80.01 80.11
1 CO (SPDT) 1 CO (SPDT)
16/30 16/30
250/400 250/400
4,000 4,000
750 750
0.55 0.55
16/0.3/0.12 16/0.3/0.12
500 (10/5) 500 (10/5)
AgCdO AgCdO
12…240 24...240
12…240 24...240
< 1.8 / < 1 < 1.8 / < 1
(10.8...265)V (17...265)V
(10.8...265)V (17...265)V
(0.1…2)s, (1…20)s, (0.1…2)min, (1…20)min, (0.1…2)h, (1…24)h
± 1 ± 1
50 50
50
± 5 ± 5
100·103100·103
–10…+50 –10…+50
IP 20 IP 20
Wiring diagram
(without signal START)
Multi-voltage
Mono-function
Multi-voltage
Multi-function
AI: ON delay
DI: ON pulse
SW: Symmetrical recycling: ON start
BE: Signal OFF delay
CE: Signal ON and OFF delay
DE: Signal ON pulse
AI: ON delay
Wiring diagram
(with signal START)
Wiring diagram
(without signal START)
Contact specification
Contact configuration
Rated current/Maximum peak current A
Rated voltage/Maximum switching voltage V AC
Rated load AC1 VA
Rated load AC15 (230 V AC) VA
Single phase motor rating (230 V AC) kW
Breaking capacity DC1: 30/110/220 V A
Minimum switching load mW (V/mA)
Standard contact material
Supply specification
Nominal voltage (UN) V AC (50/60 Hz)
V DC
Rated power AC/DC VA (50 Hz)/W
Operating range AC
DC
Technical data
Specified time range
Repeatability %
Recovery time ms
Minimum control impulse ms
Setting accuracy-full range %
Electrical life at rated load in AC1 cycles
Ambient temperature range °C
Protection category
Approvals (according to type)
1
Features
Multi-function and mono-function timer range
80.01 - Multi-function & multi-voltage
80.11 - ON delay, multi-voltage
17.5 mm wide
Six time scales from 0.1s to 24h
High input/output isolation
35 mm rail (EN 60715) mount
“Blade + cross” - both flat blade and cross head
screw drivers can be used to adjust the range
and function selectors, the timing trimmer, and
to disengage the rail mounting clip
New multi-voltage versions with “PWM clever”
technology
80.01 80.11
80.01 / 80.11
Screw terminal
FOR UL HORSEPOWER AND PILOT DUTY RATINGS
SEE “General technical information” page V
80 Series - Modular timers 16 A
80.21 80.41 80.91
Multi-voltage
Mono-function
LI: Asymmetrical recycling
(ON starting)
LE: Signal asymmetrical recycling
(ON starting)
Wiring diagram
(without signal
START)
Wiring diagram
(with signal
START)
1 CO (SPDT) 1 CO (SPDT) 1 CO (SPDT)
16/30 16/30 16/30
250/400 250/400 250/400
4,000 4,000 4,000
750 750 750
0.55 0.55 0.55
16/0.3/0.12 16/0.3/0.12 16/0.3/0.12
500 (10/5) 500 (10/5) 500 (10/5)
AgCdO AgCdO AgCdO
24...240 24...240 12...240
24...240 24...240 12...240
< 1.8 / < 1 < 1.8 / < 1 < 1.8 / < 1
(17...265)V (17...265)V (10.8...265)V
(17...265)V (17...265)V (10.8...265)V
(0.1…2)s, (1…20)s, (0.1…2)min, (1…20)min, (0.1…2)h, (1…24)h
± 1 ± 1 ± 1
50 50 50
—5050
± 5 ± 5 ± 5
100·103100·103100·103
–10…+50 –10…+50 –10…+50
IP 20 IP 20 IP 20
Multi-voltage
Mono-function
DI: ON pulse
Wiring diagram
(without signal START)
Contact specification
Contact configuration
Rated current/Maximum peak current A
Rated voltage/Maximum switching voltage V AC
Rated load AC1 VA
Rated load AC15 (230 V AC) VA
Single phase motor rating (230 V AC) kW
Breaking capacity DC1: 30/110/220 V A
Minimum switching load mW (V/mA)
Standard contact material
Supply specification
Nominal voltage (UN) V AC (50/60 Hz)
V DC
Rated power AC/DC VA (50 Hz)/W
Operating range AC
DC
Technical data
Specified time range
Repeatability %
Recovery time ms
Minimum control impulse ms
Setting accuracy-full range %
Electrical life at rated load in AC1 cycles
Ambient temperature range °C
Protection category
Approvals (according to type)
Features
Mono-function timer range
80.21 - ON pulse, multi-voltage
80.41 - Signal OFF delay, multi-voltage
80.91 - Asymmetrical recycling, multi-voltage
17.5 mm wide
Six time scales from 0.1s to 24h
High input/output isolation
35 mm rail (EN 60715) mount
“Blade + cross” - both flat blade and cross head
screw drivers can be used to adjust the range
and function selectors, the timing trimmer, and
to disengage the rail mounting clip
New multi-voltage versions with “PWM clever”
technology
80.21 80.41 80.91
80.21 / 80.41 / 80.91
Screw terminal
FOR UL HORSEPOWER AND PILOT DUTY RATINGS
SEE “General technical information” page V
Wiring diagram
(with signal START)
Multi-voltage
Mono-function
BE: Signal OFF delay
2
80 Series - Modular timers 16 A
80.71
3
Features
Multi-function and multi-voltage solid-state
output timer
17.5 mm wide
Six time scales from 0.1s to 24h
High input/output isolation
35 mm rail (EN 60715) mount
Multi-voltage output (24...240 V AC/DC),
independent from the input voltage
“Blade + cross” - both flat blade and cross head
screw drivers can be used to adjust the range
and function selectors, the timing trimmer, and
to disengage the rail mounting clip
Multi-voltage input with “PWM clever” technology
1 NO (SPST-NO)
1
24...240
19...265
1
1
0.5
0.05
2.8
24...240
24…240
1.3/1.3
(19...265)V
(19...265)V
(0.1...2)s, (1...20)s, (0.1...2)min, (1...20)min, (0.1...2)h, (1...24)h
± 1
50
50
± 5
100·106
–20…+50
IP 20
Multi-voltage
Multi-function
Output circuit
Contact configuration
Rated current A
Rated voltage V AC/DC
Switching voltage range V AC/DC
Rated load AC15 A
Rated load DC1 A
Minimum switching current mA
Max. “OFF-state” leakage current mA
Max. “ON-state” voltage drop V
Input circuit
Nominal voltage (UN) V AC (50/60 Hz)
V DC
Rated power VA (50 Hz)/W
Operating range AC
DC
Technical data
Specified time range
Repeatability %
Recovery time ms
Minimum control impulse ms
Setting accuracy-full range %
Electrical life cycles
Ambient temperature range °C
Protection category
Approvals (according to type)
AI: ON delay
DI: ON pulse
SW: Symmetrical recycling: ON start
BE: Signal OFF delay
CE: Signal ON and OFF delay
DE: Signal ON pulse
80.71
Screw terminal
Wiring diagram
(without signal START)
Wiring diagram
(with signal START)
80 Series - Modular Solid State timer (SST) 1 A
80.61 80.82
80.61 80.82
4
Wiring diagram
(without signal START)
Multi-voltage
Mono-function
Transfer time can be regulated (0.05…1)s
SD: Star-Delta
Features
Mono-function timer range
80.61 - True OFF delay, multi-voltage
80.82 - Star-Delta timer, multi-voltage
17.5 mm wide
Rotary range selector, and timing trimmer
Four time scales from 0.1s to 20s (type 80.61)
Six time scales from 0.1s to 20min (type 80.82)
High input/output isolation
35 mm rail (EN 60715) mount
1 CO (SPDT) 2 NO (DPST-NO)
8/15 6/10
250/400 250/400
2,000 1,500
400 300
0.3
8/0.3/0.12 6/0.2/0.12
300 (5/5) 500 (12/10)
AgNi AgNi
24...240 12...240
24…240 12...240
< 0.6/ < 0.6 < 1.3/ < 0.8
(17...265)V (10.2...265)V
(17...265)V (10.2...265)V
(0.1...1)s, (0.5...5)s, (1...10)s, (2...20)s (0.1...2)s, (1...20)s, (0.1...2)min, (1...20)min
± 1 ± 1
50 50
300 (A1-A2)
± 5 ± 5
100·10360·103
–10…+50 –10…+50
IP 20 IP 20
Multi-voltage
Mono-function
Contact specification
Contact configuration
Rated current/Maximum peak current A
Rated voltage/Maximum switching voltage V AC
Rated load AC1 VA
Rated load AC15 (230 V AC) VA
Single phase motor rating (230 V AC) kW
Breaking capacity DC1: 30/110/220 V A
Minimum switching load mW (V/mA)
Standard contact material
Supply specification
Nominal voltage (UN) V AC (50/60 Hz)
V DC
Rated power AC/DC VA (50 Hz)/W
Operating range AC
DC
Technical data
Specified time range
Repeatability %
Recovery time ms
Minimum control impulse ms
Setting accuracy-full range %
Electrical life at rated load in AC1 cycles
Ambient temperature range °C
Protection category
Approvals (according to type)
BI: True Off Delay
Wiring diagram
(without signal START)
80.61 / 80.82
Screw terminal
FOR UL HORSEPOWER AND PILOT DUTY RATINGS
SEE “General technical information” page V
80 Series - Modular timers 6 - 8 A
Example: 80 series, modular timers, 1 CO (SPDT) - 16 A, supply rated at (12…240)V AC/DC.
Versions
0 = Standard
2 = Standard (for type 80.61 only)
Supply voltage
240 = (12 ... 240)V AC/DC (80.01, 80.82, 80.91)
240 = (24 ... 240)V AC/DC (80.11, 80.21, 80.41, 80.61, 80.71)
Supply version
0 = AC (50/60 Hz)/DC
No. of poles
1 = 1 CO (SPDT)
1 = 1 NO (SPST-NO), type 80.71 only
2 = 2 NO (DPST-NO), type 80.82 only
Series
Type
0 = Multi-function (AI, DI, SW, BE, CE, DE)
1 = ON delay (AI)
2 = ON pulse (DI)
4 = Signal OFF delay (BE)
6 = True OFF delay (BI)
7 = Multi-function with solid state output
(AI, DI, SW, BE, CE, DE)
8 = Star-Delta (SD)
9 = Asymmetrical recycling ON starting (LI, LE)
0 1 0 00 0 0
Ordering information
... .
24080
Insulation
Dielectric strength 80.01/11/21/41/82/91 80.61/71
between input and output circuit V AC 4,000 2,500
between open contacts V AC 1,000 1,000
Insulation (1.2/50 µs) between input and output kV 6 4
EMC specifications
Type of test Reference standard
Electrostatic discharge contact discharge EN 61000-4-2 4 kV
air discharge EN 61000-4-2 8 kV
Radio-frequency electromagnetic field (80 ÷ 1000 MHz) EN 61000-4-3 10 V/m
Fast transients (burst) (5-50 ns, 5 kHz) on Supply terminals EN 61000-4-4 4 kV
Surges (1.2/50 µs) on Supply terminals common mode EN 61000-4-5 4 kV
differential mode EN 61000-4-5 4 kV
on start terminal (B1) common mode EN 61000-4-5 4 kV
differential mode EN 61000-4-5 4 kV
Radio-frequency common mode (0.15 ÷ 80 MHz) on Supply terminals EN 61000-4-6 10 V
Radiated and conducted emission EN 55022 class B
Other data
Current absorption on signal control (B1) < 1 mA
Power lost to the environment without contact current W 1.4
with rated current W 3.2
Screw torque Nm 0.8
Max. wire size solid cable stranded cable
mm2 1x6 / 2x4 1x4 / 2x2.5
AWG 1x10 / 2x12 1x12 / 2x14
Technical data
Accessories
Sheet of marker tags, for types 80.61/82, plastic, 24 tags, 9x17 mm 020.24
80 Series - Modular timers 1 - 6 - 8 - 16 A
5
Sheet of marker tags, for types 80.01/11/21/41/71, plastic, 72 tags, 6x12 mm 060.72
020.24
060.72
(AI) ON delay.
Apply power to timer. Output contacts transfer after preset
time has elapsed. Reset occurs when power is removed.
(DI) ON pulse.
Apply power to timer. Output contacts transfer immediately.
After the preset time has elapsed, contacts reset.
(SW) Symmetrical recycling: ON start.
Apply power to timer. Output contacts transfer immediately
and cycle between ON and OFF for as long as power is
applied. The ratio is 1:1 (time on = time off).
(BE) Signal OFF delay.
Power is permenently applied to the timer. The output
contacts transfer immediately on closure of the Signal
Switch (S). Opening the Signal Switch initiates the preset
delay, after which time the output contacts reset.
(DE) Signal ON pulse.
Power is permenently applied to the timer.
On momentary or maintained closure of Signal Switch (S),
the output contacts transfer, and remain so for the duration
of the preset delay, after which they reset.
(CE) Signal ON and OFF delay.
Power is permenently applied to the timer. Closing the
Signal Switch (S) initiates the preset delay, after which time
the output contacts transfer. Opening the Signal switch
initiates the same preset delay, after which time the output
contacts reset.
Functions
With signal START
Without signal START Type
80.01
80.71
Contacts
NO output contact
Supply voltage
LED*
OFF
ON
ON
ON
U= Supply voltage
S= Signal switch
= Output contact Open
Open
Open
(Timing in Progress)
Closed
15 - 18
15 - 18
15 - 18
15 - 16
15 - 16
15 - 16
15 - 16
15 - 18
Open Closed
* The LED on type 80.61 is illuminated only when the supply voltage is applied to the timer; during the timing period
the LED is not illuminated.
80 Series - Modular timers 1 - 6 - 8 - 16 A
6
NOTE: The function must be set before energising the timer.
• Possible to control an external load, such as another relay coil or timer, connected to the signal start terminal B1.
* With DC supply, positive polarity has to be connected to B1 terminal (according to EN 60204-1).
** A voltage other than the supply voltage can be applied to the command Start (B1), example:
A1 - A2 = 230 V AC
B1 - A2 = 12 V DC
Wiring diagram
80.01
80.71
80.71
80.01
80.71
80.01
Without signal Start = Start via contact in supply line (A1).
With signal Start = Start via contact into control terminal (B1).
Functions
80 Series - Modular timers 6 - 8 - 16 A
(AI) ON delay.
Apply power to timer. Output contacts transfer after preset
time has elapsed. Reset occurs when power is removed.
(DI) ON pulse.
Apply power to timer. Output contacts transfer immediately.
After the preset time has elapsed, contacts reset.
(BE) Signal OFF delay.
Power is permenently applied to the timer.
The output contacts transfer immediately on closure of the
Signal Switch (S). Opening the Signal Switch initiates the
preset delay, after which time the output contacts reset.
(LI) Asymmetrical recycling (ON start).
Apply power to timer. Output contacts transfer immediately
and cycle between ON and OFF for as long as power is
applied. The ON (T1) and OFF (T2) times are independently
adjustable.
(LE) Signal asymmetrical recycling (ON start)
Power is permenently applied to the timer.
Closing Signal Switch (S) causes the output contacts to
transfer immediately and cycle between ON (T1) and
OFF (T2), until opened.
Without signal START
With signal START
Without signal START
80.11/21/61
80.82
80.21
80.61
80.82
80.41
80.41
80.91
With signal START
80.91
(BI) True OFF delay (power OFF).
Apply power to timer (minimum 300ms). Output contacts
transfer immediately. Removal of power initiates the preset
delay, after which time the output contacts reset.
(SD) Star - delta.
Apply power to timer. The star contact ( ) closes immediately.
After preset delay has elapsed the star contact ( ) resets.
After a further transfer time variable from (0.05…1)s the delta
contact ( Δ) closes and remains in that position, until reset on
power off.
7
Wiring diagram
Type
80.11
80.91
• Possible to control an external load, such as another relay coil or timer, connected to the signal start terminal B1.
* With DC supply, positive polarity has to be connected to B1 terminal (according to EN 60204-1).
** A voltage other than the supply voltage can be applied to the command Start (B1), example:
A1 - A2 = 230 V AC
B1 - A2 = 12 V DC