Other Wiring Products Index Product Adapter, Nylon Plug In Lockout Devices Fluorescent Starters Fluorescent Lampholders Receptacle Circuit Tester Cord Grip Lockout Specifications Page Number U-2 U-3 U-4 U-4 U-5 U-5 U-6 Other Wiring Products Section U Index Dimensions in Inches (mm) www.hubbell-wiring.com Other Wiring Products Other Wiring Products Adapters HBL2274 Slot End Female HBL5273L Blade End Male Nylon Convenience Adapters G HBL5289 NEMA Configuration Female Slot End G W G W 9053A W G Male Blade End Rating NEMA No. NEMA 5-15P 15A 125V UL CSA W W W G G W NEMA L5-15P 15A 125V UL/CSA NEMA L5-20P 20A 125V UL/CSA G NEMA L5-30P 30A 125V UL/CSA Catalog Numbers 20A 125V 5-20R HBL2270 HBL2274 HBL2129 HBL31CM29* 15A 125V L5-15R HBL2271 - - - 20A 125V L5-20R HBL2128 - - - Caution: Where adapters have different ratings on the blade and slot end the following precautions must be exercised in their use. 9054A (1) Remember that overcurrent protection is determined by the blade end. (2) The use of the adapter should be limited to the lowest rated end of the adapter in order to prevent overheating. (3) Adapters are not GFCI protected. Plug In Adapters Catalog Numbers HBL5273L HBL5289* 9053A* 9054A* Adapters Description Male end - 2 wire parallel polarized blades, 15A, 125V. Female end - 3 wire 15A, 125V straight slot grounding. Male end - 3 wire crow foot 15A, 125V blades. Female end - 3 wire 15A, 125V straight slot grounding. Male end - 3 wire 10A, 250V, 15A, 125V Twist-Lock(R) blades. Female end - 3 wire 15A, 125V straight slot grounding. Male end - 3 wire 15A, 125V straight blade grounding. Female end - 10A, 250V, 15A 125V Twist-Lock slots. Must always be used with a grounded receptacle. *Not UL Listed. U-2 www.hubbell-wiring.com Dimensions in Inches (mm) Lockout Devices For Electrical Safety PLUGOUT(R), Keyed PLUGOUT(R), and SWITCHOUT(R) safety devices provide an approved method of complying with OSHA Lockout/Tagout regulation 29CFR 1910.147. PLUGOUT, Keyed PLUGOUT and SWITCHOUT Lockout Devices Description Small yellow lockout device. Medium yellow lockout device. Large yellow lockout device. Yellow SWITCHOUT device. Yellow lockout kit. Yellow keyed PLUGOUT, keyed differently. Yellow keyed PLUGOUT, keyed alike. 3.14" (79.8) Typical Devices Catalog Accommodated Numbers 15 and 20A molded on plugs. HLDMP 20 and 30A Twist-Lock(R) plugs. HLD 20, 30 and 60A metallic and HLD2 non-metallic Pin & Sleeve, Hubbellock(R) & 50A Twist-Lock plugs. Toggle switch. HSLDPK2* One each of above lockout devices. HLDKIT 15 and 20A, 125V straight blade HKLD plugs with holes in blades. 15 and 20A, 125V straight blade HKLDPK2* plugs with holes in blades. Other Wiring Products Other Wiring Products 4.22" (107.2) HLDMP 4.27" (108.5) 7.27" (184.7) Notes: See page U-6 for specifications. *Two devices per package. HLD 6.31" (160.3) 12.5" (317.5) HLD2 HSLDPK2 Lockout Devices HKLDPK2 Dimensions in Inches (mm) www.hubbell-wiring.com U-3 Other Wiring Products Other Wiring Products Fluorescent Starters Fluorescent Lampholders Fluorescent Starters Description Neostart The Hubbell Neostart is a glow discharge type of starter which combines fast starting speed with rugged, dependable operation. The Neostart lights the lamp very rapidly and insures satisfactory lamp operation throughout rated life. Because of its rugged construction, it can be depended upon to withstand continued punishment resulting from lamp failure. In addition, it operates satisfactory over a wide temperature range. In dual lamp circuits, the Neostart lights both lamps quickly and uniformly. FS40400 Manual Reset Catalog Numbers Lamps 14, 15 and 20 watt lamps FS2 13, 30 and 40 watt lamps FS4 4, 6 and 8 watt lamps FS5 22 watt circline, 25 watt standard lamps FS25 Manual Reset Hubbell Manual Reset starters provide positive 14, 15 and 20 watt lamps FS20 protection for the fluorescent installation by deactivating a lamp when it burns out. This 40 watt lamps FS40400 eliminates annoying flashing and protects the ballast and the starter from damage. When a 90 and 100 watt lamps FS850 lamp fails, the cut-out mechanism in the (four contacts) Hubbell Manual Reset starter breaks the circuit and de-activates the lamp instantly. Yet, once the burned out lamp is replaced, the new lamp can be re-activated by simply pressing a button on the top of the starter can. This closes the circuit, and the starting cycle is initiated. Allows proper preheating of premium type 3 lamps or standard lamps in lead circuits of 2 or 3 lamp fixtures. Fluorescent Lampholders Fluorescent Starters & Lampholders Description White, push-in terminals. White, slimline fixture type. White, slimline fixture type. HBL2937 U-4 HBL2988 High Voltage End www.hubbell-wiring.com Rating 660 watts, 600V. 660 watts, 1000V. 660 watts, 250V. Catalog Numbers HBL2937 HBL2988 HBL2989 HLB2989 Low Voltage End Dimensions in Inches (mm) Other Wiring Products Other Wiring Products Receptacle Circuit Tester Cord Grip Receptacle Circuit Tester Description Receptacle circuit tester. Catalog Numbers HBL5200 How It Operates The Hubbell HBL5200 Receptacle Circuit Tester has a simple arrangement of neon lights which visually indicate and identify various fault conditions in electrical circuits (see chart below). Operation is quick and easy. By plugging the HBL5200 Tester into a single phase, 125V, 2-pole, 3-wire outlet the combination of lighted and/or unlighted lamps will immediately indicate circuit condition. HBL5200 Features UL Listed. Large, easy to read symbols. Recessed indicating lamps with one piece Polycarbonate lens. Tough impact resistant nylon housing. Use information and instructions printed on durable Polyester labels permanently attached to the tester. Rotatable labels can be easily read regardless of tester position. Correct Wiring Open Reversed Ground Polarity Wire Open Neutral Wire Open Hot Wire Hot on Neut. Hot & Term. & Hot Ground Term. Reversed Unwired Neutral Ground Hot Indicates Unlighted Lamp Indicates Lighted Lamp Note: When testing other receptacle types, use HBL5200 only with polarized adapters. Do not use on circuits supplying cardiac catheterized patients - may be a shock hazard. Description Cord grip for 1/2" knockouts. *Not UL Listed. Circuit Tester & Cord Grip Cord Grip Catalog Numbers HBL112* HBL112 Dimensions in Inches (mm) www.hubbell-wiring.com U-5 Other Wiring Products Other Wiring Products Lockout Devices For Electrical Safety Specifications Typical Specification Description Housing Optional storage position Color Instructional Information Ambient Operating Temperature PLUGOUT(R) Devices Yellow lockout device. UV stabilized polypropylene, heavy metal free colorant. Stores on cable when not in use. High visibility yellow. Permanently molded into housing. Maximum continuous 140F (60C), minimum continuous -20F( -29C). Plug Sizes & Padlocks Accommodated Plug Diameter Catalog Numbers HLDMP 0.79" (20.0) min., 1.73" (44.0) max. 3.70" (94.0) max. 0.64" (16.3) max. 2 locks, 5/16" (7.9) shackle dia. Plug Length Cord Max. No. of Padlocks Typical Specification Description Housing Optional storage position Color Instructional Information Ambient Operating Temperature HLD 1.50" (38.1) min., 2.75" (69.8) max. 4.75" (120.6) max. 1.11" (28.2) max. HLD2 1.90" (48.3) min., 4.50" (114.3) max. 10.15" (257.8) max. 1.45" (36.8) max. 4 locks, 3/8" (9.5) shackle dia. 4 locks, 3/8" (9.5) shackle dia. Keyed PLUGOUT(R) Device Catalog Numbers HKLD & HKLDPK2 ABS w/ metal cylindrical lock. UV stabilized polypropylene, heavy metal free colorant. Stores on cable when not in use. High visibility yellow. Permanently molded into housing. Indoor use only. Specifications SWITCHOUT(R) Device Catalog Numbers HSLDPK2 Yellow switchout device. Nylon, heavy metal free colorant. High visibility yellow. Installs without removal of existing wallplate screws. Two locks, 5/16" (7.9) shackle dia. Maximum continuous 140F (60C), Minimum continuous -20F( -29C). Lockout Devices Typical Specification Description Housing Color Installation Max. No. of Padlocks Ambient Operating Temperature U-6 www.hubbell-wiring.com Dimensions in Inches (mm)