015AZ2.0~015AZ12
2004-05-06
1
TOSHIBA Diode Silicon Epitaxial Planar Type
015AZ2.0~015AZ12
Constant Voltage Regulation Applications
Small package
Nominal voltage tolerance about ±2.5%
(2.0V~12V)
Maximum Ratings (Ta = 25°C)
Characteristics Symbol Rating Unit
Power dissipation P* 150 mW
Junction temperature Tj 125 °C
Storage temperature range Tstg 55~125 °C
* Mounted on a glass epoxy circuit board of 20 × 20mm,
Pad dimension of 4 × 4mm.
Electrical Characteristics
(See Page 2~3)
Marking
Example1:015AZ2.4-X Example2:015AZ2.4-Z Example3:015AZ12-X
Pin Assignment (top view)
Unit: mm
JEDEC
JEITA
TOSHIBA 1-1G1A
Weight: 1.4 mg (typ.)
24
D
ec
i
ma
l
po
i
nt
V
o
lt
age ran
k
: VZ=
(
VZ rankin
g
volta
g
e
)
X 0.1, nil : VZ=VZ rankin
g
volta
g
e
24 24 12
VZ additional ranking
upper --- X rank , middle --- Y rank , lower --- Z rank
015AZ2.0~015AZ12
2004-05-06
2
Electrical Characteristics (Ta = 25°C)
Zener
Voltage
Dynamic
Impedance
Knee Dynamic
Impedance
Reverse
Current
* VZ (V) ZZ() ZZK()IR (µA)
Type No.
Min Max
IZ
(mA)
Max
IZ
(mA)
Max
IZ
(mA)
Max
VR
(V)
X 1.85 2.05
015AZ2.0 **
Z 1.95 2.15
5 100 5 1000 0.5 120 0.5
X 2.05 2.26
015AZ2.2 **
Z 2.16 2.38
5 100 5 1000 0.5 120 1.0
X 2.28 2.50
015AZ2.4
Z 2.40 2.60
5 100 5 1000 0.5 120 1.0
X 2.50 2.75
015AZ2.7
Z 2.65 2.90
5 110 5 1000 0.5 120 1.0
X 2.80 3.05
015AZ3.0
Z 2.95 3.20
5 120 5 1000 0.5 50 1.0
X 3.10 3.35
015AZ3.3
Z 3.25 3.50
5 130 5 1000 0.5 20 1.0
X 3.40 3.65
015AZ3.6
Z 3.55 3.80
5 130 5 1000 0.5 10 1.0
X 3.70 3.97
015AZ3.9
Z 3.87 4.10
5 130 5 1000 0.5 10 1.0
X 4.00 4.23
Y 4.13 4.35
015AZ4.3
Z 4.25 4.50
5 130 5 1000 0.5 5 1.0
X 4.40 4.63
Y 4.53 4.76
015AZ4.7
Z 4.66 4.90
5 120 5 1000 0.5 5 1.0
X 4.80 5.07
Y 4.97 5.24
015AZ5.1
Z 5.14 5.40
5 70 5 1000 0.5 1 1.5
X 5.30 5.63
Y 5.43 5.81
015AZ5.6
Z 5.61 6.00
5 40 5 900 0.5 1 2.5
X 5.80 6.20
Y 6.00 6.39
015AZ6.2
Z 6.19 6.60
5 30 5 500 0.5 1 3.0
X 6.40 6.80
Y 6.60 7.02
015AZ6.8
Z 6.82 7.20
5 25 5 150 0.5 0.5 5.0
* : Test time: t = 30ms
** : Product by order.
015AZ2.0~015AZ12
2004-05-06
3
Electrical Characteristics (Ta = 25ºC)
Zener
Voltage
Dynamic
Impedance
Knee Dynamic
Impedance
Reverse
Current
* VZ (V) ZZ() ZZK ()I
R (µA)
Type No.
Min Max
IZ
(mA)
Max
IZ
(mA)
Max
IZ
(mA)
Max
VR
(V)
X 7.00 7.43
Y 7.23 7.66
015AZ7.5
Z 7.46 7.90
5 23 5 120 0.5 0.5 6.0
X 7.70 8.16
Y 7.96 8.43
015AZ8.2
Z 8.23 8.70
5 20 5 120 0.5 0.5 6.5
X 8.50 9.00
Y 8.80 9.30
015AZ9.1
Z 9.10 9.60
5 18 5 120 0.5 0.5 7.0
X 9.40 9.93
Y 9.73 10.26
015AZ10
Z 10.06 10.60
5 15 5 120 0.5 0.5 8.0
X 10.40 10.98
Y 10.73 11.26
015AZ11
Z 11.06 11.60
5 15 5 120 0.5 0.5 8.5
X 11.40 11.93
Y 11.73 12.26
015AZ12
Z 12.06 12.60
5 15 5 110 0.5 0.5 9.0
* : Test time: t = 30ms
015AZ2.0~015AZ12
2004-05-06
4
ZENNER VOLTAGE VZ (V)
ZENNER CURRENT IZ (A)
015AZ2.0~015AZ12
2004-05-06
5
015AZ2.0~015AZ12
2004-05-06
6
The information contained herein is subject to change without notice.
The information contained herein is presented only as a guide for the applications of our products. No
responsibility is assumed by TOSHIBA for any infringements of patents or other rights of the third parties which
may result from its use. No license is granted by implication or otherwise under any patent or patent rights of
TOSHIBA or others.
TOSHIBA is continually working to improve the quality and reliability of its products. Nevertheless, semiconductor
devices in general can malfunction or fail due to their inherent electrical sensitivity and vulnerability to physical
stress. It is the responsibility of the buyer, when utilizing TOSHIBA products, to comply with the standards of
safety in making a safe design for the entire system, and to avoid situations in which a malfunction or failure of
such TOSHIBA products could cause loss of human life, bodily injury or damage to property.
In developing your designs, please ensure that TOSHIBA products are used within specified operating ranges as
set forth in the most recent TOSHIBA products specifications. Also, please keep in mind the precautions and
conditions set forth in the “Handling Guide for Semiconductor Devices,” or “TOSHIBA Semiconductor Reliability
Handbook” etc..
The TOSHIBA products listed in this document are intended for usage in general electronics applications
(computer, personal equipment, office equipment, measuring equipment, industrial robotics, domestic appliances,
etc.). These TOSHIBA products are neither intended nor warranted for usage in equipment that requires
extraordinarily high quality and/or reliability or a malfunction or failure of which may cause loss of human life or
bodily injury (“Unintended Usage”). Unintended Usage include atomic energy control instruments, airplane or
spaceship instruments, transportation instruments, traffic signal instruments, combustion control instruments,
medical instruments, all types of safety devices, etc.. Unintended Usage of TOSHIBA products listed in this
document shall be made at the customer’s own risk.
TOSHIBA products should not be embedded to the downstream products which are prohibited to be produced
and sold, under any law and regulations.
030619EAA
RESTRICTIONS ON PRODUCT USE