AZ2100
1/17/01W
GENERAL DATA
Life Expectancy Minimum operations
Mechanical 1 x 107
Electrical 1 x 105at 30 A 120 VAC Res. (N.O.)
Operate Time (max.) Max. 12 ms
Typical: 8 ms
Release Time (max.) Max. 5 ms
Typical: 3.5 ms
Dielectric Strength Group A: 2500 Vrms contact to coil
(at sea level for 1 min.) Group B: 2000 Vrms contact to coil
1500 Vrms between open contacts
Insulation Resistance 100 megohms min. at 500 VDC, 20°C,
50% RH
Dropout Greater than 10% of nominal coil voltage
Ambient Temperature
Operating -55°C (-67°F) to 100°C (212°F) Class B
-55°C (-67°F) to 125°C (257°F) Class F
Storage -55°C (-67°F) to 130°C (266°F) Class B
-55°C (-67°F) to 155°C (311°F) Class F
Vibration 0.062" DA at 10–55 Hz
Shock 20 g
Enclosure P. B.T. polyester
Terminals Tinned copper alloy, P.C. with quick-con-
nect tabs, .250" wide, on top
Max. Solder Temp. 270°C (518°F)
Max. Solder Time 5 seconds
Max. Solvent Temp. 80°C (176°F)
Max. Immersion Time 30 seconds
Weight 43 grams
MINIATURE
POWER RELAY
FEATURES
Versatility of both PC and “Trace-Saver” quick-connect
terminals on contacts
30 Amp switching capability for both N.O. and
N.C. contacts
1 Form A, B and C contacts available
DC coils to 120 VDC
Life expectancy to 10 million operations
Class B insulation for high temperature applications
Class F (155°C) versions available
Available with an epoxy seal for automatic wave
soldering and immersion cleaning
UL, CUR file E44211 including versions meeting
UL 508 and UL 873 spacing and contact
rating requirements
CONTACTS
Arrangement SPDT (1 Form C)
SPST (1 Form A and 1 Form B)
Ratings Resistive load:
Max. switched power: 900 W or 7200 VA
Max. switched current: 30 A
Max. switched voltage: 30 VDC or 300 VAC
UL Rating: See chart for UL contact ratings.
AZ2100 Series meets UL 508 Group A spacing
requirements. AZ2101 Series meets UL 508
Group B spacing requirements.
Material Silver cadmium oxide
Resistance < 20 milliohms initially
(at rated current, voltage drop method)
COIL
Power
At Pickup Voltage 500 mW
(typical)
Max. Continuous 2.2 W at 20°C (68°F) ambient
Dissipation 1.8 W at 40°C (104°F) ambient
Temperature Rise 38°C (68°F) at nominal coil voltage
Temperature Max. 130°C (266°F) Class B
Max. 155°C (311°F) Class F NOTES
1. All values at 20°C (68°F).
2. Relay may pull in with less than “Must Operate” value.
3. Unsealed relays should not be dip cleaned.
4. Other coil resistances and sensitivities available upon request.
5. Specifications subject to change without notice.
RELAY ORDERING DATA: UL 508 Group A; UL 873 Version
STANDARD RELAYS: 1 Form A (SPST N.O.)
COIL SPECIFICATIONS ORDER NUMBER*
Nominal Coil Max. Continuous Coil Resistance Must Operate Unsealed Sealed
VDC VDC ±10% VDC
5 7.3 27 3.75 AZ2100–1A–5D AZ2100–1A–5DE
6 8.9 40 4.5 AZ2100–1A–6D AZ2100–1A–6DE
9 13.9 97 6.75 AZ2100–1A–9D AZ2100–1A–9DE
12 17.5 155 9.0 AZ2100–1A–12D AZ2100–1A–12DE
15 22.5 256 11.25 AZ2100–1A–15D AZ2100–1A–15DE
18 27.4 380 13.5 AZ2100–1A–18D AZ2100–1A–18DE
24 36.1 660 18.0 AZ2100–1A–24D AZ2100–1A–24DE
48 68.4 2,560 36.0 AZ2100–1A–48D AZ2100–1A–48DE
70 104.4 5,500 52.5 AZ2100–1A–70D AZ2100–1A–70DE
110 163.2 13,450 82.5 AZ2100–1A–110D AZ2100–1A–110DE
STANDARD RELAYS: 1 Form C (SPDT)
COIL SPECIFICATIONS ORDER NUMBER*
Nominal Coil Max. Continuous Coil Resistance Must Operate Unsealed Sealed
VDC VDC ±10% VDC
5 7.3 27 3.75 AZ2100–1C–5D AZ2100–1C–5DE
6 8.9 40 4.5 AZ2100–1C–6D AZ2100–1C–6DE
9 13.9 97 6.75 AZ2100–1C–9D AZ2100–1C–9DE
12 17.5 155 9.0 AZ2100–1C–12D AZ2100–1C–12DE
15 22.5 256 11.25 AZ2100–1C–15D AZ2100–1C–15DE
18 27.4 380 13.5 AZ2100–1C–18D AZ2100–1C–18DE
24 36.1 660 18.0 AZ2100–1C–24D AZ2100–1C–24DE
48 68.4 2,560 36.0 AZ2100–1C–48D AZ2100–1C–48DE
70 104.4 5,500 52.5 AZ2100–1C–70D AZ2100–1C–70DE
110 163.2 13,450 82.5 AZ2100–1C–110D AZ2100–1C–110DE
*Substitute “1B” in place of “1A or 1C” to indicate 1 Form B. To indicate Class F version, add suffix “F”.
Other coil resistances and sensitivities available upon request. Please contact the factory.
AZ2100
1/17/01W
MECHANICAL DATA
I FORM A
(SPST - NO) I FORM B
(SPST - NC) I FORM C
(SPDT)
.081 x .003
(2.06 x .076)
.900
(22.84)
.300
(7.6)
.400
(10.2)
.150
(3.81)
.550
(13.96) .700
(17.77)
.043 x .003
(1.09 x .076)
DIA (3 PLACES)
DIA
.032
(0.81)
.250
(6.35)
1.27
(32.23)
1.08
(27.4)
.240
(6.1)
1.10
(27.92)
.130
(3.3)
.032 x .062
(0.81 x 1.57)
.025 x .025
(0.63 x 0.63)
.045 x .045
(1.14 x 1.14)
.140 + .01, .020
(3.6 + .25, .51)
(3 PLACES)
(3 PLACES)
WIRING DIAGRAM
PC BOARD LAYOUT
Viewed toward terminals
Viewed toward terminals
Dimensions in inches with metric equivalents in parentheses. Tolerance: ± .010"
AZ2100
1/17/01W
RELAY ORDERING DATA: UL 508 Group B
STANDARD RELAYS: 1 Form A (SPST N.O.)
COIL SPECIFICATIONS ORDER NUMBER*
Nominal Coil Max. Continuous Coil Resistance Must Operate Unsealed Sealed
VDC VDC ±10% VDC
5 7.3 27 3.75 AZ21011A5D AZ21011A5DE
6 8.9 40 4.5 AZ21011A6D AZ21011A6DE
9 13.9 97 6.75 AZ21011A9D AZ21011A9DE
12 17.5 155 9.0 AZ21011A12D AZ21011A12DE
15 22.5 256 11.25 AZ21011A15D AZ21011A15DE
18 27.4 380 13.5 AZ21011A18D AZ21011A18DE
24 36.1 660 18.0 AZ21011A24D AZ21011A24DE
48 68.4 2,560 36.0 AZ21011A48D AZ21011A48DE
70 104.4 5,500 52.5 AZ21011A70D AZ21011A70DE
110 163.2 13,450 82.5 AZ21011A110D AZ21011A110DE
STANDARD RELAYS: 1 Form C (SPDT)
COIL SPECIFICATIONS ORDER NUMBER*
Nominal Coil Max. Continuous Coil Resistance Must Operate Unsealed Sealed
VDC VDC ±10% VDC
5 7.3 27 3.75 AZ21011C5D AZ21011C5DE
6 8.9 40 4.5 AZ21011C6D AZ21011C6DE
9 13.9 97 6.75 AZ21011C9D AZ21011C9DE
12 17.5 155 9.0 AZ21011C12D AZ21011C12DE
15 22.5 256 11.25 AZ21011C15D AZ21011C15DE
18 27.4 380 13.5 AZ21011C18D AZ21011C18DE
24 36.1 660 18.0 AZ21011C24D AZ21011C24DE
48 68.4 2,560 36.0 AZ21011C48D AZ21011C48DE
70 104.4 5,500 52.5 AZ21011C70D AZ21011C70DE
110 163.2 13,450 82.5 AZ21011C110D AZ21011C110DE
*Substitute 1B in place of 1A or 1C to indicate 1 Form B. To indicate Class F version, add suffix F.
Other coil resistances and sensitivities available upon request. Please contact the factory.
MECHANICAL DATA
WIRING DIAGRAM
PC BOARD LAYOUT
I FORM A
(SPST - NO) I FORM B
(SPST - NC) I FORM C
(SPDT)
Viewed toward terminals
Viewed toward terminals
.032
(0.81)
.250
(6.35)
1.27
(32.23)
1.08
(27.4)
.240
(6.1)
1.10
(27.92)
.130
(3.3)
.032 x .062
(0.81 x 1.57)
.025 x .025
(0.63 x 0.63)
.045 x .045
(1.14 x 1.14)
.140 + .01, .020
(3.6 + .25, .51)
(3 PLACES)
(3 PLACES)
.081 x .003
(2.06 x .076)
.900
(22.84)
1.000
(25.38)
.300
(7.6)
.400
(10.2)
.150
(3.81)
.550
(13.97) .700
(17.78)
.043 x .003
(1.09 x .076)
DIA (4 PLACES)
DIA
.350
(8.89)
Dimensions in inches with metric equivalents in parentheses. Tolerance: ± .010"
UL/CUR File E44211 Approved Contact Ratings
Form A Form B Form C
Load Type Cycles Volts (NO) (NC) NO NC
General Purpose 100,000 125 or 240 VAC 30 A 15 A 15 A
(Inductive) 30,000 277 VAC 30 A 30 A 30 A 30 A
Resistive 100,000 125 or 240 VAC 30 A 15 A ——
100,000 30 VDC 20 A 10 A 20 A 10 A
100,000 277 VAC 20 A ——
100,000 * 240 VAC 15 A ——
Ballast 6,000 125, 240 or 6 A 3 A 6 A 3 A
277 VAC
Pilot Duty 30,000 125 VAC 800 VA 275 VA 470 VA 275 VA
30,000 240 VAC 690 VA 275 VA 470 VA 275 VA
100,000 125 or 277 VAC 690 VA 690 VA
Motor Load 6,000 125 VAC 1 HP 1/4HP 1 HP 1/4HP
6,000 240 VAC 2 HP 1 HP 2 HP 1 HP
30,000 125 VAC 1 HP 1 HP
100,000 125 or 277 VAC 3/4HP 3/4HP
Definite Purpose 30,000 ** 120 VAC 82.8 LRA 82.8 LRA
13.8 FLA 13.8 FLA
30,000 125 VAC 96 LRA 33 LRA 60 LRA 33 LRA
30 FLA 10 FLA 20 FLA 10 FLA
30,000 ** 125 VAC 60 LRA 30 LRA 60 LRA 30 LRA
20 FLA 12 FLA 20 FLA 12 FLA
(LRA-Locked Rotor) 100,000 125 VAC 82.8 LRA 82.8 LRA
27 FLA 27 FLA
(FLA-Full Load) 30,000 240 VAC 80 LRA 33 LRA 60 LRA 33 LRA
30 FLA 10 FLA 20 FLA 10 FLA
30,000 ** 240 VAC 41.4 LRA 41.4 LRA
6.9 FLA 6.9 FLA
100,000 277 VAC 60 LRA 60 LRA
20 FLA 20 FLA
Tungsten 6,000 125 VAC 15A 15A 3A
6,000 240 VAC 5A 5A 3A
6,000 120 VAC 3A ——
6,000 240 VAC 3A ——
TV5 25,000 120 VAC TV5TV5TV3
TV3 25,000 120 VAC TV3TV3
* Ambient temperature 96°C (208°F) max. sealed and 105°C (221°F) unsealed.
** Ambient temperature 85°C (185°F) max. sealed and unsealed.
AZ2100
1/17/01W
Coil Temperature Rise
Percent of Nominal Coil Voltage (at 20˚C)
40% 60% 80% 100% 120% 140% 160% 180% 200%
Coil Temperature Rise ˚C
180
160
140
120
100
80
60
40
20
0
0A
15A
20A
30A
25A
Maximum Switching Capacity
10 20 30 40 60 80 100 200 300
30
20
10
8
6
5
4
3
2
1
VOLTAGE
AMPERES
DC RESISTIVE
LOAD
AC RESISTIVE
LOAD