... 32 V DC
0... 2 V DC
< 20 mA
up to 200 V
1 k
100 Hz
transistor
Suppressor diode
24 V DC
3... 30 V
100 mA
0.4 V
0.1 mA
5 ms < 20 ms
5 ms < 40 ms
Optocoupler
4 kV
8 mm
ABB 88 6277/4
ABB 88 6277/7
SST 221 95 M
Width: 11.25 mm
UcUe
A1 13
+
+
14
A2
UcUe
A1 13
+
14
A2
ABB STOTZ-KONTAKT GmbH 27
1SAC 1009 01 D0201
Input relay Type R1571
Technical data
R1571
ABB 88 6277/5
UcUe
6,3 AF
4 Agl
A1
14 (12)
13 (11)
A2
The input relays R1571 are used for electrical
isolation of electrical circuits. They contain an
electromechanical relay. The gold-plated relay
contacts allow switching of low voltages and
currents (analogue measurement values) and
increase the contact stability for signal inputs in
electronic controls.
Input data
Rated control circuit voltage Uc
for „ON“
for „OFF“
Current consumption at UC Rated
Polarity reversal-protected
Overvoltage suppression
Input impedance
Maximum switching frequency
Output data
Contact material
Rated operating voltage Ue
Permissible voltage range for AC
for DC
Max. switching current
Rated continious current IU
Rated switching capacity afor AC
for DC up to 30 V
for DC up to 250 V
On delay tE
Off delay tA
Bounce time
Service life:
mechanical
electrical at 220 V AC/3 A a
24 V DC/4 A a
Electrical isolation
Test voltage input/output
Creepage distance input/output
24 V AC/DC
20... 29 V DC
0... 2 V DC
< 20 mA
yes
yes
1.3 k
230 V AC/DC
176... 250 V AC/DC
0... 8 V AC/DC
< 5 mA
yes
yes
50 k
20 Hz
Ag AU 5µ
230 V AC
20 mV... 250 V
20 mV... 300 V
5 A (20 mA) b
3 A (5 mA) b
750 VA c
90 W
45 W
10 ms
10 ms
< 3ms
> 107
>7 x 105
> 106
Relay
4 kV
> 8 mm
a In the case of ohmic load
b The gold plating is preserved up to this current
c The gold plating is damaged above this switching capacity value
See Page 26
for dimension diagram
28 ABB STOTZ-KONTAKT GmbH
1SAC 1009 01 D0201
Output relay Type R1561, DC version
Technical data
ABB 88 6277/6
m 10 mA
UcUe
6,3 AF
4 Agl
A1
+
14 (12)
13 (11)
A2
230 V AC
12
Á
V... 250 V
12
Á
V... 300 V
10 A
6 A
3 A (3 A, B 300 V)
Â
0.1 A
1500 VA
90 W
45 W
10 ms
10 ms
< 3ms
> 107
> 7 x 105
> 106
Relay
4 kV
> 8 mm
24 V DC
17... 32 V DC
0... 2 V DC
< 20 mA
up to 200 V
Free-wheeling diode
800
20 Hz
Ag Cdo
The output relay R1561 electromagnetically
converts low voltage signals to floating output
commands.
A version with output contacts connected to an
RC network is available for damping inductive
breaking voltages.
Input data
Rated control circuit voltage Uc
for „ON“
for „OFF“
Current consumption bei UC Rated
Polarity reversal-protected
Overvoltage suppression
Input impedance
Maximum switching frequency
Output data
Contact material
Protective circuit comprising RC network
Residual current
Rated operating voltage Ue
Permissible voltage range for AC
for DC
Max. switching current
Rated continious current IU
Operating current AC 15 at 220 V
DC 13 at 24 V
Rated switching capacity a
for AC
for DC up to 30 V
for DC up to 250 V
On delay tE
Off delay tA
Bounce time
Service life:
mechanical
electrical at 220 V AC/3 A a
24 V DC/4 A a
Electrical isolation
Test voltage input / output
Creepage distance input / output
R1561
without protective circuit R1561
with protective circuit
a with resistive load
b Switching capacity > 0.2 W bei 12V
c
UL values
0.047 µF + 100
4 mA
See Page 26
for dimension diagram
R1561
Low power
230 V AC
12 b V... 250 V
12 b V... 300 V
10 A
6 A
3 A (3 A, B 300 V)c
0.1 A
1500 VA
90 W
45 W
10 ms
10 ms
< 3ms
> 107
> 7 x 105
> 106
Relay
4 kV
> 8 mm
ABB STOTZ-KONTAKT GmbH 29
1SAC 1009 01 D0201
Output relay Type R1561
(universal current version)
Technical data
yes
yes
ABB 88 6277/3
UcUe
6,3 AF
4 Agl
A1
14 (12)
13 (11)
A2
The universal current relay R1561 can be
controlled as required with DC or AC voltage.
The relays are available for the most common
control voltages.
Input data
Rated control circuit voltage Uc
for „ON“
for „OFF“
Current consumption at UC Rated
Polarity reversal-protected
Overvoltagesuppression
Input impedance
Maximum switching frequency
Output data
Contact material
Rated operating voltage Ue
Permissible voltage range for AC
for DC
Max. switching current
Rated continious current I U
Operating current AC 15 at 220 V
DC 13 at 24 V
Rated switching capacity a for AC
for DC up to 30 V
for DC up to 250 V
On delay tE
Off delay tA
Bounce time
Service life:
mechanical
electrical at 220 V AC/3 A a
24 V DC/4 A a
Electrical isolation
Test voltage input / output
Creepage distance input / output
R1561
24 V AC/DC
20... 29 V AC/DC
0... 2 V
< 20 mA
800
60 V AC/DC
40... 72 V AC/DC
0... 2 V
< 10 mA
7.5 k
110 V AC/DC
88... 130 V AC/DC
0... 4 V
< 5 mA
25 k
230 V AC/DC
176... 250 V AC/DC
0... 8 V
< 5 mA
50k
20 Hz
Ag Cdo
230 V AC
12 V... 250 V b
12 V... 300 V b
10 A
6 A
3 A
0.1 A
1500 VA
90 W
45 W
10 ms
10 ms
< 3 ms
> 107
> 7 x 105
> 106
Relay
4 kV
> 8 mm
a For ohmic load
b Switching capacity > 0.2 W See Page 26
for dimension diagram
30 ABB STOTZ-KONTAKT GmbH
1SAC 1009 01 D0201
Output relay Type R1551
Technical data
ABB 88 7066/1
ABB 88 7066/2
Ag Cdo
230 V AC
12 b V... 250 V
12 b V... 300 V
5 A
4 A
2 A
1 A
660 VA
60 W
45 W
R1551 (1 W)
a For ohmic load
b Switching capacity > 0.2 W See Page 26
for dimension diagram
R1551 (2 NO; 2 NC)
< 35 mA < 20 mA
up to 200 V
Free-wheeling diode
800 1.3
20 Hz
12
Á
V... 250 V
12
Á
V... 300 V
10 A
6 A
3 A
1 A
1500 VA
90 W
45 W
10 ms
10 ms
5 ms
> 107
> 5 x 105
> 106
> 107
> 7 x 105
> 106
Relay
4 kV
> 8 mm
24 V DC
17... 32 V DC
0... 2 V
The relay stages, Type R1551, are used
preferably in the output levels of electronic
controllers.
Input data
Rated control circuit voltage Uc
for „ON“
for „OFF“
Current consumption at UC Rated
Polarity reversal-protected
Overvoltagesuppression
Input impedance
Maximum switching frequency
Output data
Contact material
Rated operating voltage Ue
Permissible voltage range for AC
for DC
Max. switching current
Rated continious current IU
Operating current AC 15 at 220 V
DC 13 at 24 V
Rated switching capacityafor AC
for DC up to 30 V
for DC up to 250 V
On delay tE
Off delay tA
Bounce time
Service life:
mechanical
electrical at 220 V AC/3 Aa
24 V DC/4 Aa
Electrical isolation
Test voltage input / output
Creepage distance input / output
ABB STOTZ-KONTAKT GmbH 31
1SAC 1009 01 D0201
Output stage Type R1552
Technical data
ABB 88 6277/8
a Units installed with lateral clearance
SST 221 95 M
Width:
11.25 mm
UcUe
2 AF
A1
14
13
A2
230 V AC
155... 240 V AC
0... 33 V AC
< 10 mA
< 100 mA
100 m
Triac
Varistor
400 V AC
47... 63 Hz
24... 420 V
0.8 A/1A
220 V AC / 0.6 A
50 A
2.4 V
50 µA
50 mA
13 A2 s
< 30 ms (f = 50 Hz)
< 90 ms (f = 50 Hz)
2 kVrms
> 109
The hybrid relay, Type R1552, has a triac as the
switching element. Control and electrical
isolation are performed by a Reed relay. This
version allows inductive loads to be switched.
There is no need for a protective circuit since
the output semiconductor is protected by a
varistor.
Input data
Rated control circuit voltage Uc
for „ON“
for „OFF“
Current consumption at UC rated
Switch-on peak max.
Line length max.
Output data
Switching element
Overvoltage protection
Rated operating voltage Ue
Operating frequency
Permissible voltage range for AC
Rated continious current IU
(Tu = 55 °C/45 °C)
a
Rated switching capacity a for AC 15/AC 3
Max. overcurrent (10 ms)
Voltage drop
Leakage current in Off state at Ue Rated
Minimum load current
Limit load integral
i2 dt (t = 10 ms)
On delay tE
Off delay tA
Test voltage input / output
Service life mechanical
R1552
32 ABB STOTZ-KONTAKT GmbH
1SAC 1009 01 D0201
The relay stages, Type R 1541/1542, are
suitable for "safety separation", as defined by
VDE 0106, Part 101 up to 250 V, installation
category 2, pollution severity 3.
They are used preferably in the output levels of
electronic controllers.
SST 093 92 S
Output relay Type R 1541 / 1542
Technical data
SST 221 95 M
Width:
11.25 mm
UcUe
6,3 AF
4 AT
A1
11
12
14
A2
UcUe
6,3 AF
4 AT
A1 11 21 22
12 24
14
A2
SST 093 96 S
Input data R 1541 (1 W) universal current R 1542 (2 W) universal current
Rated control circuit voltage U c24 V DC/AC 230 V DC/AC 24 V DC/AC 230 V DC/AC
for „ON“ 17 ... 32 V 176 ... 250 V 17 ... 32 V 176 ... 250 V
for „OFF“ 0 ... 2 V 0 ... 8 V 0 ... 2 V 0 ... 8 V
Current consumption at Uc Rated < 30 mA < 5 mA < 20 mA < 5 mA
Polarity reversal-protected (input / output) yes yes yes yes
Overvoltage suppression yes yes yes yes
Input impedance 800 50 k24 50 k
Maximum switching frequency 20 Hz 20 Hz 20 Hz 20 Hz
Output data
Contact material AgCdO AgCdO Ag/Au Ag/Au
Rated operating voltage Ue230 V AC 230 V AC 230 V AC 230 V AC
Permissible voltage range for AC 12 V ... 380 V b12 V ... 380 Vb12 V ... 380 V b12 V ... 380 Vb
for DC 12 V ... 300 V b12 V ... 300 V 12 V ... 300 V b12 V ... 300 Vb
Max. switching current 12 A 12 A 5 A 5 A
Rated continious current Iu6 A6 A2 A2 A
Operating current AC 15 at 220 V 4 A 4 A 2 A 2 A
DC 13 at 24 V 1 A 1 A 0.5 A 0.5 A
Rated switching capacity afor AC 1500 VA 1500 VA 250 VA 250 VA
for DC to 30 V 90 W 90 W 15 W 15 W
for DC to 250 V 45 W 45 W 7 W 7 W
On delay tE10 ms 10 ms 5 ms 5 ms
Off delay tA10 ms 10 ms 3 ms 3 ms
Bounce time 5 ms 5 ms 3 ms 3 ms
Service life
mechanical > 107> 107> 107> 107
electrical at 220 V AC/3 A a> 7x10 5> 7x105
24 V DC/4 A
a> 106> 106
Electrical isolation / Relay yes yes yes yes
Test voltage input / output 4 kV 4 kV 1.5 kV 1.5 kV
Creepage distance input / output > 8 mm > 8 mm > 8 mm > 8 mm
a
For ohmic load
b
Switching capacity > 0.2 W
ABB STOTZ-KONTAKT GmbH 33
1SAC 1009 01 D0201
Output relay Type Series R 1600
Technical data
SST 095 92 SSST 094 92 S
SST 096 92 S
SST 221 95 M
Width;
11.25 mm
UcUe
A1
+
14
13
A2
+
+
UcUe
A1
14
13
A2
+
+
UcUe
A1 +
14
13
A2
Input data
Rated control circuit voltage Uc
for „ON“
for „OFF“
Current consumption at Uc Rated
Polarity reversal-protected (input / output)
Input impedance
Maximum switching frequency
Output data
Contact material
Rated operating voltage Ue
Permissible voltage range for AC
for DC
Min. switching current
Rated continious current Iu (at 45°C)
On delay tE
Off delay tA
Short-circuit-proof
Service life
Electrical isolation / relay
Test voltage input / output
a for output current max. (3 A DC)
R 1647 R 1648 R 1662 R 1664
24 V DC 24 V DC 24 V DC 24 V DC
17 ... 32 V DC 17 ... 32 V DC 17 ... 32 V DC 17 ... 32 V DC
0 ... 2 V DC 0 ... 2 V DC 0 ... 2 V DC 0 ... 2 V DC
30 mA 30 mA 8 mA 8 mA
yes yes yes yes
1.7 k1.7 k3.0 k3.0 k
50 / s 50 / s > 1 / s > 3 / s a
-
60 V DC
-
5 - 72 V
10 mA
3 A
< 4 ms
< 8 ms
yes
virtually unlimited
yes
4 kV
-
230 V AC
10 - 264 V
-
10 mA
3 A
10 ms
10 ms
nein
virtually unlimited
yes
4 kV
-
24 V DC
-
5 - 33 V
10 mA
4 A
< 4 ms
< 8 ms
yes
virtually unlimited
yes
4 kV
-
60 V DC
-
12 - 72 V
10 mA
3 A
< 10 ms
< 10 ms
nein
virtually unlimited
yes
4 kV
34 ABB STOTZ-KONTAKT GmbH
1SAC 1009 01 D0201
3-channel interface relay Type R 1530
Technical data
3-channel interface relay for decoupling
output signals and check-back signals
between control system, PLC and process.
23 24 33 34
A12 42 44 41
O Fault
O Relay 1
O Relay 2
A11 A21 A41 A42
11 14 12
Uc1
Uc2
Uc3
Ue1
Ue2
Ue3
A11
A41
A12
A21
A42
+
-
~
+
14
34
44
12
24
23
42
11
33
41
SST 202 97
Input data Relay 1, 2 Relay 3
Rated control circuit voltage U c24 V DC 230 V AC / DC
Current consumption at Uc20 mA, 30 mA 20 mA
Polarity reversal-protected yes yes
Operate/release time 6 / 2 ms, 8 / 12 ms 6 / 2 ms
Switching frequency DC 1 / s 1 / s
safety separation,
no stationary arc
Switching frequency 20 / s, 10 / s 20 / s
Output data
Output Ue1 1 changeover contact
Output Ue2 2 NO contacts
Output Ue3 1 changeover contact
Rated operating voltage Ue250 V AC / DC
Max. switching current AC 6 A
Max. switching current DC 0.4 A
Rated breaking/making capacity AC 1500 VA
Rated breaking/making capacity DC up to 30 V 240 W
General data
Electrical isolation Relay
Test voltage I/O > 4 kV
Relay creepage distance I/O > 8 mm
Mechanical service life 30 x 10 6
Electrical service life Load-dependent
Function/fault indicator LED yellow / LED red
Ambient temperature - 40 ... + 60 °C
Dimensions (W x H x D) 27 x 90 x 96 mm
ABB STOTZ-KONTAKT GmbH 35
1SAC 1009 01 D0201
Notes
ABB STOTZ-KONTAKT GmbH
P.O.BOX 101680
D-69006 Heidelberg
Telephone ++49 62 21 / 7 01-00
Telefax ++49 62 21 / 7 01-1115
Internet http://www.abb.de/sst
Publication
no: 1SAC 1009 01 D0201
Printed in Germany (02/01)