ADDITIONAL SPECIFICATIONS
The above models are available in ‘A, B and G’ housings.
Custom housings and electrical specifications are also
available. Contact factory for details.
Phase variation is measured at center frequency and 25°C.
Add ±3° over operating temperature of -40 to +85°C.
Output power is 10 dBm nominal at center frequency
and 25°C.
Additional output power variation of ±1 dB will occur over
operating temperature of -40 to +85°C.
Input/output impedance is 50 .
Input VSWR is < 1.5:1 typical.
Output VSWR is < 2.0:1 typical.
Noise figure is typically less than 15 dB at center frequency
and 25°C.
Power: -12 VDC at 150 mA typical.
ORDER OPTIONS
For -15 VDC, add suffix “C”.
Matching up to three channels to within ±3° at 25°C is
available. Contact factory for details.
Typical part number: LCPM-16040-70BC (for ‘B’ housing
at -15 VDC).
LCPM-3010-70 30 10 -70 to 0 0.5 3
LCPM-6020-70 60 20 -70 to 0 0.5 3
LCPM-7030-70 70 30 -70 to 0 0.5 3
LCPM-12020-70 120 20 -65 to +5 0.5 5
LCPM-14040-70 140 40 -65 to +5 1 5
LCPM-16040-70 160 40 -65 to +5 1 5
LCPM-200100-70 200 100 -65 to +5 15
LCPM-400100-60 400 100 -60 to 0 1 5
CENTER 3 dB DYNAMIC OUTPUT POWER PHASE
MODEL FREQUENCY BANDWIDTH RANGE VARIATION VARIATION
NUMBER (MHz) (dBm) (dBm) (±dB) (±Deg.)
CONSTANT PHASE-LIMITING AMPLIFIERS
MODEL: LCPM SERIES
FEATURES
Up to 70 dB dynamic range
±3° phase variation
±5 dB amplitude variation
Fast recovery
OPTIONS
Customized center frequencies
Custom packaging
High-reliability screening
Matched sets
TYPICAL PHASE RESPONSE
VS. INPUT POWER
TYPICAL TEST DATA
100 Davids Drive, Hauppauge, NY 11788 • TEL: (631) 439-9220 • FAX: (631) 436-7430 • www.miteq.com
C-17B/17 08-14-07
NOTE: FOR MODIFICATION OF OUR STANDARD MODELS, PLEASE CONSULT FACTORY.
LCPM SERIES OUTLINE DRAWINGS
OUTLINE A
OUTLINE B
OUTLINE G
100 Davids Drive, Hauppauge, NY 11788 • TEL: (631) 439-9220 • FAX: (631) 436-7430 • www.miteq.com
C-17B/18 08-14-07
NOTE: DIMENSIONS SHOWN IN BRACKETS [ ] ARE IN MILLIMETERS.