80 Series - Modular timers 16 A Features 80.01 80.11 Multi-function and mono-function timer range 80.01 - Multi-function & multi-voltage 80.11 - ON delay, multi-voltage 17.5 mm wide Six time scales from 0.1s to 24h * High input/output isolation * 35 mm rail (EN 60715) mount * "Blade + cross" - both flat blade and cross head screw drivers can be used to adjust the range and function selectors, the timing trimmer, and to disengage the rail mounting clip * New multi-voltage versions with "PWM clever" technology * * 80.01 / 80.11 Screw terminal 80.01 * * Multi-voltage Multi-function * * AI: ON delay DI: ON pulse SW: Symmetrical recycling: ON start BE: Signal OFF delay CE: Signal ON and OFF delay DE: Signal ON pulse Multi-voltage Mono-function AI: ON delay 80.11 FOR UL HORSEPOWER AND PILOT DUTY RATINGS SEE "General technical information" page V Wiring diagram (with signal START) Wiring diagram (without signal START) Wiring diagram (without signal START) Contact specification Contact configuration Rated current/Maximum peak current A Rated voltage/Maximum switching voltage V AC Rated load AC1 VA Rated load AC15 (230 V AC) Single phase motor rating (230 V AC) Breaking capacity DC1: 30/110/220 V Minimum switching load 1 CO (SPDT) 1 CO (SPDT) 16/30 16/30 250/400 250/400 4,000 4,000 VA 750 750 kW 0.55 0.55 16/0.3/0.12 16/0.3/0.12 500 (10/5) 500 (10/5) AgCdO AgCdO 12...240 24...240 A mW (V/mA) Standard contact material Supply specification Nominal voltage (UN) V AC (50/60 Hz) Rated power AC/DC VA (50 Hz)/W 12...240 24...240 < 1.8 / < 1 < 1.8 / < 1 AC (10.8...265)V (17...265)V DC (10.8...265)V (17...265)V V DC Operating range Technical data Specified time range (0.1...2)s, (1...20)s, (0.1...2)min, (1...20)min, (0.1...2)h, (1...24)h Repeatability % 1 1 Recovery time ms 50 50 Minimum control impulse ms 50 -- % 5 5 100*103 100*103 -10...+50 -10...+50 IP 20 IP 20 Setting accuracy-full range Electrical life at rated load in AC1 Ambient temperature range Protection category cycles C Approvals (according to type) 1 80 Series - Modular timers 16 A Features 80.21 80.41 80.91 Mono-function timer range 80.21 - ON pulse, multi-voltage 80.41 - Signal OFF delay, multi-voltage 80.91 - Asymmetrical recycling, multi-voltage 17.5 mm wide Six time scales from 0.1s to 24h * High input/output isolation * 35 mm rail (EN 60715) mount * "Blade + cross" - both flat blade and cross head screw drivers can be used to adjust the range and function selectors, the timing trimmer, and to disengage the rail mounting clip * New multi-voltage versions with "PWM clever" technology * * * * Multi-voltage Mono-function * * Multi-voltage Mono-function BE: Signal OFF delay DI: ON pulse 80.21 / 80.41 / 80.91 Screw terminal 80.21 80.41 80.91 FOR UL HORSEPOWER AND PILOT DUTY RATINGS SEE "General technical information" page V * * Multi-voltage Mono-function LI: Asymmetrical recycling (ON starting) LE: Signal asymmetrical recycling (ON starting) Wiring diagram (without signal START) Wiring diagram (with signal START) Wiring diagram Wiring diagram (without signal (with signal START) START) 1 CO (SPDT) 1 CO (SPDT) 1 CO (SPDT) 16/30 16/30 16/30 250/400 250/400 250/400 4,000 4,000 4,000 Contact specification Contact configuration Rated current/Maximum peak current A Rated voltage/Maximum switching voltage V AC Rated load AC1 VA Rated load AC15 (230 V AC) Single phase motor rating (230 V AC) Breaking capacity DC1: 30/110/220 V Minimum switching load VA 750 750 750 kW 0.55 0.55 0.55 16/0.3/0.12 16/0.3/0.12 16/0.3/0.12 500 (10/5) 500 (10/5) 500 (10/5) AgCdO AgCdO AgCdO 24...240 24...240 12...240 A mW (V/mA) Standard contact material Supply specification Nominal voltage (UN) V AC (50/60 Hz) 24...240 24...240 12...240 Rated power AC/DC VA (50 Hz)/W < 1.8 / < 1 < 1.8 / < 1 < 1.8 / < 1 AC (17...265)V (17...265)V (10.8...265)V DC (17...265)V (17...265)V (10.8...265)V V DC Operating range Technical data (0.1...2)s, (1...20)s, (0.1...2)min, (1...20)min, (0.1...2)h, (1...24)h Specified time range Repeatability % 1 1 1 Recovery time ms 50 50 50 Minimum control impulse ms -- 50 50 % 5 5 5 100*103 100*103 100*103 -10...+50 -10...+50 -10...+50 IP 20 IP 20 IP 20 Setting accuracy-full range Electrical life at rated load in AC1 Ambient temperature range Protection category Approvals (according to type) 2 cycles C 80 Series - Modular Solid State timer (SST) 1 A Features 80.71 Multi-function and multi-voltage solid-state output timer 17.5 mm wide Six time scales from 0.1s to 24h * High input/output isolation * 35 mm rail (EN 60715) mount * Multi-voltage output (24...240 V AC/DC), independent from the input voltage * "Blade + cross" - both flat blade and cross head screw drivers can be used to adjust the range and function selectors, the timing trimmer, and to disengage the rail mounting clip * Multi-voltage input with "PWM clever" technology * * * * Multi-voltage Multi-function AI: ON delay DI: ON pulse SW: Symmetrical recycling: ON start BE: Signal OFF delay CE: Signal ON and OFF delay DE: Signal ON pulse 80.71 Screw terminal Wiring diagram (with signal START) Wiring diagram (without signal START) Output circuit 1 NO (SPST-NO) Contact configuration 1 Rated current A Rated voltage V AC/DC 24...240 Switching voltage range V AC/DC 19...265 Rated load AC15 A 1 Rated load DC1 A 1 Minimum switching current mA 0.5 Max. "OFF-state" leakage current mA 0.05 Max. "ON-state" voltage drop V 2.8 Input circuit Nominal voltage (UN) V AC (50/60 Hz) 24...240 V DC 24...240 VA (50 Hz)/W 1.3/1.3 Rated power Operating range AC (19...265)V DC (19...265)V Technical data (0.1...2)s, (1...20)s, (0.1...2)min, (1...20)min, (0.1...2)h, (1...24)h Specified time range Repeatability % 1 Recovery time ms 50 Minimum control impulse ms 50 % 5 Setting accuracy-full range Electrical life Ambient temperature range Protection category cycles C 100*106 -20...+50 IP 20 Approvals (according to type) 3 80 Series - Modular timers 6 - 8 A Features 80.61 80.82 Mono-function timer range 80.61 - True OFF delay, multi-voltage 80.82 - Star-Delta timer, multi-voltage 17.5 mm wide Rotary range selector, and timing trimmer * Four time scales from 0.1s to 20s (type 80.61) * Six time scales from 0.1s to 20min (type 80.82) * High input/output isolation * 35 mm rail (EN 60715) mount * * * * Multi-voltage Mono-function Multi-voltage Mono-function * Transfer time can be regulated (0.05...1)s * * 80.61 / 80.82 Screw terminal BI: True Off Delay 80.61 SD: Star-Delta 80.82 FOR UL HORSEPOWER AND PILOT DUTY RATINGS SEE "General technical information" page V Wiring diagram (without signal START) Wiring diagram (without signal START) 1 CO (SPDT) 2 NO (DPST-NO) 8/15 6/10 Contact specification Contact configuration Rated current/Maximum peak current A Rated voltage/Maximum switching voltage V AC Rated load AC1 Rated load AC15 (230 V AC) Single phase motor rating (230 V AC) Breaking capacity DC1: 30/110/220 V Minimum switching load 250/400 250/400 VA 2,000 1,500 VA 400 300 kW 0.3 -- 8/0.3/0.12 6/0.2/0.12 300 (5/5) 500 (12/10) AgNi AgNi 24...240 12...240 A mW (V/mA) Standard contact material Supply specification Nominal voltage (UN) V AC (50/60 Hz) Rated power AC/DC VA (50 Hz)/W 24...240 12...240 < 0.6/ < 0.6 < 1.3/ < 0.8 AC (17...265)V (10.2...265)V DC (17...265)V (10.2...265)V (0.1...1)s, (0.5...5)s, (1...10)s, (2...20)s (0.1...2)s, (1...20)s, (0.1...2)min, (1...20)min V DC Operating range Technical data Specified time range Repeatability % 1 1 Recovery time ms 50 50 Minimum control impulse ms 300 (A1-A2) -- Setting accuracy-full range Electrical life at rated load in AC1 Ambient temperature range Protection category Approvals (according to type) 4 % cycles C 5 5 100*103 60*103 -10...+50 -10...+50 IP 20 IP 20 80 Series - Modular timers 1 - 6 - 8 - 16 A Ordering information Example: 80 series, modular timers, 1 CO (SPDT) - 16 A, supply rated at (12...240)V AC/DC. 8 0 . 0 1 . 0 . 2 4 0 . 0 Series 0 0 0 Versions 0 = Standard 2 = Standard (for type 80.61 only) Type 0 = Multi-function (AI, DI, SW, BE, CE, DE) 1 = ON delay (AI) 2 = ON pulse (DI) 4 = Signal OFF delay (BE) 6 = True OFF delay (BI) 7 = Multi-function with solid state output (AI, DI, SW, BE, CE, DE) 8 = Star-Delta (SD) 9 = Asymmetrical recycling ON starting (LI, LE) Supply voltage 240 = (12 ... 240)V AC/DC (80.01, 80.82, 80.91) 240 = (24 ... 240)V AC/DC (80.11, 80.21, 80.41, 80.61, 80.71) Supply version 0 = AC (50/60 Hz)/DC No. of poles 1 = 1 CO (SPDT) 1 = 1 NO (SPST-NO), type 80.71 only 2 = 2 NO (DPST-NO), type 80.82 only Technical data Insulation 80.01/11/21/41/82/91 Dielectric strength 80.61/71 between input and output circuit V AC 4,000 2,500 between open contacts V AC 1,000 1,000 Insulation (1.2/50 s) between input and output kV 6 4 EMC specifications Type of test Reference standard Electrostatic discharge contact discharge EN 61000-4-2 4 kV air discharge EN 61000-4-2 8 kV Radio-frequency electromagnetic field (80 / 1000 MHz) EN 61000-4-3 Fast transients (burst) (5-50 ns, 5 kHz) on Supply terminals EN 61000-4-4 Surges (1.2/50 s) on Supply terminals on start terminal (B1) 10 V/m 4 kV common mode EN 61000-4-5 4 kV differential mode EN 61000-4-5 4 kV common mode EN 61000-4-5 4 kV differential mode EN 61000-4-5 4 kV Radio-frequency common mode (0.15 / 80 MHz) on Supply terminals EN 61000-4-6 10 V Radiated and conducted emission EN 55022 class B Other data Current absorption on signal control (B1) Power lost to the environment Screw torque Max. wire size < 1 mA without contact current W 1.4 with rated current W 3.2 Nm 0.8 solid cable stranded cable mm2 1x6 / 2x4 1x4 / 2x2.5 AWG 1x10 / 2x12 1x12 / 2x14 Accessories Sheet of marker tags, for types 80.61/82, plastic, 24 tags, 9x17 mm 020.24 Sheet of marker tags, for types 80.01/11/21/41/71, plastic, 72 tags, 6x12 mm 060.72 020.24 060.72 5 80 Series - Modular timers 1 - 6 - 8 - 16 A Functions U = Supply voltage LED* Supply voltage NO output contact OFF Closed Open 15 - 18 15 - 16 ON Open 15 - 18 15 - 16 ON Open (Timing in Progress) 15 - 18 15 - 16 ON Closed 15 - 16 15 - 18 S = Signal switch = Output contact Contacts Open * The LED on type 80.61 is illuminated only when the supply voltage is applied to the timer; during the timing period the LED is not illuminated. Without signal Start = Start via contact in supply line (A1). With signal Start = Start via contact into control terminal (B1). Wiring diagram Without signal START Type 80.01 80.71 (AI) ON delay. Apply power to timer. Output contacts transfer after preset time has elapsed. Reset occurs when power is removed. (DI) ON pulse. Apply power to timer. Output contacts transfer immediately. After the preset time has elapsed, contacts reset. 80.01 (SW) Symmetrical recycling: ON start. Apply power to timer. Output contacts transfer immediately and cycle between ON and OFF for as long as power is applied. The ratio is 1:1 (time on = time off). 80.71 With signal START 80.01 80.71 80.01 80.71 (BE) Signal OFF delay. Power is permenently applied to the timer. The output contacts transfer immediately on closure of the Signal Switch (S). Opening the Signal Switch initiates the preset delay, after which time the output contacts reset. (CE) Signal ON and OFF delay. Power is permenently applied to the timer. Closing the Signal Switch (S) initiates the preset delay, after which time the output contacts transfer. Opening the Signal switch initiates the same preset delay, after which time the output contacts reset. (DE) Signal ON pulse. Power is permenently applied to the timer. On momentary or maintained closure of Signal Switch (S), the output contacts transfer, and remain so for the duration of the preset delay, after which they reset. NOTE: The function must be set before energising the timer. * Possible to control an external load, such as another relay coil or timer, connected to the signal start terminal B1. * With DC supply, positive polarity has to be connected to B1 terminal (according to EN 60204-1). ** A voltage other than the supply voltage can be applied to the command Start (B1), example: A1 - A2 = 230 V AC B1 - A2 = 12 V DC 6 80 Series - Modular timers 6 - 8 - 16 A Functions Wiring diagram Without signal START 80.11/21/61 Type 80.11 (AI) ON delay. Apply power to timer. Output contacts transfer after preset time has elapsed. Reset occurs when power is removed. 80.21 (DI) ON pulse. Apply power to timer. Output contacts transfer immediately. After the preset time has elapsed, contacts reset. 80.61 (BI) True OFF delay (power OFF). Apply power to timer (minimum 300ms). Output contacts transfer immediately. Removal of power initiates the preset delay, after which time the output contacts reset. 80.82 (SD) Star - delta. Apply power to timer. The star contact ( ) closes immediately. After preset delay has elapsed the star contact ( ) resets. After a further transfer time variable from (0.05...1)s the delta contact ( ) closes and remains in that position, until reset on power off. 80.41 (BE) Signal OFF delay. Power is permenently applied to the timer. The output contacts transfer immediately on closure of the Signal Switch (S). Opening the Signal Switch initiates the preset delay, after which time the output contacts reset. 80.91 (LI) Asymmetrical recycling (ON start). Apply power to timer. Output contacts transfer immediately and cycle between ON and OFF for as long as power is applied. The ON (T1) and OFF (T2) times are independently adjustable. 80.82 With signal START 80.41 Without signal START 80.91 With signal START (LE) Signal asymmetrical recycling (ON start) Power is permenently applied to the timer. Closing Signal Switch (S) causes the output contacts to transfer immediately and cycle between ON (T1) and OFF (T2), until opened. 80.91 * Possible to control an external load, such as another relay coil or timer, connected to the signal start terminal B1. * With DC supply, positive polarity has to be connected to B1 terminal (according to EN 60204-1). ** A voltage other than the supply voltage can be applied to the command Start (B1), example: A1 - A2 = 230 V AC B1 - A2 = 12 V DC 7