Part Number Voltage Frequency Nb
Phases
Airow Pressure
No-
minal
speed
Noise
level LP
Nominal
current
Starng
current power Capacitor
V Hz l/s CFM mm H² o inch H² o RPM dBA mA mA W µF
148VE02 81 001 220 50 1 49 103,88 4,5 0,177 1400 36,0 60 80 13 0,32
81 220 60 1 58 122,96 6,0 0,236 1650 39,0 60 80 14 0,32
82 115 50 1 49 103,88 4,5 0,177 1400 36,0 100 140 11 1,0
82 115 60 1 58 122,96 6,0 0,236 1650 39,0 90 140 11 1,0
148VK02 81 001 220 50 1 100 212,00 18,0 0,708 2800 53,0 200 390 35 2,2
81 220 60 1 117 248,04 21,0 0,826 3200 57,0 170 370 33 2,2
82 115 50 1 100 212,00 18,7 0,736 2850 54,0 300 610 32 2,7
82 115 60 1 119 252,28 24,0 0,945 3300 57,0 270 590 32 2,7
148VP02 81 001 220 50 1 82 173,84 8,3 0,327 2400 49,0 70 100 16 0,69
81 220 60 1 70 148,40 5,4 0,213 2000 44,0 100 105 22 0,69
82 115 50 1 81 171,72 7,3 0,287 2350 50,0 120 170 14 2,2
82 115 60 1 70 148,40 5,6 0,220 2100 45,5 160 180 18 2,2
CHARACTERISTICS
Weight: 0,9 Kg / 1,99 Lb
Housing in Aluminium
Impeller in plasc UL 94 V-0
L-10 life expectancy at 40°C: 80.000 hours
Operang temperature range: -10 / +70 °C
Storage temperature: -54 / +85°C
Connecon: Terminals
VE/VP impedance protected;VK thermally
protected
IP20
OPTIONS
Speed sensor
Other IP levels
Flying leads connecon
Salt spray protecon
Shocks and vibraons protecon
Marine applicaon
Wide temperature range
Other voltages
Three phases
0 100 200 300 400 500
0,0
0,1
0,2
0,3
0,4
0,5
0,6
0,7
0,8
0,9
0
5
10
15
20
25
0 20 40 60 80 100 120
AIRFLOW IN CFM
AIRFLOW IN l/s
STATIC PRESSURE IN mmH2O
STATIC PRESSURE IN inchH2O
AC AXIAL FAN 148V 172 x 150 x 38 mm
6,77 x 5,9 x 1,5 ''
Non contractual document.
All specicaons are subject to change without prior noce.
Picture for informaon only.
For professional use only. Please refer to the condions of use of our catalogue.
Updated on 03/12/18