147
BHC and Evox Rifa Electrolytic Capacitors
---MS12AAMA1STD 25 325 -0% +25% 38x75 1.67%
---MS12AAMK1STD 25 360 ±10% 38x75 1.67%
---MS12ABMA1STD 85 460 -0% +25% 38x90 1.67%
---MS12ABMK1STD 90 510 ±10% 38x90 1.67%
---MS12ACMA1STD 120 670 -0% +25% 38x116 1.67%
---MS12ACMK1STD 130 750 ±10% 38x116 1.67%
---MD12AAMA1STD 25 325 -0% +25% 38x75 1.67% 0.55%
---MD12AAMK1STD 25 360 ±10% 38x75 1.67% 0.55%
---MD12ABMA1STD 85 460 -0% +25% 38x90 1.67% 0.55%
---MD12ABMK1STD 90 510 ±10% 38x90 1.67% 0.55%
---MD12ACMA1STD 120 670 -0% +25% 38x116 1.67% 0.55%
---MD12ACMK1STD 130 750 ±10% 38x116 1.67% 0.55%
---MS22AAMA1STD 30 65 -0% +25% 38x75 1.67%
---MS22AAMK1STD 30 70 ±10% 38x75 1.67%
---MS22ABMA1STD 40 90 -0% +25% 38x90 1.67%
---MS22ABMK1STD 40 100 ±10% 38x90 1.67%
---MS22ACMA1STD 55 130 -0% +25% 38x116 1.67%
---MS22ACMK1STD 65 150 ±10% 38x116 1.67%
---MD22AAMA1STD 30 65 -0% +25% 38x75 1.67% 0.55%
---MD22AAMK1STD 30 70 ±10% 38x75 1.67% 0.55%
---MD22ABMA1STD 40 90 -0% +25% 38x90 1.67% 0.55%
---MD22ABMK1STD 40 100 ±10% 38x90 1.67% 0.55%
---MD22ACMA1STD 55 130 -0% +25% 38x116 1.67% 0.55%
---MD22ACMK1STD 65 130 ±10% 38x116 1.67% 0.55%
---MS26AAMA1STD 25 55 -0% +25% 38x75 1.67%
---MS26AAMK1STD 25 60 ±10% 38x75 1.67%
---MS26ABMA1STD 35 75 -0% +25% 38x90 1.67%
---MS26ABMK1STD 35 85 ±10% 38x90 1.67%
---MS26ACMA1STD 50 110 -0% +25% 38x116 1.67%
---MS26ACMK1STD 55 125 ±10% 38x116 1.67%
---MD26AAMA1STD 25 50 -0% +25% 38x75 1.67% 0.55%
---MD26AAMK1STD 25 55 ±10% 38x75 1.67% 0.55%
---MD26ABMA1STD 30 70 -0% +25% 38x90 1.67% 0.55%
---MD26ABMK1STD 35 80 ±10% 38x90 1.67% 0.55%
---MD26ACMA1STD 45 100 -0% +25% 38x116 1.67% 0.55%
---MD26ACMK1STD 50 115 ±10% 38x116 1.67% 0.55%
MS / MD Motor Starting Capacitors
Type number Min. Cap. Max. Cap. Tolerance Can Size Duty Cycle
(µF) (µF) (mm) @ 120V rms @ 150V rms
Type number Min. Cap. Max. Cap. Tolerance Can Size Duty Cycle
(µF) (µF) (mm) @ 220V rms @ 280V rms
Type number Min. Cap. Max. Cap. Tolerance Can Size Duty Cycle
(µF) (µF) (mm) @ 260V rms @ 330V rms
120Vac
220Vac
260Vac
Capacitance code
e.g. 030=30µF, 120=120µF
*
TECHNICAL DATA
Dual Voltage Rating
The MD range of capacitors is designed
with a dual voltage rating. The lower voltage
rating relates to a duty cycle of 1.67% and
the upper voltage rating relates to a duty
cycle of 0.55%.
Power Factor
The tangent of the loss angle for motor start
capacitors shall not exceed 0.1 and shall be
calculated as follows:
Tan δ = W = true watts
V x I apparent watts
Duty Cycle
The standard rating is 1.67% or 1/60th full
time and corresponds to a maximum duty
of 20 starts, each of three seconds duration
per hour. It is expressed as 3/1.67 (a 3 minute
cycle with 1.67% duration during which the
capacitor may be energised). If the same
capacitor is to be used for a duty cycle of
60 starts per hour the cycle duration will
be 1 minute. The operation time per cycle
will then have to be reduced to 1.67% of 1
minute (i.e. 1 second). Alternative duty cycles
are available on request.
Presence of Run Capacitor
When the motor is fitted with both starting
and run capacitors, consideration should be
given to fitting of the appropriate discharge
resistor to the starting capacitor. This is
to protect the run capacitor from damage
through discharge of the starting capacitor.
Container Form
Cylindrical mouldings, meeting creepage
and clearance distances, according to IEC
60335-1 and flammability ratings according
to UL94-V1.